Automated MR Image Prescription of the Liver Using Deep Learning: Development, Evaluation, and Prospective Implementation
Authors:
- Ruiqi GengRGRuiqi Geng
- Collin J. BueloCBCollin J. Buelo
- Mahalakshmi SundaresanMSMahalakshmi Sundaresan
- Jitka StarekovaJSJitka Starekova
- Nikolaos PanagiotopoulosNPNikolaos Panagiotopoulos
- Thekla H. OechteringTOThekla H. Oechtering
- Edward M. LawrenceELEdward M. Lawrence
- Scott B. ReederSRScott B. Reeder
- Diego HernandoDHDiego Hernando
Open Access
- 30 December 2022
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (2) , 429-441
Abstract
Background: There is an unmet need for fully automated image prescription of the liver to enable efficient, reproducible MRI.Purpose: To develop and evaluate artificial intelligence (AI)‐based liver image prescription.Study Type: Prospective.Population: A total of 570 female/469 male patients (age: 56 ± 17 years) with 72%/8%/20% assigned randomly for training/validation/testing; two female/four male healthy volunteers (age: 31 ± 6 years).Field Strength/Sequence: 1.5 T, 3.0 T; spin echo, gradient echo, bSSFP.Assessment: A total of 1039 three‐plane localizer acquisitions (26,929 slices) from consecutive clinical liver MRI examinations were retrieved retrospectively and annotated by six radiologists. The localizer images and manual annotations were used to train an object‐detection convolutional neural network (YOLOv3) to detect multiple object classes (liver, torso, and arms) across localizer image orientations and to output corresponding 2D bounding boxes. Whole‐liver image prescription in standard orientations was obtained based on these bounding boxes. 2D detection performance was evaluated on test datasets by calculating intersection over union (IoU) between manual and automated labeling. 3D prescription accuracy was calculated by measuring the boundary mismatch in each dimension and percentage of manual volume covered by AI prescription. The automated prescription was implemented on a 3 T MR system and evaluated prospectively on healthy volunteers.Statistical Tests: Paired t‐tests (threshold = 0.05) were conducted to evaluate significance of performance difference between trained networks.Results: In 208 testing datasets, the proposed method with full network had excellent agreement with manual annotations, with median IoU > 0.91 (interquartile range < 0.09) across all seven classes. The automated 3D prescription was accurate, with shifts <2.3 cm in superior/inferior dimension for 3D axial prescription for 99.5% of test datasets, comparable to radiologists' interreader reproducibility. The full network had significantly superior performance than the tiny network for 3D axial prescription in patients. Automated prescription performed well across single‐shot fast spin‐echo, gradient‐echo, and balanced steady‐state free‐precession sequences in the prospective study.Data Conclusion: AI‐based automated liver image prescription demonstrated promising performance across the patients, pathologies, and field strengths studied.Evidence Level: 4.Technical Efficacy: Stage 1.Keywords
Funding Information
- Deutsche Forschungsgemeinschaft (OE 746/1‐1)
- National Institutes of Health (R01‐EB031886)
- GE Healthcare
- Bracco Diagnostics
- Wisconsin Alumni Research Foundation
This publication has 28 references indexed in Scilit:
- SSD: Single Shot MultiBox Detector2016
- Faster R-CNN: Towards Real-Time Object Detection with Region Proposal NetworksIEEE Transactions on Pattern Analysis and Machine Intelligence, 2016
- Body MR Imaging: Artifacts, k-Space, and SolutionsRadioGraphics, 2015
- A novel platform for comprehensive CMR examination in a clinically feasible scan timeJournal of Cardiovascular Magnetic Resonance, 2014
- Automated Scan Prescription for MR Imaging of Deformed and Normal LiversMagnetic Resonance in Medical Sciences, 2013
- Impacting Key Performance Indicators in an Academic MR Imaging Department Through Process ImprovementJournal of the American College of Radiology, 2012
- Process analysis to reduce MRI access time at a German University HospitalInternational Journal for Quality in Health Care, 2011
- Evaluation of MRI Acquisition Workflow With Lean Six Sigma Method: Case Study of Liver and Knee ExaminationsAmerican Journal of Roentgenology, 2010
- The Pascal Visual Object Classes (VOC) ChallengeInternational Journal of Computer Vision, 2009
- Clinical evaluation of automated scan prescription of knee MR imagesJournal of Magnetic Resonance Imaging, 2008