Miki Yokokawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miki Yokokawa has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Anil K. Bhandari
Division of Cardiology, Good Samaritan Hospital, Los Angeles, California
1 shared publicationAtsushi Suzuki
Division of Cardiology, Good Samaritan Hospital, Los Angeles, California
1 shared publicationDavid S. Cannom
Division of Cardiology, Good Samaritan Hospital, Los Angeles, California
1 shared publication- Hideo Okamura
Department of Cardiovascular Medicine, National Cerebral and Cardiovascular Center
1 shared publication - Hiroshi Tada
Cardiovascular Division, Institute of Clinical Medicine, Graduate School of Comprehensive Human Sciences, University of Tsukuba, Ibaraki, Japan
1 shared publication Ivan Ho
Division of Cardiology, Good Samaritan Hospital, Los Angeles, California
1 shared publication
Latest Publications
- 28 October 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (1) , 15-22
Comparison of the Point‐by‐Point versus Catheter Dragging Technique for Curative Radiofrequency Ablation of Atrial Fibrillation
Background: The relationship between the applied techniques and clinical outcomes after radiofrequency (RF) ablation of atrial fibrillation (AF) remains unclear. We compared the results of ablation by RF delivered via a point‐by‐point versus catheter dragging technique for the treatment of AF. Methods: This study included 66 patients with drug‐refractory AF who underwent circumferential pulmonary vein (PV) ablation. A point‐by‐point technique was used in 35 (53%) patients (Group I), and catheter dragging technique in the remaining 31 (47%) patients (Group II). If AF persisted or remained inducible after the PV isolation, additional ablation of complex fractionated atrial electrograms and linear ablation were performed. Results: Significantly, fewer RF applications were delivered in Group II than in Group I. The total RF energy duration delivered was comparable between the two groups (P = 0.55). However, the total energy of RF deliveries was significantly greater in Group II than in Group I (P = 0.02). Despite a longer fluoroscopic exposure time (P = 0.01), the total procedural duration was significantly shorter in Group II than in Group I (P = 0.005). Within 3 months after a single ablation procedure, 24 patients (69%) in Group I versus 13 patients (42%) in Group II had ≥1 recurrence(s) of atrial tachyarrhythmias (P = 0.03). A multivariate analysis showed that a point‐by‐point ablation was the only independent predictor of early atrial tachyarrhythmia recurrences. Conclusions: The catheter dragging technique for ablation of AF was associated with a lower early recurrence rate of atrial tachyarrhythmias than the point‐by‐point technique. (PACE 2011; 15–22)
- 28 October 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (1) , 15-22
Comparison of the Point‐by‐Point versus Catheter Dragging Technique for Curative Radiofrequency Ablation of Atrial Fibrillation
Background: The relationship between the applied techniques and clinical outcomes after radiofrequency (RF) ablation of atrial fibrillation (AF) remains unclear. We compared the results of ablation by RF delivered via a point‐by‐point versus catheter dragging technique for the treatment of AF. Methods: This study included 66 patients with drug‐refractory AF who underwent circumferential pulmonary vein (PV) ablation. A point‐by‐point technique was used in 35 (53%) patients (Group I), and catheter dragging technique in the remaining 31 (47%) patients (Group II). If AF persisted or remained inducible after the PV isolation, additional ablation of complex fractionated atrial electrograms and linear ablation were performed. Results: Significantly, fewer RF applications were delivered in Group II than in Group I. The total RF energy duration delivered was comparable between the two groups (P = 0.55). However, the total energy of RF deliveries was significantly greater in Group II than in Group I (P = 0.02). Despite a longer fluoroscopic exposure time (P = 0.01), the total procedural duration was significantly shorter in Group II than in Group I (P = 0.005). Within 3 months after a single ablation procedure, 24 patients (69%) in Group I versus 13 patients (42%) in Group II had ≥1 recurrence(s) of atrial tachyarrhythmias (P = 0.03). A multivariate analysis showed that a point‐by‐point ablation was the only independent predictor of early atrial tachyarrhythmia recurrences. Conclusions: The catheter dragging technique for ablation of AF was associated with a lower early recurrence rate of atrial tachyarrhythmias than the point‐by‐point technique. (PACE 2011; 15–22)
- 5 March 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (7) , e62-e64
Radiofrequency Catheter Ablation of Parasystole Originating from the Inferior Vena Cava
- 5 March 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (7) , e62-e64
Radiofrequency Catheter Ablation of Parasystole Originating from the Inferior Vena Cava