CZE separation of amitrol and triazine herbicides in environmental water samples with acid‐assisted on‐column preconcentration
- 10 December 2010
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 32 (2) , 275-283
Abstract
A simple analytical scheme for the detection and quantification of amitrol and triazine herbicides (atrazine, ametryn and atraton) and degradation product (2‐hydroxyatrazine) in environmental water samples by CZE is reported. On‐column preconcentration of analytes from untreated water samples (mineral, spring, tap and river water) is accomplished by introducing an acid plug (200 mM citrate of pH 2.0) after the sample and then proceeding with the CZE separation, using 100 mM formiate buffer of pH 3.5 as running buffer and 25.0 KV as separation voltage. UV detection at 200 nm provides LODs from 50 to 300 nM in untreated samples and they were lowered tenfold by sample preconcentration by evaporation. Calculated recoveries were typically higher than 90%. Minimal detectable concentration of the electroactive amitrol could be decreased about 20‐fold when electrochemical detection was employed by monitoring the amperometric signal at +800 mV using a carbon paste electrode (LOD of 9.6 nM, 0.81 μg/L, versus 170 nM, 14.3 μg/L, using amperometric and UV detection, respectively) in untreated water samples.Keywords
This publication has 33 references indexed in Scilit:
- Amino Acid Profile Determination in the Urine of Bladder Cancer Patients by CE-MS with On-Line pH-Mediated Stacking and Pattern RecognitionChromatographia, 2009
- Determination of Amitrole in Environmental Water Samples with Precolumn Derivatization by High-Performance Liquid ChromatographyJournal of Agricultural and Food Chemistry, 2009
- Determination of triazine herbicide residues in water samples by on-line sweeping concentration in micellar electrokinetic chromatographyChinese Chemical Letters, 2008
- Capillary Electrophoresis-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry for the Identification of Cationic Metabolites via a pH-Mediated Stacking-Transient Isotachophoretic MethodAnalytical Chemistry, 2008
- Enhanced pH‐mediated stacking of anions for CE incorporating a dynamic pH junctionElectrophoresis, 2007
- Carbon nanotubes paste electrodes as new detectors for capillary electrophoresisAnalytica Chimica Acta, 2005
- pH-mediated acid stacking with reverse pressure for the analysis of cationic pharmaceuticals in capillary electrophoresisElectrophoresis, 2005
- Determination of 3-amino-1,2,4-triazole (amitrole) in environmental waters by capillary electrophoresisTalanta, 2003
- On-line concentration in micellar electrokinetic chromatography for triazine determination in water samples: evaluation of three different stacking modesThe Analyst, 2000
- Comparison of on-line enrichment based on ion-pair and cation-exchange liquid chromatography for the trace-level determination of 3-amino-1,2,4-triazole (aminotriazole) in waterAnalytica Chimica Acta, 1993