Thekla Helene Oechtering
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thekla Helene Oechtering has a total of 185 co-authors. Here are the top co-authors by number of shared publications:
- Alex Frydrychowicz
Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Germany
8 shared publications Jörg Barkhausen
Department of Radiology and Nuclear Medicine, Universität zu Lübeck, Lübeck, Germany
7 shared publications- Malte Maria Sieren
Institute of Radiology and Nuclear Medicine University of Luebeck Lübeck Germany
6 shared publications - Scott Brian Reeder
Department of Radiology University of Wisconsin–Madison Madison Wisconsin USA
6 shared publications - Jörg Barkhausen
Institute of Radiology and Nuclear Medicine University of Luebeck Lübeck Germany
5 shared publications - Alejandro Roldán-Alzate
Department of Radiology University of Wisconsin‐Madison Madison Wisconsin USA
4 shared publications
Latest Publications
- Open Access
- 23 June 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (4) , 898-905
Postprandial Changes in Thoracic Aortic Flow Detected by 4D Flow MRI May Influence Study Results
Background: While there is a growing body of data using 4D flow MRI to distinguish between normal and abnormal blood flow values in the thoracic aorta, the extent of physiological variation or lack thereof is potentially undervalued. Physiological processes such as postprandial changes to hemodynamics might influence data, normal values, follow‐up studies, and data compared between study sites. Purpose: To determine the influence of food intake on flow parameters in the thoracic aorta of young healthy volunteers by 4D flow MRI. Study Type: Prospective. Subjects: 20 young healthy (10 male, 10 female) volunteers were recruited for this study. Field Strength/Sequence: 3T/4D flow MRI (three‐dimensional time‐resolved phase‐contrast spoiled gradient‐echo with three‐directional velocity‐encoding). Technical parameters were chosen according to consensus recommendations, including the use of a respiratory navigator, included a 10 mm respiratory navigator window, retrospective ECG gating, VENC 180–200 cm/s, voxel size 2.5 × 2.5 × 2.0–2.5 mm 3 , temporal resolution 41 ms and parallel imaging with acceleration factor of 4. Acquisition time was 10.3 ± 2.4 min. Assessment: Volunteers' thoracic aorta was imaged after fasting (food ≥ 6 h, liquid ≥ 2 h) and after a meal challenge to detect changes in aortic hemodynamics (stroke volume, flow, and velocity). Statistical Tests: Statistics included calculation of relative difference (RD), two‐tailed paired t ‐test, and Pearson coefficient. p < 0.05 was considered significant. Results: 4D flow MRI detected statistically significant postprandial increases in stroke volume (pre: 93 ± 18 mL; post: 99 ± 24 mL, RD = 5 ± 13%), peak flow (pre: 433 ± 95 mL/s; post: 467 ± 95 mL/s, RD = 9 ± 14%), peak average velocity (pre: 73 ± 18 cm/s; post: 78 ± 16 cm/s, RD = 8 ± 11%), and maximum velocity (pre: 118 ± 24 cm/s; post: 131 ± 23 cm/s, RD = 11 ± 11%); values given for ascending aorta. 74% of individuals presented with postprandial increase in peak flow and velocities throughout the thoracic aorta. Data Conclusion: Food intake triggers a small but significant increase in stroke volume, flow, and velocity in the aorta in young healthy individuals. Depending on the study question and potential longitudinal comparisons, one may consider introducing a fasting period prior to 4D flow MRI to avoid measurements at peak postprandial hyperemia. Evidence Level: 2. Technical Efficacy: Stage 3, diagnostic thinking.
- 23 June 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 64 (4) , 898-905
Open AccessPostprandial Changes in Thoracic Aortic Flow Detected by 4D Flow MRI May Influence Study Results
Background: While there is a growing body of data using 4D flow MRI to distinguish between normal and abnormal blood flow values in the thoracic aorta, the extent of physiological variation or lack thereof is potentially undervalued. Physiological processes such as postprandial changes to hemodynamics might influence data, normal values, follow‐up studies, and data compared between study sites. Purpose: To determine the influence of food intake on flow parameters in the thoracic aorta of young healthy volunteers by 4D flow MRI. Study Type: Prospective. Subjects: 20 young healthy (10 male, 10 female) volunteers were recruited for this study. Field Strength/Sequence: 3T/4D flow MRI (three‐dimensional time‐resolved phase‐contrast spoiled gradient‐echo with three‐directional velocity‐encoding). Technical parameters were chosen according to consensus recommendations, including the use of a respiratory navigator, included a 10 mm respiratory navigator window, retrospective ECG gating, VENC 180–200 cm/s, voxel size 2.5 × 2.5 × 2.0–2.5 mm 3 , temporal resolution 41 ms and parallel imaging with acceleration factor of 4. Acquisition time was 10.3 ± 2.4 min. Assessment: Volunteers' thoracic aorta was imaged after fasting (food ≥ 6 h, liquid ≥ 2 h) and after a meal challenge to detect changes in aortic hemodynamics (stroke volume, flow, and velocity). Statistical Tests: Statistics included calculation of relative difference (RD), two‐tailed paired t ‐test, and Pearson coefficient. p < 0.05 was considered significant. Results: 4D flow MRI detected statistically significant postprandial increases in stroke volume (pre: 93 ± 18 mL; post: 99 ± 24 mL, RD = 5 ± 13%), peak flow (pre: 433 ± 95 mL/s; post: 467 ± 95 mL/s, RD = 9 ± 14%), peak average velocity (pre: 73 ± 18 cm/s; post: 78 ± 16 cm/s, RD = 8 ± 11%), and maximum velocity (pre: 118 ± 24 cm/s; post: 131 ± 23 cm/s, RD = 11 ± 11%); values given for ascending aorta. 74% of individuals presented with postprandial increase in peak flow and velocities throughout the thoracic aorta. Data Conclusion: Food intake triggers a small but significant increase in stroke volume, flow, and velocity in the aorta in young healthy individuals. Depending on the study question and potential longitudinal comparisons, one may consider introducing a fasting period prior to 4D flow MRI to avoid measurements at peak postprandial hyperemia. Evidence Level: 2. Technical Efficacy: Stage 3, diagnostic thinking.
- 2 February 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (3) , 357-364
Hemodynamic Changes After Portal Vein Embolization Predict Future Liver Remnant Growth: A 4D Flow MRI Feasibility Study in Pigs
Objectives: Early prediction of remnant liver growth after portal vein embolization (PVE) would enable earlier surgery in patients with resectable liver malignancy, decreasing the risk of tumor progression. This study aims to demonstrate the feasibility of 4D flow MRI to detect changes in portal blood flow before and after PVE and determine whether 4D flow MRI can predict hypertrophy of nonembolized liver lobes (future liver remnant) in a porcine model. Methods: Thirteen juvenile pigs were included in this prospective study. In 11 pigs, 2 of the 4 portal vein branches were selectively embolized using polyvinyl alcohol particles. Two pigs served as controls. All animals were imaged before, 1 hour, and 1 and 2 weeks after PVE using 4D flow and T1-weighted 3D spoiled gradient-echo MRI. Flow measurements were correlated with liver volumetry measurements. The predictive value of flow changes immediately after PVE for future liver remnant hypertrophy at 2 weeks was estimated using linear mixed-effect model analysis. Results: Twelve pigs completed the study. One treatment pig died from complications of anesthesia. Immediately after PVE, relative flow in the 2 embolized portal vein branches decreased from 17.0±2.1% to 3.4±2.1% of total portal flow, respectively. Relative flow increased from 16.6±3.8% to 32.6±3.8% in the remaining 2 nonembolized portal vein branches supplying the future liver remnant. Each 1% increase in relative blood flow directly after the procedure predicted a 4.8±0.7 cm 3 (estimate±SE) increase in volume of the future liver remnant at 2 weeks ( P 3 ( P =0.003). Conclusion: 4D flow MRI successfully quantified portal blood flow before and after portal vein embolization in a porcine model. Notably, immediate postembolization changes in portal flow were predictive of lobar volume changes observed at 2 weeks. This porcine model thus provides a valuable platform for investigating the relationship between portal hemodynamics and hypertrophy of the future liver remnant. Furthermore, it will enable systematic evaluation of various embolization agents and techniques, supporting the refinement of interventional strategies in hepatic regenerative research.
- 2 February 2026
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 50 (3) , 357-364
Hemodynamic Changes After Portal Vein Embolization Predict Future Liver Remnant Growth: A 4D Flow MRI Feasibility Study in Pigs
Objectives: Early prediction of remnant liver growth after portal vein embolization (PVE) would enable earlier surgery in patients with resectable liver malignancy, decreasing the risk of tumor progression. This study aims to demonstrate the feasibility of 4D flow MRI to detect changes in portal blood flow before and after PVE and determine whether 4D flow MRI can predict hypertrophy of nonembolized liver lobes (future liver remnant) in a porcine model. Methods: Thirteen juvenile pigs were included in this prospective study. In 11 pigs, 2 of the 4 portal vein branches were selectively embolized using polyvinyl alcohol particles. Two pigs served as controls. All animals were imaged before, 1 hour, and 1 and 2 weeks after PVE using 4D flow and T1-weighted 3D spoiled gradient-echo MRI. Flow measurements were correlated with liver volumetry measurements. The predictive value of flow changes immediately after PVE for future liver remnant hypertrophy at 2 weeks was estimated using linear mixed-effect model analysis. Results: Twelve pigs completed the study. One treatment pig died from complications of anesthesia. Immediately after PVE, relative flow in the 2 embolized portal vein branches decreased from 17.0±2.1% to 3.4±2.1% of total portal flow, respectively. Relative flow increased from 16.6±3.8% to 32.6±3.8% in the remaining 2 nonembolized portal vein branches supplying the future liver remnant. Each 1% increase in relative blood flow directly after the procedure predicted a 4.8±0.7 cm 3 (estimate±SE) increase in volume of the future liver remnant at 2 weeks ( P 3 ( P =0.003). Conclusion: 4D flow MRI successfully quantified portal blood flow before and after portal vein embolization in a porcine model. Notably, immediate postembolization changes in portal flow were predictive of lobar volume changes observed at 2 weeks. This porcine model thus provides a valuable platform for investigating the relationship between portal hemodynamics and hypertrophy of the future liver remnant. Furthermore, it will enable systematic evaluation of various embolization agents and techniques, supporting the refinement of interventional strategies in hepatic regenerative research.
- 25 March 2025
- Published by Wolters Kluwer Health in Hepatology
- Vol. 83 (1) , 127-141
Proton density fat fraction for diagnosis of metabolic dysfunction–associated steatotic liver disease
Background and Aims: Prior work has shown that MRI-derived proton density fat fraction (PDFF) can diagnose metabolic dysfunction-associated steatotic liver disease (MASLD) noninvasively, but there is a paucity of data on the performance of PDFF to classify more advanced forms of the MASLD spectrum. The purpose of this study was to assess the diagnostic performance of PDFF for the diagnoses of MASLD, metabolic dysfunction-associated steatohepatitis (MASH), and fibrotic MASH in adults with obesity undergoing bariatric surgery, using contemporaneous intraoperative liver biopsy as a reference. Approach and Results: PDFF was evaluated alone and with other potential classifiers (imaging, serum and anthropometric), using Bayesian Information Criterion-based stepwise logistic regression models. Areas under the receiver operating characteristic (ROC) curves (AUC) were computed for all models and single classifiers. Cross-validated sensitivity and specificity were calculated at Youden-based PDFF classification thresholds. Data analysis from 140 patients demonstrated that PDFF was the most accurate single classifier, with high AUC for MASLD (0.95), MASH (0.85), and fibrotic MASH (0.82) (all p <0.001). Multivariable models, including PDFF, outperformed those without PDFF. The Youden-based threshold for PDFF was 4.4% for MASLD (sensitivity: 87%, specificity: 86%), 6.9% for MASH (sensitivity: 77%, specificity: 66%), and 13.5% for fibrotic MASH (sensitivity: 67%, specificity: 85%). Conclusions: PDFF was the most accurate single classifier for diagnosing MASLD, MASH, and fibrotic MASH. The most accurate multivariable classification models for MASLD, MASH, and fibrotic MASH included PDFF, demonstrating the central importance of PDFF for noninvasive assessment of the MASLD spectrum.
- 25 March 2025
- Published by Wolters Kluwer Health in Hepatology
- Vol. 83 (1) , 127-141
Proton density fat fraction for diagnosis of metabolic dysfunction–associated steatotic liver disease
Background and Aims: Prior work has shown that MRI-derived proton density fat fraction (PDFF) can diagnose metabolic dysfunction-associated steatotic liver disease (MASLD) noninvasively, but there is a paucity of data on the performance of PDFF to classify more advanced forms of the MASLD spectrum. The purpose of this study was to assess the diagnostic performance of PDFF for the diagnoses of MASLD, metabolic dysfunction-associated steatohepatitis (MASH), and fibrotic MASH in adults with obesity undergoing bariatric surgery, using contemporaneous intraoperative liver biopsy as a reference. Approach and Results: PDFF was evaluated alone and with other potential classifiers (imaging, serum and anthropometric), using Bayesian Information Criterion-based stepwise logistic regression models. Areas under the receiver operating characteristic (ROC) curves (AUC) were computed for all models and single classifiers. Cross-validated sensitivity and specificity were calculated at Youden-based PDFF classification thresholds. Data analysis from 140 patients demonstrated that PDFF was the most accurate single classifier, with high AUC for MASLD (0.95), MASH (0.85), and fibrotic MASH (0.82) (all p <0.001). Multivariable models, including PDFF, outperformed those without PDFF. The Youden-based threshold for PDFF was 4.4% for MASLD (sensitivity: 87%, specificity: 86%), 6.9% for MASH (sensitivity: 77%, specificity: 66%), and 13.5% for fibrotic MASH (sensitivity: 67%, specificity: 85%). Conclusions: PDFF was the most accurate single classifier for diagnosing MASLD, MASH, and fibrotic MASH. The most accurate multivariable classification models for MASLD, MASH, and fibrotic MASH included PDFF, demonstrating the central importance of PDFF for noninvasive assessment of the MASLD spectrum.
- Open Access
- 1 January 2025
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 24 (4)
Artifact-robust Deep Learning-based Segmentation of 3D Phase-contrast MR Angiography: A Novel Data Augmentation Approach
This study presents a novel data augmentation approach to improve deep learning (DL)-based segmentation for 3D phase-contrast magnetic resonance angiography (PC-MRA) images affected by pulsation artifacts. Augmentation was achieved by simulating pulsation artifacts through the addition of periodic errors in k-space magnitude. The approach was evaluated on PC-MRA datasets from 16 volunteers, comparing DL segmentation with and without pulsation artifact augmentation to a level-set algorithm. Results demonstrate that DL methods significantly outperform the level-set approach and that pulsation artifact augmentation further improves segmentation accuracy, especially for images with lower velocity encoding. Quantitative analysis using Dice-Sørensen coefficient, Intersection over Union, and Average Symmetric Surface Distance metrics confirms the effectiveness of the proposed method. This technique shows promise for enhancing vascular segmentation in various anatomical regions affected by pulsation artifacts, potentially improving clinical applications of PC-MRA.
- 1 January 2025
- Published by Japanese Society for Magnetic Resonance in Medicine in Magnetic Resonance in Medical Sciences
- Vol. 24 (4)
Open AccessArtifact-robust Deep Learning-based Segmentation of 3D Phase-contrast MR Angiography: A Novel Data Augmentation Approach
This study presents a novel data augmentation approach to improve deep learning (DL)-based segmentation for 3D phase-contrast magnetic resonance angiography (PC-MRA) images affected by pulsation artifacts. Augmentation was achieved by simulating pulsation artifacts through the addition of periodic errors in k-space magnitude. The approach was evaluated on PC-MRA datasets from 16 volunteers, comparing DL segmentation with and without pulsation artifact augmentation to a level-set algorithm. Results demonstrate that DL methods significantly outperform the level-set approach and that pulsation artifact augmentation further improves segmentation accuracy, especially for images with lower velocity encoding. Quantitative analysis using Dice-Sørensen coefficient, Intersection over Union, and Average Symmetric Surface Distance metrics confirms the effectiveness of the proposed method. This technique shows promise for enhancing vascular segmentation in various anatomical regions affected by pulsation artifacts, potentially improving clinical applications of PC-MRA.
- 1 September 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 308 (3) , e232190
Four-dimensional Flow MRI Helps Predict Future Liver Remnant Hypertrophy after Transhepatic Portal Vein Embolization
- 1 September 2023
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 308 (3) , e232190
Four-dimensional Flow MRI Helps Predict Future Liver Remnant Hypertrophy after Transhepatic Portal Vein Embolization
- Open Access
- 10 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 444-457
Fat mitigation strategies to improve image quality of radial 4D flow MRI in obese subjects
Purpose: This study addresses the challenges in obtaining abdominal 4D flow MRI of obese patients. We aimed to evaluate spectral saturation and inner volume excitation as methods to mitigating artifacts originating from adipose signals, with the goal of enhancing image quality and improving quantification.Methods: Radial 4D flow MRI acquisitions with fat mitigation (inner volume excitation [IVE] and intermittent fat saturation [FS]) were compared to a standard slab selective excitation (SSE) in a test–retest study of 15 obese participants. IVE selectively excited a cylindrical region of interest, avoiding contamination from peripheral adipose tissue, while FS globally suppressed fat based on spectral selection. Acquisitions were evaluated qualitatively based on expert ratings and quantitatively based on conservation of mass, test–retest repeatability, and a divergence free quality metric. Errors were evaluated statistically using the absolute and relative errors, regression, and Bland–Altman analysis.Results: IVE demonstrated superior performance quantitatively in the conservation of mass analysis in the portal vein, with higher correlation and lower bias in regression analysis. IVE also produced flow fields with the lowest divergence error and was rated best in overall image quality, delineating small vessels, and producing the least streaking artifacts. Evaluation results did not differ significantly between FS and SSE. Test–retest reproducibility was similarly high for all sequences, with data suggesting biological variations dominate the technical variability.Conclusion: IVE improved hemodynamic assessment of radial 4D flow MRI in the abdomen of obese participants while FS did not lead to significant improvements in image quality or flow metrics.
- 10 April 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 90 (2) , 444-457
Open AccessFat mitigation strategies to improve image quality of radial 4D flow MRI in obese subjects
Purpose: This study addresses the challenges in obtaining abdominal 4D flow MRI of obese patients. We aimed to evaluate spectral saturation and inner volume excitation as methods to mitigating artifacts originating from adipose signals, with the goal of enhancing image quality and improving quantification.Methods: Radial 4D flow MRI acquisitions with fat mitigation (inner volume excitation [IVE] and intermittent fat saturation [FS]) were compared to a standard slab selective excitation (SSE) in a test–retest study of 15 obese participants. IVE selectively excited a cylindrical region of interest, avoiding contamination from peripheral adipose tissue, while FS globally suppressed fat based on spectral selection. Acquisitions were evaluated qualitatively based on expert ratings and quantitatively based on conservation of mass, test–retest repeatability, and a divergence free quality metric. Errors were evaluated statistically using the absolute and relative errors, regression, and Bland–Altman analysis.Results: IVE demonstrated superior performance quantitatively in the conservation of mass analysis in the portal vein, with higher correlation and lower bias in regression analysis. IVE also produced flow fields with the lowest divergence error and was rated best in overall image quality, delineating small vessels, and producing the least streaking artifacts. Evaluation results did not differ significantly between FS and SSE. Test–retest reproducibility was similarly high for all sequences, with data suggesting biological variations dominate the technical variability.Conclusion: IVE improved hemodynamic assessment of radial 4D flow MRI in the abdomen of obese participants while FS did not lead to significant improvements in image quality or flow metrics.
- 4 April 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (6) , 2049-2059
Reference values for 4D flow magnetic resonance imaging of the portal venous system
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18–74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and − 1.4 ± 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. Graphical abstract
- 4 April 2023
- Published by Springer Nature in Abdominal Radiology
- Vol. 48 (6) , 2049-2059
Reference values for 4D flow magnetic resonance imaging of the portal venous system
Purpose The purpose of this work was to establish normal reference values for 4D flow MRI-derived flow, velocity, and vessel diameters, and to define characteristic flow patterns in the portal venous system of healthy adult subjects. Methods For this retrospective study, we screened all available 4D flow MRI exams of the upper abdomen in healthy adults acquired at our institution between 2012 and 2022 at either 1.5 T or 3.0 T MRI after ≥ 5 h fasting. Flow, velocity, and effective diameter were quantified in the 8 planes in the portal venous system (splenic vein, superior mesenteric vein, main, right, and left portal veins). Vessel delineation was manually adjusted over time. Reference ranges for were defined as the mean ± 2 standard deviations. Three readers noted helical and vortical flow on time-resolved pathline visualizations. Conservation of mass flow analysis was performed for quality assurance. Results We included 44 healthy subjects (26 female, 18–74 years) in the analysis. We report reference values for mean and peak flow, mean velocity, and vessel diameter in the healthy portal vein using 4D flow MRI. Normal flow patterns in the portal vein included faint helical (66%) or linear flow (34%). Conservation of mass analysis demonstrated a relative error of 1.1 ± 4.6% standard deviation (SD) at the splenomesenteric confluence and − 1.4 ± 4.1% SD at the portal bifurcation. Conclusion We have reported normal hemodynamic values that are necessary baseline data for emerging clinical applications of 4D flow MRI in the portal venous system. Results are consistent with previously published values from smaller cohorts. Graphical abstract
- Open Access
- 28 March 2023
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 25 (1) , 22-18
Repeatability and reproducibility of various 4D Flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study
- 28 March 2023
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 25 (1) , 22-18
Open AccessRepeatability and reproducibility of various 4D Flow MRI postprocessing software programs in a multi-software and multi-vendor cross-over comparison study
- Open Access
- 10 March 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (8) , 5664-5674
Work expectations, their fulfillment, and exhaustion among radiologists of all career levels: what can be learned from the example of Germany
Objectives: To evaluate work expectations of radiologists at different career levels, their fulfillment, prevalence of exhaustion, and exhaustion-associated factors. Methods: A standardized digital questionnaire was distributed internationally to radiologists of all career levels in the hospital and in ambulatory care via radiological societies and sent manually to 4500 radiologists of the largest German hospitals between December 2020 and April 2021. Statistics were based on age- and gender-adjusted regression analyses of respondents working in Germany (510 out of 594 total respondents). Results: The most frequent expectations were “joy at work” (97%) and a “good working atmosphere” (97%), which were considered fulfilled by at least 78%. The expectation of a “structured residency within the regular time interval” (79%) was more frequently judged fulfilled by senior physicians (83%, odds ratio (OR) 4.31 [95% confidence interval (95% CI) 1.95–9.52]), chief physicians (85%, 6.81 [95% CI 1.91–24.29]), and radiologists outside the hospital (88%, 7.59 [95% CI 2.40–24.03]) than by residents (68%). Exhaustion was most common among residents (physical exhaustion: 38%; emotional exhaustion: 36%), in-hospital specialists (29%; 38%), and senior physicians (30%; 29%). In contrast to paid extra hours, unpaid extra hours were associated with physical exhaustion (5–10 extra hours: OR 2.54 [95% CI 1.54–4.19]). Fewer opportunities to shape the work environment were related to a higher probability of physical (2.03 [95% CI 1.32–3.13]) and emotional (2.15 [95% CI 1.39–3.33]) exhaustion. Conclusions: While most radiologists enjoy their work, residents wish for more training structure. Ensuring payment of extra hours and employee empowerment may help preventing burnout in high-risk groups. Key Points: • Most important work expectations of radiologists who work in Germany are “joy at work,” a “good working atmosphere,” “support for further qualification,” and a “structured residency within the regular time interval,” with the latter containing potential for improvement according to residents. • Physical and emotional exhaustion are common at all career levels except for chief physicians and for radiologists who work outside the hospital in ambulatory care. • Exhaustion as a major burnout criterion is associated with unpaid extra hours and reduced opportunities to shape the work environment.
- 10 March 2023
- Published by Springer Nature in European Radiology
- Vol. 33 (8) , 5664-5674
Open AccessWork expectations, their fulfillment, and exhaustion among radiologists of all career levels: what can be learned from the example of Germany
Objectives: To evaluate work expectations of radiologists at different career levels, their fulfillment, prevalence of exhaustion, and exhaustion-associated factors. Methods: A standardized digital questionnaire was distributed internationally to radiologists of all career levels in the hospital and in ambulatory care via radiological societies and sent manually to 4500 radiologists of the largest German hospitals between December 2020 and April 2021. Statistics were based on age- and gender-adjusted regression analyses of respondents working in Germany (510 out of 594 total respondents). Results: The most frequent expectations were “joy at work” (97%) and a “good working atmosphere” (97%), which were considered fulfilled by at least 78%. The expectation of a “structured residency within the regular time interval” (79%) was more frequently judged fulfilled by senior physicians (83%, odds ratio (OR) 4.31 [95% confidence interval (95% CI) 1.95–9.52]), chief physicians (85%, 6.81 [95% CI 1.91–24.29]), and radiologists outside the hospital (88%, 7.59 [95% CI 2.40–24.03]) than by residents (68%). Exhaustion was most common among residents (physical exhaustion: 38%; emotional exhaustion: 36%), in-hospital specialists (29%; 38%), and senior physicians (30%; 29%). In contrast to paid extra hours, unpaid extra hours were associated with physical exhaustion (5–10 extra hours: OR 2.54 [95% CI 1.54–4.19]). Fewer opportunities to shape the work environment were related to a higher probability of physical (2.03 [95% CI 1.32–3.13]) and emotional (2.15 [95% CI 1.39–3.33]) exhaustion. Conclusions: While most radiologists enjoy their work, residents wish for more training structure. Ensuring payment of extra hours and employee empowerment may help preventing burnout in high-risk groups. Key Points: • Most important work expectations of radiologists who work in Germany are “joy at work,” a “good working atmosphere,” “support for further qualification,” and a “structured residency within the regular time interval,” with the latter containing potential for improvement according to residents. • Physical and emotional exhaustion are common at all career levels except for chief physicians and for radiologists who work outside the hospital in ambulatory care. • Exhaustion as a major burnout criterion is associated with unpaid extra hours and reduced opportunities to shape the work environment.
- Open Access
- 30 December 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (2) , 429-441
Automated MR Image Prescription of the Liver Using Deep Learning: Development, Evaluation, and Prospective Implementation
Background: There is an unmet need for fully automated image prescription of the liver to enable efficient, reproducible MRI.Purpose: To develop and evaluate artificial intelligence (AI)‐based liver image prescription.Study Type: Prospective.Population: A total of 570 female/469 male patients (age: 56 ± 17 years) with 72%/8%/20% assigned randomly for training/validation/testing; two female/four male healthy volunteers (age: 31 ± 6 years).Field Strength/Sequence: 1.5 T, 3.0 T; spin echo, gradient echo, bSSFP.Assessment: A total of 1039 three‐plane localizer acquisitions (26,929 slices) from consecutive clinical liver MRI examinations were retrieved retrospectively and annotated by six radiologists. The localizer images and manual annotations were used to train an object‐detection convolutional neural network (YOLOv3) to detect multiple object classes (liver, torso, and arms) across localizer image orientations and to output corresponding 2D bounding boxes. Whole‐liver image prescription in standard orientations was obtained based on these bounding boxes. 2D detection performance was evaluated on test datasets by calculating intersection over union (IoU) between manual and automated labeling. 3D prescription accuracy was calculated by measuring the boundary mismatch in each dimension and percentage of manual volume covered by AI prescription. The automated prescription was implemented on a 3 T MR system and evaluated prospectively on healthy volunteers.Statistical Tests: Paired t‐tests (threshold = 0.05) were conducted to evaluate significance of performance difference between trained networks.Results: In 208 testing datasets, the proposed method with full network had excellent agreement with manual annotations, with median IoU > 0.91 (interquartile range < 0.09) across all seven classes. The automated 3D prescription was accurate, with shifts <2.3 cm in superior/inferior dimension for 3D axial prescription for 99.5% of test datasets, comparable to radiologists' interreader reproducibility. The full network had significantly superior performance than the tiny network for 3D axial prescription in patients. Automated prescription performed well across single‐shot fast spin‐echo, gradient‐echo, and balanced steady‐state free‐precession sequences in the prospective study.Data Conclusion: AI‐based automated liver image prescription demonstrated promising performance across the patients, pathologies, and field strengths studied.Evidence Level: 4.Technical Efficacy: Stage 1.
- 30 December 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 58 (2) , 429-441
Open AccessAutomated MR Image Prescription of the Liver Using Deep Learning: Development, Evaluation, and Prospective Implementation
Background: There is an unmet need for fully automated image prescription of the liver to enable efficient, reproducible MRI.Purpose: To develop and evaluate artificial intelligence (AI)‐based liver image prescription.Study Type: Prospective.Population: A total of 570 female/469 male patients (age: 56 ± 17 years) with 72%/8%/20% assigned randomly for training/validation/testing; two female/four male healthy volunteers (age: 31 ± 6 years).Field Strength/Sequence: 1.5 T, 3.0 T; spin echo, gradient echo, bSSFP.Assessment: A total of 1039 three‐plane localizer acquisitions (26,929 slices) from consecutive clinical liver MRI examinations were retrieved retrospectively and annotated by six radiologists. The localizer images and manual annotations were used to train an object‐detection convolutional neural network (YOLOv3) to detect multiple object classes (liver, torso, and arms) across localizer image orientations and to output corresponding 2D bounding boxes. Whole‐liver image prescription in standard orientations was obtained based on these bounding boxes. 2D detection performance was evaluated on test datasets by calculating intersection over union (IoU) between manual and automated labeling. 3D prescription accuracy was calculated by measuring the boundary mismatch in each dimension and percentage of manual volume covered by AI prescription. The automated prescription was implemented on a 3 T MR system and evaluated prospectively on healthy volunteers.Statistical Tests: Paired t‐tests (threshold = 0.05) were conducted to evaluate significance of performance difference between trained networks.Results: In 208 testing datasets, the proposed method with full network had excellent agreement with manual annotations, with median IoU > 0.91 (interquartile range < 0.09) across all seven classes. The automated 3D prescription was accurate, with shifts <2.3 cm in superior/inferior dimension for 3D axial prescription for 99.5% of test datasets, comparable to radiologists' interreader reproducibility. The full network had significantly superior performance than the tiny network for 3D axial prescription in patients. Automated prescription performed well across single‐shot fast spin‐echo, gradient‐echo, and balanced steady‐state free‐precession sequences in the prospective study.Data Conclusion: AI‐based automated liver image prescription demonstrated promising performance across the patients, pathologies, and field strengths studied.Evidence Level: 4.Technical Efficacy: Stage 1.