Factors affecting corneal hysteresis in normal eyes
Authors:
- 11 June 2008
- journal article
- refractive surgery
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 246 (10) , 1491-1494
Abstract
Background To evaluate factors affecting corneal hysteresis (CH) in normal eyes. Methods We examined 86 normal eyes of 43 healthy volunteers (age, 39.1 ± 14.5 years (mean ± standard deviation); range, 19 to 68 years; gender, 26 men, 60 women; manifest refraction, −2.25 ± 2.89 diopters (D); range, −9.13 to 3.88 D). We quantitatively assessed the value of CH using an Ocular Response Analyzer™ (Reichert Ophthalmic Instruments). We carried out this measurement three times, and the average value was used for statistical analysis. Multiple regression analysis was used to assess the relevant factors of the CH. Results The mean CH was 10.2 ± 1.3 mmHg. Explanatory variables relevant to the CH were, in order of magnitude of influence, the central corneal thickness (CCT) (partial regression coefficient B = 0.022, p < 0.0001), and the intraocular pressure (IOP) (B = -0.119, p = 0.04). No significant correlation was seen with other clinical factors such as age, gender, manifest refraction, or mean keratometric readings. Conclusions Eyes with thinner CCT and eyes with higher IOP are more predisposed to have lower CH. Refractive surgeons should, from a biomechanical viewpoint, take not only CCT but also IOP into consideration before performing keratorefractive surgery.Keywords
This publication has 21 references indexed in Scilit:
- Corneal hysteresis using the Reichert ocular response analyser: findings pre‐ and post‐LASIK and LASEKActa Ophthalmologica, 2008
- Comparison of IOP Measurements Between ORA and GAT in Normal ChineseOptometry and Vision Science, 2007
- Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyesJournal of Cataract & Refractive Surgery, 2007
- Assessment of the Biomechanical Properties of the Cornea with the Ocular Response Analyzer in Normal and Keratoconic EyesInvestigative Ophthalmology & Visual Science, 2007
- Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response AnalyzerInvestigative Ophthalmology & Visual Science, 2006
- Biomechanics and wound healing in the corneaExperimental Eye Research, 2006
- Measuring intraocular pressure-adjustments for corneal thickness and new technologiesCurrent Opinion in Ophthalmology, 2006
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005
- Interferometric technique to measure biomechanical changes in the cornea induced by refractive surgeryJournal of Cataract & Refractive Surgery, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005