Components of compression splice resistances in high-strength concrete
Author:
- 1 May 2017
- journal article
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 69 (10) , 502-511
Abstract
To investigate the development of compression splice resistances, compression splices under normal conditions, splices with bond only and splices with bearing only were tested. The bond and bearing strengths of the normal splices were found to be less than those of splices with bond only and splices with bearing only, respectively, because in the normal splices the circumferential tensile stresses induced by bearing and bond overlapped at the ends of the splice length. However, the strengths of the normal splices are always higher than the strengths of the bond only or bearing only splices because the normal splices exhibit less slip compared to the bond only or bearing only splices at the same level of bar stress. Consequently, the splice strength in compression cannot be improved by removing either the bond or the bearing. In addition, the bond strength in the bond only splices is nearly the same as the bond strength in tension splices.Keywords
This publication has 5 references indexed in Scilit:
- The influence of high-strength concrete – rebars bond conditions on the mechanism of its failureMagazine of Concrete Research, 2017
- Steel–concrete bond behaviour of self-compacting concrete with recycled aggregatesMagazine of Concrete Research, 2016
- Experimental Evaluation of Bearing and Bond Strengths in Compression SplicesJournal of the Korea Concrete Institute, 2012
- Simplified Design Equation of Lap Splice Length in CompressionInternational Journal of Concrete Structures and Materials, 2010
- Behavior and Capacity of Compression Lap Splice in Unconfined Concrete with Compressive Strength of 40 and 60 MPaJournal of the Korea Concrete Institute, 2009