Comparison of the Point‐by‐Point versus Catheter Dragging Technique for Curative Radiofrequency Ablation of Atrial Fibrillation
- 28 October 2010
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (1) , 15-22
Abstract
Background: The relationship between the applied techniques and clinical outcomes after radiofrequency (RF) ablation of atrial fibrillation (AF) remains unclear. We compared the results of ablation by RF delivered via a point‐by‐point versus catheter dragging technique for the treatment of AF. Methods: This study included 66 patients with drug‐refractory AF who underwent circumferential pulmonary vein (PV) ablation. A point‐by‐point technique was used in 35 (53%) patients (Group I), and catheter dragging technique in the remaining 31 (47%) patients (Group II). If AF persisted or remained inducible after the PV isolation, additional ablation of complex fractionated atrial electrograms and linear ablation were performed. Results: Significantly, fewer RF applications were delivered in Group II than in Group I. The total RF energy duration delivered was comparable between the two groups (P = 0.55). However, the total energy of RF deliveries was significantly greater in Group II than in Group I (P = 0.02). Despite a longer fluoroscopic exposure time (P = 0.01), the total procedural duration was significantly shorter in Group II than in Group I (P = 0.005). Within 3 months after a single ablation procedure, 24 patients (69%) in Group I versus 13 patients (42%) in Group II had ≥1 recurrence(s) of atrial tachyarrhythmias (P = 0.03). A multivariate analysis showed that a point‐by‐point ablation was the only independent predictor of early atrial tachyarrhythmia recurrences. Conclusions: The catheter dragging technique for ablation of AF was associated with a lower early recurrence rate of atrial tachyarrhythmias than the point‐by‐point technique. (PACE 2011; 15–22)Keywords
This publication has 23 references indexed in Scilit:
- Impact of Heart Rhythm Status on Registration Accuracy of the Left Atrium for Catheter Ablation of Atrial FibrillationJournal of Cardiovascular Electrophysiology, 2007
- Efficacy and late recurrences with wide electrical pulmonary vein isolation for persistent and permanent atrial fibrillationEP Europace, 2007
- Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex ElectrogramsCirculation, 2007
- The effectiveness of a high output/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillationEP Europace, 2006
- Effects of Gap Geometry on Conduction Through Discontinuous Radiofrequency LesionsCirculation, 2006
- Response of Atrial Fibrillation to Pulmonary Vein Antrum Isolation Is Directly Related to Resumption and Delay of Pulmonary Vein ConductionCirculation, 2005
- Effects of Pulmonary Vein Ablation on Regional Atrial Vagal Innervation and Vulnerability to Atrial Fibrillation in DogsJournal of Cardiovascular Electrophysiology, 2005
- Left Atrial Flutter Following Pulmonary Vein Antrum Isolation with Radiofrequency Energy: Linear Lesions or Repeat IsolationJournal of Cardiovascular Electrophysiology, 2005
- Noninducibility of Atrial Fibrillation as an End Point of Left Atrial Circumferential Ablation for Paroxysmal Atrial FibrillationCirculation, 2004
- Clinical significance of early recurrences of atrial fibrillation after pulmonary vein isolationJACC, 2002