AMAlexander V. Mamishev

Alexander V. Mamishev

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alexander V. Mamishev has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative Assessment of Soldering-Induced PM2.5 Exposure Using a Distributed Sensor Network in Instructional Laboratory Settings

    by Ian M. Kinsella, Anna N. Petrbokova, Rongjie Yang, Zheng Liu, Gokul Nathan, Nicklaus Thompson, Alexander V. Mamishev, Sep Makhsous

    Soldering is a common engineering practice that releases airborne particulate matter (PM), contributing to significant long-term respiratory risk. The health impact of this exposure is significant, with up to 22% of soldering workers worldwide being diagnosed with conditions such as occupational asthma, restrictive lung disease, and bronchial obstruction. Studies have reported that soldering can produce PM2.5 concentrations up to 10 times higher than the U.S. Environmental Protection Agency’s (EPA) 24 h exposure limit of 35.0 μg/m3—posing significant respiratory and cognitive health risks under chronic exposure. These hazards remain underappreciated by novice engineers in academic and entry-level industrial environments, where safety practices are often informal or inconsistently applied. Air purification systems offer a mitigation approach; however, performance varies significantly with model and placement, and independent validation is limited. This study uses an indoor air quality monitoring system consisting of six AeroSpec sensors to measure PM2.5–10 concentrations during soldering sessions conducted with and without commercial air purifiers. Tests were conducted with and without a selection of commercial air purifiers, and measurements were recorded under consistent spatial and temporal conditions. Datasets were analyzed to evaluate purifier effectiveness and the influence of placement on pollutant distribution. The findings provide independent validation of air purifier capabilities and offer evidence-based suggestions for minimizing particulate exposure and improving safety in laboratory soldering environments.


  • Open Access

    Methodology for Addressing Infectious Aerosol Persistence in Real-Time Using Sensor Network

    by Sepehr Makhsous, Joelle M. Segovia, Jiayang He, Daniel Chan, Larry Lee, Igor V. Novosselov, Alexander V. Mamishev

    Human exposure to infectious aerosols results in the transmission of diseases such as influenza, tuberculosis, and COVID-19. Most dental procedures generate a significant number of aerosolized particles, increasing transmission risk in dental settings. Since the generation of aerosols in dentistry is unavoidable, many clinics have started using intervention strategies such as area-filtration units and extraoral evacuation equipment, especially under the relatively recent constraints of the pandemic. However, the effectiveness of these devices in dental operatories has not been studied. Therefore, the ability of dental personnel to efficiently position and operate such instruments is also limited. To address these challenges, we utilized a real-time sensor network for assessment of aerosol dynamics during dental restoration and cleaning producers with and without intervention. The strategies tested during the procedures were (i) local area High-Efficiency Particle Air (HEPA) filters and (ii) Extra-Oral Suction Device (EOSD). The study was conducted at the University of Washington School of Dentistry using a network of 13 fixed sensors positioned within the operatory and one wearable sensor worn by the dental operator. The sensor network provides time and space-resolved particulate matter (PM) data. Three-dimensional (3D) visualization informed aerosol persistence in the operatory. It was found that area filters did not improve the overall aerosol concentration in dental offices in a significant way. A decrease in PM concentration by an average of 16% was observed when EOSD equipment was used during the procedures. The combination of real-time sensors and 3D visualization can provide dental personnel and facility managers with actionable feedback to effectively assess aerosol transmission in medical settings and develop evidence-based intervention strategies.


  • Open Access

    Methodology for Addressing Infectious Aerosol Persistence in Real-Time Using Sensor Network

    by Sepehr Makhsous, Joelle M. Segovia, Jiayang He, Daniel Chan, Larry Lee, Igor V Novosselov, Alexander V Mamishev

    Human exposure to infectious aerosols results a transmission of diseases, such as influenza, tuberculosis, and COVID-19. Most dental procedures generate a significant number of aerosolized particles, increasing transmission risk in dental settings. Since the generation of aerosols in dentistry is unavoidable, many clinics started using intervention strategies such as area-filtration units and extraoral evacuation equipment, especially under the relatively recent constraints of the pandemics. However, the effectiveness of these devices in dental operatories has not been studied. Therefore, the dental personnel's ability to position and operate such instruments efficiently is also limited. To address these challenges, we utilized a real-time sensor network for assessment of aerosol dynamics during dental restoration and cleaning producers with and without intervention. The strategies tested during the procedures were (i) local area high-efficiency particle air (HEPA) filters and (ii) extra-oral suction device (EOSD). The study was conducted at the University of Washington School of Dentistry using a network of thirteen fixed sensors positioned within the operatory and one wearable sensor worn by the dental operator. The sensor network provides time and space-resolved particulate matter (PM) data. Three-dimensional (3D) visualization informs aerosol persistence in the operatory. It was found that area filters did not improve the overall aerosol concentration in dental offices significantly. An average of 16% decrease in PM concentration was observed when EOSD equipment was used during the procedures. The combination of real-time sensors and 3D visualization can provide dental personnel and facility mangers with actionable feedback to effectively assess aerosol transmission in medical settings and develop evidence-based intervention strategies.


  • Open Access

    DietSensor: Automatic Dietary Intake Measurement Using Mobile 3D Scanning Sensor for Diabetic Patients

    by Sepehr Makhsous, Mukund Bharadwaj, Benjamin E. Atkinson, Igor V. Novosselov, Alexander V. Mamishev

    Diabetes is a global epidemic that impacts millions of people every year. Enhanced dietary assessment techniques are critical for maintaining a healthy life for a diabetic patient. Moreover, hospitals must monitor their diabetic patients’ food intake to prescribe a certain amount of insulin. Malnutrition significantly increases patient mortality, the duration of the hospital stay, and, ultimately, medical costs. Currently, hospitals are not fully equipped to measure and track a patient’s nutritional intake, and the existing solutions require an extensive user input, which introduces a lot of human errors causing endocrinologists to overlook the measurement. This paper presents DietSensor, a wearable three-dimensional (3D) measurement system, which uses an over the counter 3D camera to assist the hospital personnel with measuring a patient’s nutritional intake. The structured environment of the hospital provides the opportunity to have access to the total nutritional data of any meal prepared in the kitchen as a cloud database. DietSensor uses the 3D scans and correlates them with the hospital kitchen database to calculate the exact consumed nutrition by the patient. The system was tested on twelve volunteers with no prior background or familiarity with the system. The overall calculated nutrition from the DietSensor phone application was compared with the outputs from the 24-h dietary recall (24HR) web application and MyFitnessPal phone application. The average absolute error on the collected data was 73%, 51%, and 33% for the 24HR, MyFitnessPal, and DietSensor systems, respectively.


  • Open Access

    A Novel Mobile Structured Light System in Food 3D Reconstruction and Volume Estimation

    by Sepehr Makhsous, Hashem M. Mohammad, Jeannette M. Schenk, Alexander V. Mamishev, Alan R. Kristal

    Over the past ten years, diabetes has rapidly become more prevalent in all age demographics and especially in children. Improved dietary assessment techniques are necessary for epidemiological studies that investigate the relationship between diet and disease. Current nutritional research is hindered by the low accuracy of traditional dietary intake estimation methods used for portion size assessment. This paper presents the development and validation of a novel instrumentation system for measuring accurate dietary intake for diabetic patients. This instrument uses a mobile Structured Light System (SLS), which measures the food volume and portion size of a patient’s diet in daily living conditions. The SLS allows for the accurate determination of the volume and portion size of a scanned food item. Once the volume of a food item is calculated, the nutritional content of the item can be estimated using existing nutritional databases. The system design includes a volume estimation algorithm and a hardware add-on that consists of a laser module and a diffraction lens. The experimental results demonstrate an improvement of around 40% in the accuracy of the volume or portion size measurement when compared to manual calculation. The limitations and shortcomings of the system are discussed in this manuscript.