Optimization of the design of a single-sided magnetic resonance magnet array for improved T2 estimation accuracy
- 30 December 2024
- journal article
- research article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (1) , 015908
Abstract
Single-sided magnetic resonance (SSMR) technology has a compact structure and great potential for use in mobile and nondestructive detection of large aqueous materials. As the detection depth increases, the magnetic field gradient generated by the magnetic resonance magnet placed on one side weakens, leading to a large distortion of T 2, thereby significantly impeding accurate estimation of the pore size distribution within the detection target. In this study, to address this problem, the distortion in the region of interest (ROI) is significantly reduced by optimizing the size and arrangement of the SSMR magnet array. First, to evaluate the T 2 distortion within the ROI, we developed a T 2 distortion loss function based on α and θ, which are key parameters of the spin echo (SE) signal. We then combined the nonlinear constraints with the loss function to form a Lagrangian function, which was solved via the Newton iteration method to obtain the magnet array parameters. The magnet array is called the AT magnet array. The T 2 distortion was quantitatively evaluated by calculating the SE signal generated by the AT magnet array in the ROI. Furthermore, we compared the detection results obtained with the AT and the semi-annular (SA) magnet array. The results showed that within the 3 cm × 3 cm target range of a 10 cm depth, the AT magnet array had a smaller T 2 distortion of only 1.3%. After the ROI was expanded to 5 cm × 5 cm, the T 2 distortion of the SE signal measured by the AT magnet array was 6%, which met the SSMR detection accuracy requirements in this range. Therefore, the optimized design of the magnet array based on α and θ provides a theoretical basis for obtaining SE signals with low T 2 distortion at large depths and over large areas via SSMR.Keywords
Funding Information
- National Natural Science Foundation of China (No. 42072291)
- National Major Scientific Instruments and Equipments Development Project of National Natural Science Foundation of China (No. 42127807)
This publication has 33 references indexed in Scilit:
- Practical Concepts for Design, Construction and Application of Halbach Magnets in Magnetic ResonanceApplied Magnetic Resonance, 2023
- An optimized UMR sensor for non-destructive measurements of moisture in woodApplied Physics A, 2022
- In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach arrayMagnetic Resonance in Medicine, 2020
- Aging of polymeric materials by stray‐field NMR relaxometry with the NMR‐MOUSEConcepts in Magnetic Resonance Part A, 2018
- A portable single‐sided magnet system for remote NMR measurements of pulmonary functionNMR in Biomedicine, 2014
- A portable NMR sensor for moisture monitoring of wooden works of art, particularly of paintings on woodWood Science and Technology, 2008
- A compact permanent magnet array with a remote homogeneous fieldJournal of Magnetic Resonance, 2007
- A constant gradient unilateral magnet for near-surface MRI profilingJournal of Magnetic Resonance, 2006
- 3D imaging with a single-sided sensor: an open tomographJournal of Magnetic Resonance, 2004
- Categories of Coherence Pathways for the CPMG SequenceJournal of Magnetic Resonance, 2002