Influence of temperature on the response of diamond radiation detectors
- 1 August 2001
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 90 (3) , 1608-1611
Abstract
The response of chemically vapor deposited diamond detectors under alpha particle irradiation was studied as a function of operating temperature in the 20–280 °C range. The detector characteristics were studied for two initial states: (i) the detector being either preirradiated under x-rays at a dose of 8 Gy (pumped state) or (ii) preannealed at 400 °C for 15 min (depumped state). Pumped detectors were found to exhibit a stable response (evaluated by measurement of the charge collection efficiency η) with temperature up to 120 °C, above which a decrease of η was observed. Preannealing at 400 °C was shown to induce, at room temperature, a drastic deterioration of the detector response, when compared to that of pumped devices, whereas above 150 °C a reversed trend was observed. Correlations between the response of the diamond detectors and the presence of traps were determined by comparing the detector response for α particles with the thermally stimulated current (TSC) spectrum. The temperature dependence of the detector response was shown to be related to the presence of a trapping level measured around 260 °C by TSC.Keywords
This publication has 16 references indexed in Scilit:
- Tracking with CVD diamond radiation sensors at high luminosity collidersIEEE Transactions on Nuclear Science, 1999
- Diamond-based semi-transparent beam-position monitor for synchrotron radiation applicationsJournal of Synchrotron Radiation, 1999
- Development of diamond films for particle detector applicationsDiamond and Related Materials, 1998
- Post-growth treatments and contact formation on CVD diamond films for electronic applicationsDiamond and Related Materials, 1998
- High temperature thermally stimulated currents analysis of CVD diamond filmsSolid-State Electronics, 1998
- Optical force microscopy with silicone rubber waveguidesApplied Physics Letters, 1997
- Neutron Detectors Made From Chemically Vapour Deposited SemiconductorsMRS Proceedings, 1997
- Grain size effects in CVD diamond detectorsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1994
- Methods for kinetic analysis of thermally stimulated processesJournal of Materials Science, 1976
- Glow Curves with General Order KineticsJournal of the Electrochemical Society, 1969