Noninvasive quantification of alveolar morphometry in elderly never- and ex-smokers
Open Access
- 13 October 2015
- journal article
- research article
- Published by Wiley in Physiological Reports
- Vol. 3 (10) , e12583
Abstract
Diffusion‐weighted magnetic resonance imaging (MRI) provides a way to generate in vivo lung images with contrast sensitive to the molecular displacement of inhaled gas at subcellular length scales. Here, we aimed to evaluate hyperpolarized 3He MRI estimates of the alveolar dimensions in 38 healthy elderly never‐smokers (73 ± 6 years, 15 males) and 21 elderly ex‐smokers (70 ± 10 years, 14 males) with (n = 8, 77 ± 6 years) and without emphysema (n = 13, 65 ± 10 years). The ex‐smoker and never‐smoker subgroups were significantly different for FEV1/FVC (P = 0.0001) and DLCO (P = 0.009); while ex‐smokers with emphysema reported significantly diminished FEV1/FVC (P = 0.02) and a trend toward lower DLCO (P = 0.05) than ex‐smokers without emphysema. MRI apparent diffusion coefficients (ADC) and CT measurements of emphysema (relative area–CT density histogram, RA950) were significantly different (P = 0.001 and P = 0.007) for never‐smoker and ex‐smoker subgroups. In never‐smokers, the MRI estimate of mean linear intercept (260 ± 27 μm) was significantly elevated as compared to the results previously reported in younger never‐smokers (210 ± 30 μm), and trended smaller than in the age‐matched ex‐smokers (320 ± 72 μm, P = 0.06) evaluated here. Never‐smokers also reported significantly smaller internal (220 ± 24 μm, P = 0.01) acinar radius but greater alveolar sheath thickness (120 ± 4 μm, P < 0.0001) than ex‐smokers. Never‐smokers were also significantly different than ex‐smokers without emphysema for alveolar sheath thickness but not ADC, while ex‐smokers with emphysema reported significantly different ADC but not alveolar sheath thickness compared to ex‐smokers without CT evidence of emphysema. Differences in alveolar measurements in never‐ and ex‐smokers demonstrate the sensitivity of MRI measurements to the different effects of smoking and aging on acinar morphometry.Keywords
Funding Information
- Canadian Institutes of Health Research (CIHR) New Investigator Award
- CIHR Operating Grant (MOP 106437)
This publication has 48 references indexed in Scilit:
- In Vivo Detection of Acinar Microstructural Changes in Early Emphysema with3He Lung MorphometryRadiology, 2011
- Quantification of lung microstructure with hyperpolarized 3He diffusion MRIJournal of Applied Physiology, 2009
- Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungsMagnetic Resonance Materials in Physics, Biology and Medicine, 2009
- In vivo lung morphometry with hyperpolarized 3He diffusion MRI: Theoretical backgroundJournal of Magnetic Resonance, 2008
- Anatomical distribution of3He apparent diffusion coefficients in severe chronic obstructive pulmonary diseaseJournal of Magnetic Resonance Imaging, 2007
- Assessment of lung development using hyperpolarized helium‐3 diffusion MR imagingJournal of Magnetic Resonance Imaging, 2006
- Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysemaMagnetic Resonance in Medicine, 2006
- Hyperpolarized 3He lung ventilation imaging with B 1-inhomogeneity correction in a single breath-hold scanMagnetic Resonance Materials in Physics, Biology and Medicine, 2004
- The natural history of chronic airflow obstruction.BMJ, 1977
- The Sensitivity Performance of the Human Eye on an Absolute Scale*Journal of the Optical Society of America, 1948