The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period
Open Access
- 31 July 2015
- journal article
- research article
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 9 (1) , 243-249
Abstract
Purpose: When soft tissue flaps are reflected for implant placement, the blood supply from the periosteum to the bone is disrupted. The aim of this study was to compare the effects of the flapless (FL) and full-thickness flap (FT) techniques on implant stability.Methods:Nine patients received 22 implants. The implants were placed using the FL technique on the contralateral side of the jaw; the FT technique was used as the control technique. Resonance frequency analysis (RFA) was performed at the time of implant placement and at 6 and 12 weeks after implant placement. RFA values were compared between the FL and FT groups and between time intervals in the same group.Results:The median (interquartile range [IQR]) RFA values at the time of implant placement were 75.00 (15.00) for the FL technique and 75.00 (9.00) for the FT technique. At 6 weeks, the median (IQR) values were 79 (3.30) for the FL technique and 80 (12.70) for the FT technique. At 12 weeks, the median (IQR) values were 82.3 (3.30) for the FL technique and 82.6 (8.00) for the FT technique. There were no significant differences between the 2 techniques at the time of implant placement, after 6 weeks or after 12 weeks, with p values of 0.994, 0.789, and 0.959, respectively. There were significant differences between the RFA values at the time of implant placement and after 6 weeks for the FL technique (p=0.028) but not for the FT technique (p=0.091). There were also significant differences between the RFA values at 6 weeks and the RFA values at 12 weeks for the FL technique (p=0.007) and for the FT technique (p=0.003).Conclusion:Periosteum preservation during the FL procedure will speed up bone remodeling and result in early secondary implant stability as well as early loading.Keywords
This publication has 27 references indexed in Scilit:
- Effect of Surgical Techniques on Primary Implant Stability and Peri-Implant BoneJournal of Oral and Maxillofacial Surgery, 2007
- Multivariate study of factors influencing primary dental implant stabilityClinical Oral Implants Research, 2007
- Flapless implant surgery: an experimental studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2007
- Histologic Evaluation of Implants Following Flapless and Flapped Surgery: A Study in CaninesJournal of Periodontology, 2006
- The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approachJournal of Biomechanics, 2006
- Influence of cortical bone thickness and implant length on implant stability at the time of surgery—clinical, prospective, biomechanical, and imaging studyBone, 2005
- Resonance frequency analysis and damping capacity assessmentClinical Oral Implants Research, 2005
- Resonance Frequency Analysis of One‐ Stage Dental Implant Stability During the Osseointegration PeriodJournal of Periodontology, 2005
- Resonance frequency analysis of implants subjected to immediate or early functional occlusal loadingClinical Oral Implants Research, 2004
- The effects of length of surgery on healing of full and partial thickness flapsJournal of Oral Pathology & Medicine, 1977