Abstract
Soldering is a common engineering practice that releases airborne particulate matter (PM), contributing to significant long-term respiratory risk. The health impact of this exposure is significant, with up to 22% of soldering workers worldwide being diagnosed with conditions such as occupational asthma, restrictive lung disease, and bronchial obstruction. Studies have reported that soldering can produce PM2.5 concentrations up to 10 times higher than the U.S. Environmental Protection Agency’s (EPA) 24 h exposure limit of 35.0 μg/m3—posing significant respiratory and cognitive health risks under chronic exposure. These hazards remain underappreciated by novice engineers in academic and entry-level industrial environments, where safety practices are often informal or inconsistently applied. Air purification systems offer a mitigation approach; however, performance varies significantly with model and placement, and independent validation is limited. This study uses an indoor air quality monitoring system consisting of six AeroSpec sensors to measure PM2.5–10 concentrations during soldering sessions conducted with and without commercial air purifiers. Tests were conducted with and without a selection of commercial air purifiers, and measurements were recorded under consistent spatial and temporal conditions. Datasets were analyzed to evaluate purifier effectiveness and the influence of placement on pollutant distribution. The findings provide independent validation of air purifier capabilities and offer evidence-based suggestions for minimizing particulate exposure and improving safety in laboratory soldering environments.

This publication has 53 references indexed in Scilit: