Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
- 7 December 2020
- journal article
- research article
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (3)
Abstract
Aneurysms are bulges in arteries which reflect unhealthy state of conduit in which blood is flowing. In the aorta, they are typically found in the abdominal region as well as thoracic region. Understanding the rupture risk of these vessels is critical to preventing failure and fatalities. In the current clinical practice, treatment modalities are initiated, when the out‐pouching exceeds maximum diameter (Dmax). However this approach is very crude as it does not account for the fluid mechanical forces and the attendant stresses. Since it is medically and ethically not possible to follow the patients to study the rupture risk potential, fluid structure interaction (FSI) modelling would be an apt tool to develop adequate understanding on various hemodynamic parameters. On the other hand, performing patient‐specific studies would demand adequate lead time and they are computationally expensive as well. In the present study, the shape of the aneurysm and its interaction with the flowing fluid are accounted through the shape indices to study the FSI effects on the hemodynamic parameters. Numerical simulation of Newtonian flow through five axi‐symmetric geometries with different shape indices coupled with a linear elastic vessel wall model is considered. From these simulations, it was observed that (Dmax) to height ratio (DHr) is the most significant shape index which influences the variation of all hemodynamic parameters, which makes it a potential candidate for predicting rupture risk. Wall acceleration due to pulsatile flow was found to cause the onset of re‐circulation zones at the centre of the aneurysm during early systole and the temporal deceleration resulted in the generation of near wall eddying structures during late diastole. Investigation of turbulence carried out with k‐ω Shear Stress transport turbulence model, predicts a turbulence intensity of greater than 1.5% in the diseased segment as well as the distal end of the aneurysm.Keywords
This publication has 40 references indexed in Scilit:
- CFD Modelling of Abdominal Aortic Aneurysm on Hemodynamic Loads Using a Realistic Geometry with CTComputational and Mathematical Methods in Medicine, 2013
- Comparison of patient‐specific inlet boundary conditions in the numerical modelling of blood flow in abdominal aortic aneurysm diseaseInternational Journal for Numerical Methods in Biomedical Engineering, 2012
- Patient-Based Abdominal Aortic Aneurysm Rupture Risk Prediction with Fluid Structure Interaction ModelingAnnals of Biomedical Engineering, 2010
- Three-Dimensional Geometrical Characterization of Abdominal Aortic Aneurysms: Image-Based Wall Thickness DistributionJournal of Biomechanical Engineering, 2009
- Intraluminal thrombus and risk of rupture in patient specific abdominal aortic aneurysm – FSI modellingComputer Methods in Biomechanics and Biomedical Engineering, 2009
- Abdominal Aortic Aneurysm Risk of Rupture: Patient-Specific FSI Simulations Using Anisotropic ModelJournal of Biomechanical Engineering, 2008
- Wall stress and flow dynamics in abdominal aortic aneurysms: finite element analysis vs. fluid–structure interactionComputer Methods in Biomechanics and Biomedical Engineering, 2008
- A comparison between different asymmetric abdominal aortic aneurysm morphologies employing computational fluid–structure interaction analysisEuropean Journal of Mechanics - B/Fluids, 2007
- Compliant biomechanics of abdominal aortic aneurysms: A fluid–structure interaction studyComputers & Structures, 2007
- A patient-specific computational model of fluid–structure interaction in abdominal aortic aneurysmsMedical Engineering & Physics, 2005