Mohammed Jasim Al-Juboori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammed Jasim Al-Juboori has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Akram Hassan
2 shared publicationsShafluzan Bin AbdulRahaman
Department of Oral and Maxillofacial Surgery, University Sains Malaysia, 16150, Kelantan, Malaysia
2 shared publicationsAlyaa Jasim Al-Juboori
1 shared publication- Basma Fathi Alanbari
Al-Rafidain University
1 shared publication Chua M. Hua
1 shared publicationFarah S. Al-Obaidi
1 shared publication
Latest Publications
- Open Access
- 1 November 2018
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. ume 10, 245-249
Treatment of chronic oroantral fistula with platelet-rich fibrin clot and collagen membrane: a case report
An oroantral fistula is a complication of the maxillary posterior teeth that can occur after a tooth extraction that affects the maxillary sinus. Improper management may lead to a persistent fistula, which may become chronic. In this case report, platelet-rich fibrin (PRF) was used with a collagen membrane to close a chronic fistula in a single patient. A flap was raised, the oroantral fistula tract was eliminated, and the opening was closed with a resorbable membrane as a first layer and covered with a PRF clot as a second layer. The flap was closed, and the patient was followed up for suture removal and confirmation of complete soft tissue closure. The postsurgical sign and symptoms of the patient disappeared in the first week; complete tissue healing was detected within 2 weeks, and tissue hypertrophy was observed in the fourth week. The use of PRF may have advantages for soft-tissue healing and for accelerating soft tissue formation by subsequent hypertrophy.
- 1 November 2018
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. ume 10, 245-249
Open AccessTreatment of chronic oroantral fistula with platelet-rich fibrin clot and collagen membrane: a case report
An oroantral fistula is a complication of the maxillary posterior teeth that can occur after a tooth extraction that affects the maxillary sinus. Improper management may lead to a persistent fistula, which may become chronic. In this case report, platelet-rich fibrin (PRF) was used with a collagen membrane to close a chronic fistula in a single patient. A flap was raised, the oroantral fistula tract was eliminated, and the opening was closed with a resorbable membrane as a first layer and covered with a PRF clot as a second layer. The flap was closed, and the patient was followed up for suture removal and confirmation of complete soft tissue closure. The postsurgical sign and symptoms of the patient disappeared in the first week; complete tissue healing was detected within 2 weeks, and tissue hypertrophy was observed in the fourth week. The use of PRF may have advantages for soft-tissue healing and for accelerating soft tissue formation by subsequent hypertrophy.
- Open Access
- 18 October 2018
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 12 (1) , 801-810
Using Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study
Objective: Implants placed in the posterior region of the maxilla have a high incidence of implant failure due to poor bone quality, especially when immediate implant loading is needed. Immediate Progressive Loading (IPL) can enhance bone quality and may offer an alternative solution when Immediate Implant loading is needed. Methods: Six patients (one male and five females; 34-62 years old) were included in this study. Twelve implants were inserted in the posterior region of the maxilla. Resonance Frequency Analysis (RFA) was performed at the time of implant placement and after 1, 2, 3 and 6 months. ISQ (Implant Stability Quotient) values were compared between the Delayed Loading (DL) group after 2 months and the Progressive Loading (PL) group and between different time points for each group. Results: At implant placement, the mean ISQ values for PL and DL implants were 63 and 57, respectively. One month after implant placement, the mean ISQ value for PL implants was 73. Two months after implant placement, the mean ISQ value for PL implants was 75. Three months after implant placement, the mean ISQ values for PL and DL implants were 76 and 69, respectively. Six months after implant placement, the mean ISQ values for PL and DL implants were 79 and 76, respectively. Conclusion: Despite its limitations, this pilot study indicated that compared to DL, PL can enhance bone density and implant stability, resulting in greater early functionality and fewer surgery sessions.
- 18 October 2018
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 12 (1) , 801-810
Open AccessUsing Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study
Objective: Implants placed in the posterior region of the maxilla have a high incidence of implant failure due to poor bone quality, especially when immediate implant loading is needed. Immediate Progressive Loading (IPL) can enhance bone quality and may offer an alternative solution when Immediate Implant loading is needed. Methods: Six patients (one male and five females; 34-62 years old) were included in this study. Twelve implants were inserted in the posterior region of the maxilla. Resonance Frequency Analysis (RFA) was performed at the time of implant placement and after 1, 2, 3 and 6 months. ISQ (Implant Stability Quotient) values were compared between the Delayed Loading (DL) group after 2 months and the Progressive Loading (PL) group and between different time points for each group. Results: At implant placement, the mean ISQ values for PL and DL implants were 63 and 57, respectively. One month after implant placement, the mean ISQ value for PL implants was 73. Two months after implant placement, the mean ISQ value for PL implants was 75. Three months after implant placement, the mean ISQ values for PL and DL implants were 76 and 69, respectively. Six months after implant placement, the mean ISQ values for PL and DL implants were 79 and 76, respectively. Conclusion: Despite its limitations, this pilot study indicated that compared to DL, PL can enhance bone density and implant stability, resulting in greater early functionality and fewer surgery sessions.
- Open Access
- 30 June 2017
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 11 (1) , 284-293
Rotational Flap to Enhance Buccal Gingival Thickness and Implant Emergence Profile in the Esthetic Zone: Two Cases Reports
Objective: Many techniques have been developed to enhance the gingival thickness, gingival level and emergence profile around the implant in the esthetic zone. Introduction: In this study, a buccal rotational flap was used to improve the implant site in the esthetic zone and increase gingival tissue thickness. Methods: Two cases involved the use of a rotational flap during second-stage implant surgery, one case involved the use of a temporary crown with a healing abutment, and another case involved the use of a healing abutment. Result: The cases were followed up until the final crown was placed. The implant site was improved in 2 cases; the gingival thickness increased, the gingival level was enhanced and the emergence profile was developed. Conclusion: Many factors affect the results of a rotational flap; some factors are surgical, while others are prosthetic, biological and anatomical.
- 30 June 2017
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 11 (1) , 284-293
Open AccessRotational Flap to Enhance Buccal Gingival Thickness and Implant Emergence Profile in the Esthetic Zone: Two Cases Reports
Objective: Many techniques have been developed to enhance the gingival thickness, gingival level and emergence profile around the implant in the esthetic zone. Introduction: In this study, a buccal rotational flap was used to improve the implant site in the esthetic zone and increase gingival tissue thickness. Methods: Two cases involved the use of a rotational flap during second-stage implant surgery, one case involved the use of a temporary crown with a healing abutment, and another case involved the use of a healing abutment. Result: The cases were followed up until the final crown was placed. The implant site was improved in 2 cases; the gingival thickness increased, the gingival level was enhanced and the emergence profile was developed. Conclusion: Many factors affect the results of a rotational flap; some factors are surgical, while others are prosthetic, biological and anatomical.
- Open Access
- 21 April 2017
- Published by Ommega Online Publishers in Journal of Dentistry and Oral Care
- Vol. 3 (1) , 1-5
The Relationship between the Lip Length and Smile Line in a Malaysian Population: A Cross-Sectional Study
- 21 April 2017
- Published by Ommega Online Publishers in Journal of Dentistry and Oral Care
- Vol. 3 (1) , 1-5
Open AccessThe Relationship between the Lip Length and Smile Line in a Malaysian Population: A Cross-Sectional Study
- Open Access
- 31 October 2016
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 10 (1) , 561-567
Conservative Socket Regeneration with Buccal Wall Defect Using Guided Tissue
Progressive alveolar bone resorption after tooth extraction may lead to surgical and prosthetic-driven difficulties, especially when deciding to use a dental implant to replace the extracted tooth. This case report discusses an irreparable lower left second premolar tooth with a periodontal lesion on the buccal side. A preservative tooth extraction was performed. Then, the socket was grafted with bovine bone, a collagen membrane was placed between the buccal bone and the attached gingiva, covering the bone dehiscence buccally, and the socket without a flap was raised. After a 6-month healing period, there was minimal socket width resorption and a shallow buccal vestibule. The implant was placed with high primary stability and sufficient buccal plate thickness. In conclusion, this guided tissue regeneration technique can minimize alveolar bone resorption in a socket with buccal dehiscence, but technical difficulties and shallowing of the buccal vestibule still exist.
- 31 October 2016
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 10 (1) , 561-567
Open AccessConservative Socket Regeneration with Buccal Wall Defect Using Guided Tissue
Progressive alveolar bone resorption after tooth extraction may lead to surgical and prosthetic-driven difficulties, especially when deciding to use a dental implant to replace the extracted tooth. This case report discusses an irreparable lower left second premolar tooth with a periodontal lesion on the buccal side. A preservative tooth extraction was performed. Then, the socket was grafted with bovine bone, a collagen membrane was placed between the buccal bone and the attached gingiva, covering the bone dehiscence buccally, and the socket without a flap was raised. After a 6-month healing period, there was minimal socket width resorption and a shallow buccal vestibule. The implant was placed with high primary stability and sufficient buccal plate thickness. In conclusion, this guided tissue regeneration technique can minimize alveolar bone resorption in a socket with buccal dehiscence, but technical difficulties and shallowing of the buccal vestibule still exist.
- Open Access
- 31 March 2016
- Published by Elyns Group LLC in Journal of Dentistry and Orofacial Surgery
- Vol. 1 (2)
Inferior Alveolar Nerve Location to Determine Zone of Safety for Dental Implant Placement among Malaysian Population
- 31 March 2016
- Published by Elyns Group LLC in Journal of Dentistry and Orofacial Surgery
- Vol. 1 (2)
Open AccessInferior Alveolar Nerve Location to Determine Zone of Safety for Dental Implant Placement among Malaysian Population
- Open Access
- 31 July 2015
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 9 (1) , 243-249
The Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period
Purpose: When soft tissue flaps are reflected for implant placement, the blood supply from the periosteum to the bone is disrupted. The aim of this study was to compare the effects of the flapless (FL) and full-thickness flap (FT) techniques on implant stability.Methods:Nine patients received 22 implants. The implants were placed using the FL technique on the contralateral side of the jaw; the FT technique was used as the control technique. Resonance frequency analysis (RFA) was performed at the time of implant placement and at 6 and 12 weeks after implant placement. RFA values were compared between the FL and FT groups and between time intervals in the same group.Results:The median (interquartile range [IQR]) RFA values at the time of implant placement were 75.00 (15.00) for the FL technique and 75.00 (9.00) for the FT technique. At 6 weeks, the median (IQR) values were 79 (3.30) for the FL technique and 80 (12.70) for the FT technique. At 12 weeks, the median (IQR) values were 82.3 (3.30) for the FL technique and 82.6 (8.00) for the FT technique. There were no significant differences between the 2 techniques at the time of implant placement, after 6 weeks or after 12 weeks, with p values of 0.994, 0.789, and 0.959, respectively. There were significant differences between the RFA values at the time of implant placement and after 6 weeks for the FL technique (p=0.028) but not for the FT technique (p=0.091). There were also significant differences between the RFA values at 6 weeks and the RFA values at 12 weeks for the FL technique (p=0.007) and for the FT technique (p=0.003).Conclusion:Periosteum preservation during the FL procedure will speed up bone remodeling and result in early secondary implant stability as well as early loading.
- 31 July 2015
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 9 (1) , 243-249
Open AccessThe Effect of Flapless and Full-thickness Flap Techniques on Implant Stability During the Healing Period
Purpose: When soft tissue flaps are reflected for implant placement, the blood supply from the periosteum to the bone is disrupted. The aim of this study was to compare the effects of the flapless (FL) and full-thickness flap (FT) techniques on implant stability.Methods:Nine patients received 22 implants. The implants were placed using the FL technique on the contralateral side of the jaw; the FT technique was used as the control technique. Resonance frequency analysis (RFA) was performed at the time of implant placement and at 6 and 12 weeks after implant placement. RFA values were compared between the FL and FT groups and between time intervals in the same group.Results:The median (interquartile range [IQR]) RFA values at the time of implant placement were 75.00 (15.00) for the FL technique and 75.00 (9.00) for the FT technique. At 6 weeks, the median (IQR) values were 79 (3.30) for the FL technique and 80 (12.70) for the FT technique. At 12 weeks, the median (IQR) values were 82.3 (3.30) for the FL technique and 82.6 (8.00) for the FT technique. There were no significant differences between the 2 techniques at the time of implant placement, after 6 weeks or after 12 weeks, with p values of 0.994, 0.789, and 0.959, respectively. There were significant differences between the RFA values at the time of implant placement and after 6 weeks for the FL technique (p=0.028) but not for the FT technique (p=0.091). There were also significant differences between the RFA values at 6 weeks and the RFA values at 12 weeks for the FL technique (p=0.007) and for the FT technique (p=0.003).Conclusion:Periosteum preservation during the FL procedure will speed up bone remodeling and result in early secondary implant stability as well as early loading.
- 1 May 2015
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 16 (5) , 422-426
Interdental Implant Papillae Grow up with Temporary Abutment displaced at Monthly Intervals
Interdental papillae regeneration remains a challenge in implant dentistry in cases in which papillae are lost following tooth extraction. This report presents an implant case with missing 1st and 2nd premolars and total papillary loss. We performed immediate provisionalization to the first premolar implant with a temporary abutment and crown, whereas the second premolar was submerged. Crown contouring and modifications to the shape and size were performed once every month (the temporary abutment and crown disconnected three times during the 3-month healing period). At the end of the 3-month healing period, papillae regeneration was observed between the implant and the adjacent tooth and between the adjacent implants. Papillae regeneration is possible with temporary abutment and a composite material crown that is properly contoured and polished, even with several abutment removals during the healing period. How to cite this article AL-Juboori MJ. Interdental Implant Papillae Grow up with Temporary Abutment displaced at Monthly Intervals. J Contemp Dent Pract 2015;16(5):422-426.
- 1 May 2015
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 16 (5) , 422-426
Interdental Implant Papillae Grow up with Temporary Abutment displaced at Monthly Intervals
Interdental papillae regeneration remains a challenge in implant dentistry in cases in which papillae are lost following tooth extraction. This report presents an implant case with missing 1st and 2nd premolars and total papillary loss. We performed immediate provisionalization to the first premolar implant with a temporary abutment and crown, whereas the second premolar was submerged. Crown contouring and modifications to the shape and size were performed once every month (the temporary abutment and crown disconnected three times during the 3-month healing period). At the end of the 3-month healing period, papillae regeneration was observed between the implant and the adjacent tooth and between the adjacent implants. Papillae regeneration is possible with temporary abutment and a composite material crown that is properly contoured and polished, even with several abutment removals during the healing period. How to cite this article AL-Juboori MJ. Interdental Implant Papillae Grow up with Temporary Abutment displaced at Monthly Intervals. J Contemp Dent Pract 2015;16(5):422-426.
- Open Access
- 1 January 2015
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. 7, 25-31
Progressive immediate loading of a perforated maxillary sinus dental implant: a case report
The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement.
- 1 January 2015
- Published by Taylor & Francis in Clinical, Cosmetic and Investigational Dentistry
- Vol. 7, 25-31
Open AccessProgressive immediate loading of a perforated maxillary sinus dental implant: a case report
The displacement of a dental implant into the maxillary sinus may lead to implant failure due to exposure of the apical third or the tip of the implant beyond the bone, resulting in soft tissue growth. This case report discusses dental implant placement in the upper first molar area with maxillary sinus involvement of approximately 2 mm. A new technique for progressive implant loading was used, involving immediately loaded implants with maxillary sinus perforation and low primary stability. Follow-up was performed with resonance frequency analysis and compared with an implant placed adjacent in the upper second premolar area using a conventional delayed loading protocol. Implants with maxillary sinus involvement showed increasing stability during the healing period. We found that progressive implant loading may be a safe technique for the placement of immediately loaded implants with maxillary sinus involvement.
- 1 August 2013
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 22 (4) , 351-355
The Correlation Between Crestal Bone Resorption and Implant Stability During Healing Period Using Resonance Frequency Analysis
To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA). Twenty-two International Team for Implantology Straumann implants were placed in the posterior maxilla or mandible in 9 patients. RFA reading was taken immediately after implant placement. Periapical radiographs were taken, and the distance from the shoulder of the healing cap to the first bone-implant contact was measured, and the average mesial and distal distances were taken. Patients were followed up at 6 and 12 weeks for data collection. At 6 weeks, the correlation between crestal bone resorption and implant stability was significant (Spearman correlation test, P < 0.05) and negative correlation coefficient (r) was -0.522. At 12 weeks, the correlation between crestal bone resorption and implant stability was not significant (Spearman correlation test, P > 0.05) and negative correlation coefficient (r) was -0.119. There was a significant negative correlation between the crestal bone resorption and implant stability at 6 weeks, whereas the negative correlations between the crestal bone resorption and implant stability at 12 weeks were nonsignificant.
- 1 August 2013
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 22 (4) , 351-355
The Correlation Between Crestal Bone Resorption and Implant Stability During Healing Period Using Resonance Frequency Analysis
To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA). Twenty-two International Team for Implantology Straumann implants were placed in the posterior maxilla or mandible in 9 patients. RFA reading was taken immediately after implant placement. Periapical radiographs were taken, and the distance from the shoulder of the healing cap to the first bone-implant contact was measured, and the average mesial and distal distances were taken. Patients were followed up at 6 and 12 weeks for data collection. At 6 weeks, the correlation between crestal bone resorption and implant stability was significant (Spearman correlation test, P < 0.05) and negative correlation coefficient (r) was -0.522. At 12 weeks, the correlation between crestal bone resorption and implant stability was not significant (Spearman correlation test, P > 0.05) and negative correlation coefficient (r) was -0.119. There was a significant negative correlation between the crestal bone resorption and implant stability at 6 weeks, whereas the negative correlations between the crestal bone resorption and implant stability at 12 weeks were nonsignificant.