Quantitative 90Y image reconstruction in PET
Authors:
- 5 November 2012
- journal article
- Published by Wiley in Medical Physics
- Vol. 39 (11) , 7153-7159
Abstract
Purpose: Positron emission tomography (PET) imaging is increasingly used to confirm localization of90Y microspheres in the treatment of liver cancer. The aim of this work was to evaluate the quantification of 90Y PET data on a current generation time‐of‐flight extended axial field‐of‐view PET/CT camera.Methods: The International Electrotechnical Commission (IEC) body phantom was used to image six spheres of varying diameters containing a high concentration of90Y solution in a lower concentration background. Multiple PET studies were acquired of the phantom over a number of days during decay. The effect of reconstruction parameters in OSEM was evaluated both qualitatively and quantitatively. Expected values of total phantom activity, hot‐sphere, and background concentration were compared to measured values from the reconstructed data as well as misplaced events in a cold insert. The partial volume effect was measured and the effects of time‐of‐flight during reconstruction on hot contrast recovery and background variability were evaluated according to NEMA‐NU2‐2007 protocol, and compared to that for 18F. The method was applied to a patient study following radioembolization to estimate actual implanted radioactivity.Results: Increasing the number of OSEM iterations visually deteriorated image data and resulted in a larger overall difference of hot concentration measures when considering both count high and count poor data. The average difference between measured and true total activity and background concentration was found to be +5% and +5%, respectively. Measured hot‐sphere concentration was linear across all datasets, and while estimated to be within error of expected values, was consistently underestimated by an average of 23%, 12%, and 8%, when using a CT‐derived, 50% threshold‐derived, and 70% threshold‐derived volume of interest, respectively. Partial volume effects were evident in all but the largest sphere, following an expected relationship between object size and recovery coefficient, inferior to that of18F. Time‐of‐flight improved contrast of hot‐spheres but resulted in a deterioration of background variability, following a similar trend to that seen with 18F. The patient data estimated a total implanted activity of 1643 MBq, compared to the intended dose of 1780 MBq, with a difference most likely due to residual and error in the initial dose calibration.Conclusions: Quantitative90Y PET with a state‐of‐the‐art PET/CT scanner with time‐of‐flight and standard corrections for photon interactions demonstrates consistent and acceptable measures of total activity and radionuclide concentration across a range of realistic count statistics. The method is suitable for measuring the radioactivity delivered at the time of 90Y therapy with the potential for absorbed dose calculation.Keywords
This publication has 13 references indexed in Scilit:
- 90Y PET-based dosimetry after selective internal radiotherapy treatmentsNuclear Medicine Communications, 2012
- 90Y-PET for the assessment of microsphere biodistribution after selective internal radiotherapyNuclear Medicine Communications, 2012
- Characterization of Geometric Uncertainties of a Dose Calibrator During Measurement of 90Y ActivityJournal of Nuclear Medicine Technology, 2011
- Yttrium-90-labeled microsphere tracking during liver selective internal radiotherapy by bremsstrahlung pinhole SPECT: feasibility study and evaluation in an abdominal phantomEJNMMI Research, 2011
- Internal Pair Production of 90Y Permits Hepatic Localization of Microspheres Using Routine PET: Proof of ConceptJournal of Nuclear Medicine, 2010
- 4-Step Renal Dosimetry Dependent on Cortex Geometry Applied to 90Y Peptide Receptor Radiotherapy: Evaluation Using a Fillable Kidney Phantom Imaged by 90Y PETJournal of Nuclear Medicine, 2010
- Feasibility of 90Y TOF PET-based dosimetry in liver metastasis therapy using SIR-SpheresEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010
- PET/CT for the assessment and quantification of 90Y biodistribution after selective internal radiotherapy (SIRT) of liver metastasesEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- Yttrium-90 TOF PET scan demonstrates high-resolution biodistribution after liver SIRTEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- A new internal pair production branching ratio of 90Y: The development of a non-destructive assay for 90Y and 90SrApplied Radiation and Isotopes, 2007