Nimmy Thankom Philip
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nimmy Thankom Philip has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- B. S. Varaprasad Patnaik
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras 1 , Chennai 600036
2 shared publications - Seeninaidu Nallayarasu
IIT Madras
2 shared publications - Subrata K. Bhattacharyya
Department of Ocean Engineering, Indian Institute of Technology, Madras, India
2 shared publications - Bhanu Jayanand Sudhir
Department of Neurosurgery, Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST) 2 , Thiruvananthapuram 695011, Kerala
1 shared publication - Chanikya Valeti
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras 1 , Chennai 600036
1 shared publication - Srinivas Bolem
Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, 600036, Tamil Nadu, India
1 shared publication
Latest Publications
- 20 July 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 130 (1) , 104211
Patient-specific arterial wall generation for intracranial aneurysms with a variable and a near realistic vessel wall thickness for FSI studies
Imaging methodologies such as, computed tomography (CT) aid in three-dimensional (3D) reconstruction of patient-specific aneurysms. The radiological data is useful in understanding their location, shape, size, and disease progression. However, there are serious impediments in discerning the blood vessel wall thickness due to limitations in the current imaging modalities. This further restricts the ability to perform high-fidelity fluid structure interaction (FSI) studies for an accurate assessment of rupture risk. FSI studies would require the arterial wall mesh to be generated to determine realistic maximum allowable wall stresses by performing coupled calculations for the hemodynamic forces with the arterial walls. In the present study, a novel methodology is developed to geometrically model variable vessel wall thickness for the lumen isosurface extracted from CT scan slices of patient-specific aneurysms based on clinical and histopathological inputs. FSI simulations are carried out with the reconstructed models to assess the importance of near realistic wall thickness model on rupture risk predictions. During surgery, clinicians often observe translucent vessel walls, indicating the presence of thin regions. The need to generate variable vessel wall thickness model, that embodies the wall thickness gradation, is closer to such clinical observations. Hence, corresponding FSI simulations performed can improve clinical outcomes. Considerable differences in the magnitude of instantaneous wall shear stresses and von Mises stresses in the walls of the aneurysm was observed between a uniform wall thickness and a variable wall thickness model. In the present study, a variable vessel wall thickness generation algorithm is implemented. It was shown that, a realistic wall thickness modeling is necessary for an accurate prediction of the shear stresses on the wall as well as von Mises stresses in the wall. FSI simulations are performed to demonstrate the utility of variable wall thickness modeling.
- 20 July 2024
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 130 (1) , 104211
Patient-specific arterial wall generation for intracranial aneurysms with a variable and a near realistic vessel wall thickness for FSI studies
Imaging methodologies such as, computed tomography (CT) aid in three-dimensional (3D) reconstruction of patient-specific aneurysms. The radiological data is useful in understanding their location, shape, size, and disease progression. However, there are serious impediments in discerning the blood vessel wall thickness due to limitations in the current imaging modalities. This further restricts the ability to perform high-fidelity fluid structure interaction (FSI) studies for an accurate assessment of rupture risk. FSI studies would require the arterial wall mesh to be generated to determine realistic maximum allowable wall stresses by performing coupled calculations for the hemodynamic forces with the arterial walls. In the present study, a novel methodology is developed to geometrically model variable vessel wall thickness for the lumen isosurface extracted from CT scan slices of patient-specific aneurysms based on clinical and histopathological inputs. FSI simulations are carried out with the reconstructed models to assess the importance of near realistic wall thickness model on rupture risk predictions. During surgery, clinicians often observe translucent vessel walls, indicating the presence of thin regions. The need to generate variable vessel wall thickness model, that embodies the wall thickness gradation, is closer to such clinical observations. Hence, corresponding FSI simulations performed can improve clinical outcomes. Considerable differences in the magnitude of instantaneous wall shear stresses and von Mises stresses in the walls of the aneurysm was observed between a uniform wall thickness and a variable wall thickness model. In the present study, a variable vessel wall thickness generation algorithm is implemented. It was shown that, a realistic wall thickness modeling is necessary for an accurate prediction of the shear stresses on the wall as well as von Mises stresses in the wall. FSI simulations are performed to demonstrate the utility of variable wall thickness modeling.
- 7 December 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (3)
Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
Aneurysms are bulges in arteries which reflect unhealthy state of conduit in which blood is flowing. In the aorta, they are typically found in the abdominal region as well as thoracic region. Understanding the rupture risk of these vessels is critical to preventing failure and fatalities. In the current clinical practice, treatment modalities are initiated, when the out‐pouching exceeds maximum diameter (Dmax). However this approach is very crude as it does not account for the fluid mechanical forces and the attendant stresses. Since it is medically and ethically not possible to follow the patients to study the rupture risk potential, fluid structure interaction (FSI) modelling would be an apt tool to develop adequate understanding on various hemodynamic parameters. On the other hand, performing patient‐specific studies would demand adequate lead time and they are computationally expensive as well. In the present study, the shape of the aneurysm and its interaction with the flowing fluid are accounted through the shape indices to study the FSI effects on the hemodynamic parameters. Numerical simulation of Newtonian flow through five axi‐symmetric geometries with different shape indices coupled with a linear elastic vessel wall model is considered. From these simulations, it was observed that (Dmax) to height ratio (DHr) is the most significant shape index which influences the variation of all hemodynamic parameters, which makes it a potential candidate for predicting rupture risk. Wall acceleration due to pulsatile flow was found to cause the onset of re‐circulation zones at the centre of the aneurysm during early systole and the temporal deceleration resulted in the generation of near wall eddying structures during late diastole. Investigation of turbulence carried out with k‐ω Shear Stress transport turbulence model, predicts a turbulence intensity of greater than 1.5% in the diseased segment as well as the distal end of the aneurysm.
- 7 December 2020
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 37 (3)
Fluid structure interaction study in model abdominal aortic aneurysms: Influence of shape and wall motion
Aneurysms are bulges in arteries which reflect unhealthy state of conduit in which blood is flowing. In the aorta, they are typically found in the abdominal region as well as thoracic region. Understanding the rupture risk of these vessels is critical to preventing failure and fatalities. In the current clinical practice, treatment modalities are initiated, when the out‐pouching exceeds maximum diameter (Dmax). However this approach is very crude as it does not account for the fluid mechanical forces and the attendant stresses. Since it is medically and ethically not possible to follow the patients to study the rupture risk potential, fluid structure interaction (FSI) modelling would be an apt tool to develop adequate understanding on various hemodynamic parameters. On the other hand, performing patient‐specific studies would demand adequate lead time and they are computationally expensive as well. In the present study, the shape of the aneurysm and its interaction with the flowing fluid are accounted through the shape indices to study the FSI effects on the hemodynamic parameters. Numerical simulation of Newtonian flow through five axi‐symmetric geometries with different shape indices coupled with a linear elastic vessel wall model is considered. From these simulations, it was observed that (Dmax) to height ratio (DHr) is the most significant shape index which influences the variation of all hemodynamic parameters, which makes it a potential candidate for predicting rupture risk. Wall acceleration due to pulsatile flow was found to cause the onset of re‐circulation zones at the centre of the aneurysm during early systole and the temporal deceleration resulted in the generation of near wall eddying structures during late diastole. Investigation of turbulence carried out with k‐ω Shear Stress transport turbulence model, predicts a turbulence intensity of greater than 1.5% in the diseased segment as well as the distal end of the aneurysm.
- 2 October 2013
- Published by Taylor & Francis in Ships and Offshore Structures
- Vol. 14 (4) , 396-411
Experimental investigation and CFD simulation of heave damping effects due to circular plates attached to spar hull
- 2 October 2013
- Published by Taylor & Francis in Ships and Offshore Structures
- Vol. 14 (4) , 396-411
Experimental investigation and CFD simulation of heave damping effects due to circular plates attached to spar hull
- 1 July 2012
- Published by ASME International
- p. 249-260
Damping Characteristics of Heave Plates Attached to Spar Hull
Damping elements are used in ships and offshore structures as response reduction devices for maintaining the hydrodynamic response within acceptable limits. The use of such elements so far has been based on past experience or using empirical based design approach. An investigation of the wave excitation forces acting on these structures with and without damping elements may give an insight into the damping effects of such elements. Also understanding the flow pattern and the magnitude of flow variation around these elements may be useful to improve the design methods. In the present study, measurement of damping forces and response were carried out to establish the relationship between wave frequency amplitude and damping ratio. It was observed that the damping varies with wave period non-linearly and linearly with wave height. Also it was observed that increase in added mass combined with viscous damping is a key factor for the effectiveness of heave plates in reducing motion response of spar platforms. Of the various configurations tested, the spar with double heave plate at the bottom has higher damping compared to other configurations.
- 1 July 2012
- Published by ASME International
- p. 249-260
Damping Characteristics of Heave Plates Attached to Spar Hull
Damping elements are used in ships and offshore structures as response reduction devices for maintaining the hydrodynamic response within acceptable limits. The use of such elements so far has been based on past experience or using empirical based design approach. An investigation of the wave excitation forces acting on these structures with and without damping elements may give an insight into the damping effects of such elements. Also understanding the flow pattern and the magnitude of flow variation around these elements may be useful to improve the design methods. In the present study, measurement of damping forces and response were carried out to establish the relationship between wave frequency amplitude and damping ratio. It was observed that the damping varies with wave period non-linearly and linearly with wave height. Also it was observed that increase in added mass combined with viscous damping is a key factor for the effectiveness of heave plates in reducing motion response of spar platforms. Of the various configurations tested, the spar with double heave plate at the bottom has higher damping compared to other configurations.