Sung-Chul Chun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sung-Chul Chun has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Sung-Ho Lee
1 Architectural Engineering Research Team, Daewoo E&C, Seoul, Korea
9 shared publications Bohwan Oh
6 shared publications- Tae-Hun Ha
Principal Researcher, Architectural Engineering Research Team, Daewoo Institute of Construction Technology, 20 Suil-ro 123, Jangan-gu, Suwon 16297, South Korea
4 shared publications Bo-Hwan Oh
2 shared publicationsSo-Young Tak
2 shared publicationsSung-Gul Hong
2 shared publications
Latest Publications
- 1 February 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (2) , 04022233
Side-Face Blowout Strength of Large-Diameter High-Strength Headed Bars in a Single Layer or Two Layers Terminated within Exterior Beam–Column Joints
Due to a lack of test data on large-diameter headed bars, design provisions limit the bar diameter of headed bars to 36 mm or less. In exterior beam–column joints with two-layer headed bars as beam bars, if the layer-to-layer spacing of the headed bars is narrow, the side-face blowout area of an individual headed bar is overlapped. Existing design provisions do not consider the effects of layer-to-layer spacing. In this study, 34 simulated exterior beam–column joints were tested to examine the effects of bar diameters over the limitation of existing design provisions using large-diameter (41- and 51-mm) headed bars. The side-face blowout strengths of the two-layer headed bars were experimentally investigated through simulated exterior beam–column joints with layer-to-layer spacing of (two times the bar diameter). The test results showed that the side-face blowout strengths had the same characteristics for bar diameters from 22 to 51 mm. For the two-layer headed bars, crack propagation and failure mode were the same as those for single-layer headed bars, but due to the overlap of the blowout area, the strength of the individual headed bar was reduced. A new model was proposed to predict the side-face blowout strengths of large-diameter high-strength headed bars in both a single layer and in two layers by incorporating a spacing factor for an individual headed bar into a model from the literature. A total of 173 test results from this study and previous studies were compared with predictions from the proposed model, and the average and coefficient of variation (COV) of test-to-prediction ratios were 1.08 and 17.4 %, respectively.- 1 February 2023
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 149 (2) , 04022233
Side-Face Blowout Strength of Large-Diameter High-Strength Headed Bars in a Single Layer or Two Layers Terminated within Exterior Beam–Column Joints
Due to a lack of test data on large-diameter headed bars, design provisions limit the bar diameter of headed bars to 36 mm or less. In exterior beam–column joints with two-layer headed bars as beam bars, if the layer-to-layer spacing of the headed bars is narrow, the side-face blowout area of an individual headed bar is overlapped. Existing design provisions do not consider the effects of layer-to-layer spacing. In this study, 34 simulated exterior beam–column joints were tested to examine the effects of bar diameters over the limitation of existing design provisions using large-diameter (41- and 51-mm) headed bars. The side-face blowout strengths of the two-layer headed bars were experimentally investigated through simulated exterior beam–column joints with layer-to-layer spacing of (two times the bar diameter). The test results showed that the side-face blowout strengths had the same characteristics for bar diameters from 22 to 51 mm. For the two-layer headed bars, crack propagation and failure mode were the same as those for single-layer headed bars, but due to the overlap of the blowout area, the strength of the individual headed bar was reduced. A new model was proposed to predict the side-face blowout strengths of large-diameter high-strength headed bars in both a single layer and in two layers by incorporating a spacing factor for an individual headed bar into a model from the literature. A total of 173 test results from this study and previous studies were compared with predictions from the proposed model, and the average and coefficient of variation (COV) of test-to-prediction ratios were 1.08 and 17.4 %, respectively.- 15 December 2018
- Published by Korean Association for Spatial Structures in Journal of the Korean Association for Spatial Structures
- Vol. 18 (4) , 61-68
Tensile Strength of Post-Installed High-Shear Ring Anchors (HRA) After Shear Loading
- 15 December 2018
- Published by Korean Association for Spatial Structures in Journal of the Korean Association for Spatial Structures
- Vol. 18 (4) , 61-68
Tensile Strength of Post-Installed High-Shear Ring Anchors (HRA) After Shear Loading
- Open Access
Effect of Calcium Carbonate Fineness on Calcium Sulfoaluminate-Belite Cement
This study investigated the hydration characteristics and strength development of calcium sulfoaluminate-belite (CSAB) cements incorporating calcium carbonate (CC) powders with various particle size distributions and different gypsum amounts. In general, the CSAB hydration was accelerated by the CC powder, but the acceleration and resulting strength improvement were more effective with finer CC powder. Regardless of the fineness of the CC powder, it took part in the hydration of CSAB cement, forming hemicarboaluminate and monocarboaluminate phases. These hydration and nucleation effects compensated for the strength reduction from decreased cementing components (i.e., dilution effect) when finer CC powders were used, while they did not overcome the strength reduction when coarser CC powder was used. On the other hand, increasing the amount of gypsum for a given CC content improved the strength. The strength of CSAB cement had a clear inverse relationship with its total pore volume measured by mercury intrusion porosimetry (MIP). Thermodynamic modeling for CSAB cement hydration showed that the use of CC powder increased total volume of solid phases up to 6 wt % at a given amount of gypsum.
Open AccessEffect of Calcium Carbonate Fineness on Calcium Sulfoaluminate-Belite Cement
This study investigated the hydration characteristics and strength development of calcium sulfoaluminate-belite (CSAB) cements incorporating calcium carbonate (CC) powders with various particle size distributions and different gypsum amounts. In general, the CSAB hydration was accelerated by the CC powder, but the acceleration and resulting strength improvement were more effective with finer CC powder. Regardless of the fineness of the CC powder, it took part in the hydration of CSAB cement, forming hemicarboaluminate and monocarboaluminate phases. These hydration and nucleation effects compensated for the strength reduction from decreased cementing components (i.e., dilution effect) when finer CC powders were used, while they did not overcome the strength reduction when coarser CC powder was used. On the other hand, increasing the amount of gypsum for a given CC content improved the strength. The strength of CSAB cement had a clear inverse relationship with its total pore volume measured by mercury intrusion porosimetry (MIP). Thermodynamic modeling for CSAB cement hydration showed that the use of CC powder increased total volume of solid phases up to 6 wt % at a given amount of gypsum.
- 1 May 2017
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 69 (10) , 502-511
Components of compression splice resistances in high-strength concrete
To investigate the development of compression splice resistances, compression splices under normal conditions, splices with bond only and splices with bearing only were tested. The bond and bearing strengths of the normal splices were found to be less than those of splices with bond only and splices with bearing only, respectively, because in the normal splices the circumferential tensile stresses induced by bearing and bond overlapped at the ends of the splice length. However, the strengths of the normal splices are always higher than the strengths of the bond only or bearing only splices because the normal splices exhibit less slip compared to the bond only or bearing only splices at the same level of bar stress. Consequently, the splice strength in compression cannot be improved by removing either the bond or the bearing. In addition, the bond strength in the bond only splices is nearly the same as the bond strength in tension splices.
- 1 May 2017
- Published by Emerald Publishing in Magazine of Concrete Research
- Vol. 69 (10) , 502-511
Components of compression splice resistances in high-strength concrete
To investigate the development of compression splice resistances, compression splices under normal conditions, splices with bond only and splices with bearing only were tested. The bond and bearing strengths of the normal splices were found to be less than those of splices with bond only and splices with bearing only, respectively, because in the normal splices the circumferential tensile stresses induced by bearing and bond overlapped at the ends of the splice length. However, the strengths of the normal splices are always higher than the strengths of the bond only or bearing only splices because the normal splices exhibit less slip compared to the bond only or bearing only splices at the same level of bar stress. Consequently, the splice strength in compression cannot be improved by removing either the bond or the bearing. In addition, the bond strength in the bond only splices is nearly the same as the bond strength in tension splices.
- Open Access
- 15 November 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (7) , 4563-4573
Cyclic testing of reinforced concrete columns with double or one-side headed shear reinforcement
The effectiveness of single-leg crossties that were anchored by heads in reinforced concrete columns was assessed. Seven reinforced concrete columns were tested under reversed cyclic loading with a 10 % axial load of the nominal axial capacity of the columns. Four columns were designed to fail in a flexural mode, and three columns were designed to fail in a shear mode. The main variable was the anchorage type of crossties: conventional crossties that were anchored with 135° and 90° hooks, crossties that were anchored with one-side head and one-side 180° hook, and crossties that were anchored with double heads. The test results indicate that the hysteretic behavior of the columns with crossties that were anchored by double heads or one-side head was similar or superior to the columns with conventional crossties anchored by hooks in terms of ductility and energy dissipation. After the cover concrete spalled, the 90° hooks inevitably opened and the column longitudinal bars buckled. However, the heads could delay the buckling of the column bars and the columns could maintain their capacities until 8 % drift ratio for the columns that were designed to fail in a flexural mode. For the columns that were designed to fail in a shear mode, all columns showed similar behaviors and had identical strengths. The columns with the headed crossties had smaller crack widths than the columns with conventional crossties because the headed crossties well confined the core concrete under severe shear deformation. The test results show that headed crossties can effectively confine the column bars and core concrete of the columns: therefore, the ductility and energy dissipation capacity of the columns were improved.
- 15 November 2016
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 18 (7) , 4563-4573
Open AccessCyclic testing of reinforced concrete columns with double or one-side headed shear reinforcement
The effectiveness of single-leg crossties that were anchored by heads in reinforced concrete columns was assessed. Seven reinforced concrete columns were tested under reversed cyclic loading with a 10 % axial load of the nominal axial capacity of the columns. Four columns were designed to fail in a flexural mode, and three columns were designed to fail in a shear mode. The main variable was the anchorage type of crossties: conventional crossties that were anchored with 135° and 90° hooks, crossties that were anchored with one-side head and one-side 180° hook, and crossties that were anchored with double heads. The test results indicate that the hysteretic behavior of the columns with crossties that were anchored by double heads or one-side head was similar or superior to the columns with conventional crossties anchored by hooks in terms of ductility and energy dissipation. After the cover concrete spalled, the 90° hooks inevitably opened and the column longitudinal bars buckled. However, the heads could delay the buckling of the column bars and the columns could maintain their capacities until 8 % drift ratio for the columns that were designed to fail in a flexural mode. For the columns that were designed to fail in a shear mode, all columns showed similar behaviors and had identical strengths. The columns with the headed crossties had smaller crack widths than the columns with conventional crossties because the headed crossties well confined the core concrete under severe shear deformation. The test results show that headed crossties can effectively confine the column bars and core concrete of the columns: therefore, the ductility and energy dissipation capacity of the columns were improved.
- 30 June 2014
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 26 (3) , 385-392
Evaluation of Construction Loads of Slabs and Shores with Removing Shores and Placing Reshores
- 30 June 2014
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 26 (3) , 385-392
Evaluation of Construction Loads of Slabs and Shores with Removing Shores and Placing Reshores
- 30 June 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (3) , 275-283
Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices
- 30 June 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (3) , 275-283
Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices
- 30 April 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (2) , 195-204
Mechanical Properties and Stress-Strain Model of Re-Bars Coldly Bent and Straightened
- 30 April 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (2) , 195-204
Mechanical Properties and Stress-Strain Model of Re-Bars Coldly Bent and Straightened
- 30 April 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (2) , 129-136
Experimental Evaluation of Bearing and Bond Strengths in Compression Splices
- 30 April 2012
- Published by Korea Concrete Institute in Journal of the Korea Concrete Institute
- Vol. 24 (2) , 129-136
Experimental Evaluation of Bearing and Bond Strengths in Compression Splices