Alberto Sánchez Arribas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alberto Sánchez Arribas has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Chicharro
Dpto. Química Analítica y Análisis Instrumental, Universidad Autónoma de Madrid, C/Francisco Tomás y Valiente 7, Madrid, Spain
12 shared publications Antonio Zapardiel
Dpto. Ciencias Analíticas. Universidad Nacional de Educación a Distancia. P° Senda del Rey 9 Madrid Spain
11 shared publicationsEsperanza Bermejo
Dpto. Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid. C/Francisco Tomás y Valiente 7 Madrid Spain
11 shared publicationsMónica Moreno
Dpto. Química Analítica y Análisis Instrumental Universidad Autónoma de Madrid. C/Francisco Tomás y Valiente 7 Madrid Spain
7 shared publications- Guillermina Leticia Luque
Department of Physical Chemistry, Faculty of Chemical Sciences, National University of Córdoba (UNC), Córdoba, Argentina
2 shared publications Gustavo A. Rivas
2 shared publications
Latest Publications
- 6 April 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1461-1471
Characterization of White Wines by Electrochemical Indexes Obtained Using Carbon Nanotube‐modified Electrodes
In this study, the development of a fast electroanalytical method for the characterization of wines through the evaluation of their phenolic content has been reported. A critical analysis of the influence of some experimental conditions on the efficient dispersion of carbon nanotubes (CNT) in water was carried out. The selected procedure consisted of: 1) 2.0 mg CNT were dispersed in 4.0 mL of 0.25 % (w/v) PEI solution by ultrasonic treatment of 2000‐J energy; 2) dispersions were centrifuged at 2500 rpm for 20 min and sedimented CNT were subsequently washed with pure water; and 3) recovered CNT were re‐dispersed in 4.0 mL of water by ultrasonic treatment of 2000‐J energy. Glassy carbon electrodes modified with CNT films produced from these dispersions showed excellent electrochemical performance for the detection of different polyphenols usually found in wine using flow injection analysis, with good sensitivity, wide linear range and excellent stability. This behaviour allowed the estimation of total polyphenol content in white wines with a remarkable long‐term stability in the measurements. In addition, different polyphenols fractions, expressed as “electrochemical indexes” (EI), can be obtained just by tuning the detection potential. These EI might be employed as characteristic markers of wines related to grape varietal, with potential application for classification purposes as suggested after the analysis of white wines produced using “verdejo” and “airén” grapes.
- 6 April 2018
- Published by Wiley in Electroanalysis
- Vol. 30 (7) , 1461-1471
Characterization of White Wines by Electrochemical Indexes Obtained Using Carbon Nanotube‐modified Electrodes
In this study, the development of a fast electroanalytical method for the characterization of wines through the evaluation of their phenolic content has been reported. A critical analysis of the influence of some experimental conditions on the efficient dispersion of carbon nanotubes (CNT) in water was carried out. The selected procedure consisted of: 1) 2.0 mg CNT were dispersed in 4.0 mL of 0.25 % (w/v) PEI solution by ultrasonic treatment of 2000‐J energy; 2) dispersions were centrifuged at 2500 rpm for 20 min and sedimented CNT were subsequently washed with pure water; and 3) recovered CNT were re‐dispersed in 4.0 mL of water by ultrasonic treatment of 2000‐J energy. Glassy carbon electrodes modified with CNT films produced from these dispersions showed excellent electrochemical performance for the detection of different polyphenols usually found in wine using flow injection analysis, with good sensitivity, wide linear range and excellent stability. This behaviour allowed the estimation of total polyphenol content in white wines with a remarkable long‐term stability in the measurements. In addition, different polyphenols fractions, expressed as “electrochemical indexes” (EI), can be obtained just by tuning the detection potential. These EI might be employed as characteristic markers of wines related to grape varietal, with potential application for classification purposes as suggested after the analysis of white wines produced using “verdejo” and “airén” grapes.
- 10 October 2017
- Published by Elsevier in Applied Materials Today
- Vol. 9, 456-481
Carbon nanotubes as analytical tools in capillary electromigration methods
- 10 October 2017
- Published by Elsevier in Applied Materials Today
- Vol. 9, 456-481
Carbon nanotubes as analytical tools in capillary electromigration methods
- 1 March 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (11) , 1693-1700
Classification of Spanish white wines using their electrophoretic profiles obtained by capillary zone electrophoresis with amperometric detection
A method was developed for the simultaneous detection of eight polyphenols (t‐resveratrol, (+)‐catechin, quercetin and p‐coumaric, caffeic, sinapic, ferulic, and gallic acids) by CZE with electrochemical detection. Separation of these polyphenols was achieved within 25 min using a 200 mM borate buffer (pH 9.4) containing 10% methanol as separation electrolyte. Amperometric detection of polyphenols was carried out with a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (CNT) layer obtained from a dispersion of CNT in polyethylenimine. The excellent electrochemical properties of this modified electrode allowed the detection and quantification of the selected polyphenols in white wines without any pretreatment step, showing remarkable signal stability despite the presence of potential fouling substances in wine. The electrophoretic profiles of white wines, obtained using this methodology, have proven to be useful for the classification of these wines by means of chemometric multivariate techniques. Principal component analysis and discriminant analysis allowed accurate classification of wine samples on the basis of their grape varietal (verdejo and airén) using the information contained in selected zones of the electropherogram. The utility of the proposed CZE methodology based on the electrochemical response of CNT‐modified electrodes appears to be promising in the field of wine industry and it is expected to be successfully extended to classification of a wider range of wines made of other grape varietals.
- 1 March 2014
- Published by Wiley in Electrophoresis
- Vol. 35 (11) , 1693-1700
Classification of Spanish white wines using their electrophoretic profiles obtained by capillary zone electrophoresis with amperometric detection
A method was developed for the simultaneous detection of eight polyphenols (t‐resveratrol, (+)‐catechin, quercetin and p‐coumaric, caffeic, sinapic, ferulic, and gallic acids) by CZE with electrochemical detection. Separation of these polyphenols was achieved within 25 min using a 200 mM borate buffer (pH 9.4) containing 10% methanol as separation electrolyte. Amperometric detection of polyphenols was carried out with a glassy carbon electrode (GCE) modified with a multiwalled carbon nanotubes (CNT) layer obtained from a dispersion of CNT in polyethylenimine. The excellent electrochemical properties of this modified electrode allowed the detection and quantification of the selected polyphenols in white wines without any pretreatment step, showing remarkable signal stability despite the presence of potential fouling substances in wine. The electrophoretic profiles of white wines, obtained using this methodology, have proven to be useful for the classification of these wines by means of chemometric multivariate techniques. Principal component analysis and discriminant analysis allowed accurate classification of wine samples on the basis of their grape varietal (verdejo and airén) using the information contained in selected zones of the electropherogram. The utility of the proposed CZE methodology based on the electrochemical response of CNT‐modified electrodes appears to be promising in the field of wine industry and it is expected to be successfully extended to classification of a wider range of wines made of other grape varietals.
- 1 February 2013
- Published by Elsevier in Food Chemistry
- Vol. 136 (3-4) , 1183-1192
Analysis of total polyphenols in wines by FIA with highly stable amperometric detection using carbon nanotube-modified electrodes
- 1 February 2013
- Published by Elsevier in Food Chemistry
- Vol. 136 (3-4) , 1183-1192
Analysis of total polyphenols in wines by FIA with highly stable amperometric detection using carbon nanotube-modified electrodes
- 10 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (2) , 275-283
CZE separation of amitrol and triazine herbicides in environmental water samples with acid‐assisted on‐column preconcentration
A simple analytical scheme for the detection and quantification of amitrol and triazine herbicides (atrazine, ametryn and atraton) and degradation product (2‐hydroxyatrazine) in environmental water samples by CZE is reported. On‐column preconcentration of analytes from untreated water samples (mineral, spring, tap and river water) is accomplished by introducing an acid plug (200 mM citrate of pH 2.0) after the sample and then proceeding with the CZE separation, using 100 mM formiate buffer of pH 3.5 as running buffer and 25.0 KV as separation voltage. UV detection at 200 nm provides LODs from 50 to 300 nM in untreated samples and they were lowered tenfold by sample preconcentration by evaporation. Calculated recoveries were typically higher than 90%. Minimal detectable concentration of the electroactive amitrol could be decreased about 20‐fold when electrochemical detection was employed by monitoring the amperometric signal at +800 mV using a carbon paste electrode (LOD of 9.6 nM, 0.81 μg/L, versus 170 nM, 14.3 μg/L, using amperometric and UV detection, respectively) in untreated water samples.
- 10 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (2) , 275-283
CZE separation of amitrol and triazine herbicides in environmental water samples with acid‐assisted on‐column preconcentration
A simple analytical scheme for the detection and quantification of amitrol and triazine herbicides (atrazine, ametryn and atraton) and degradation product (2‐hydroxyatrazine) in environmental water samples by CZE is reported. On‐column preconcentration of analytes from untreated water samples (mineral, spring, tap and river water) is accomplished by introducing an acid plug (200 mM citrate of pH 2.0) after the sample and then proceeding with the CZE separation, using 100 mM formiate buffer of pH 3.5 as running buffer and 25.0 KV as separation voltage. UV detection at 200 nm provides LODs from 50 to 300 nM in untreated samples and they were lowered tenfold by sample preconcentration by evaporation. Calculated recoveries were typically higher than 90%. Minimal detectable concentration of the electroactive amitrol could be decreased about 20‐fold when electrochemical detection was employed by monitoring the amperometric signal at +800 mV using a carbon paste electrode (LOD of 9.6 nM, 0.81 μg/L, versus 170 nM, 14.3 μg/L, using amperometric and UV detection, respectively) in untreated water samples.
- 7 December 2010
- Published by Wiley in Electroanalysis
- Vol. 23 (1) , 237-244
Application of Carbon Nanotube‐Modified Electrodes as Electrochemical Sensors for the Continuous Monitoring of 2,4‐Dichlorophenol
- 7 December 2010
- Published by Wiley in Electroanalysis
- Vol. 23 (1) , 237-244
Application of Carbon Nanotube‐Modified Electrodes as Electrochemical Sensors for the Continuous Monitoring of 2,4‐Dichlorophenol
- 11 February 2009
- Published by Wiley in Electrophoresis
- Vol. 30 (3) , 499-506
Screening and confirmatory methods for the analysis of macrocyclic lactone mycotoxins by CE with amperometric detection
A simple analytical scheme for the screening and quantification of zearalenone and its metabolites, α‐zearalenol and β‐zearalenol, is reported. Extracts from maize flour samples were collected by supercritical fluid extraction and afterwards, they were analyzed by CE with amperometric detection. This scheme allowed a rapid and reliable identification of contaminated flour samples according to the reference value established for zearalenone by directive 2005/38/EC (200 μg/kg). The sample screening method was carried out by CZE using 25 mM borate separation buffer at pH 9.2 and 25.0 kV as separation voltage, monitoring the amperometric signal at +700 mV with a carbon paste electrode. In this way, total amount of mycotoxins was determined and samples were processed in 4 min with a detection limit of 12 μg/L, enough to discriminate between positive (more than 200 μg/L total mycotoxins) and negative samples (less than 200 μg/L total mycotoxins). Positive samples were then subjected to CZE separation and quantification of each analyte was done with 50 mM borate running buffer modified with 30% methanol at pH 9.7 and 17.5 kV as separation voltage. Under these conditions, separation was achieved in 15 min with detection limits from 20 to 35 μg/L for each analyte.
- 11 February 2009
- Published by Wiley in Electrophoresis
- Vol. 30 (3) , 499-506
Screening and confirmatory methods for the analysis of macrocyclic lactone mycotoxins by CE with amperometric detection
A simple analytical scheme for the screening and quantification of zearalenone and its metabolites, α‐zearalenol and β‐zearalenol, is reported. Extracts from maize flour samples were collected by supercritical fluid extraction and afterwards, they were analyzed by CE with amperometric detection. This scheme allowed a rapid and reliable identification of contaminated flour samples according to the reference value established for zearalenone by directive 2005/38/EC (200 μg/kg). The sample screening method was carried out by CZE using 25 mM borate separation buffer at pH 9.2 and 25.0 kV as separation voltage, monitoring the amperometric signal at +700 mV with a carbon paste electrode. In this way, total amount of mycotoxins was determined and samples were processed in 4 min with a detection limit of 12 μg/L, enough to discriminate between positive (more than 200 μg/L total mycotoxins) and negative samples (less than 200 μg/L total mycotoxins). Positive samples were then subjected to CZE separation and quantification of each analyte was done with 50 mM borate running buffer modified with 30% methanol at pH 9.7 and 17.5 kV as separation voltage. Under these conditions, separation was achieved in 15 min with detection limits from 20 to 35 μg/L for each analyte.
- 1 July 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 596 (2) , 183-194
Analytical applications of glassy carbon electrodes modified with multi-wall carbon nanotubes dispersed in polyethylenimine as detectors in flow systems
- 1 July 2007
- Published by Elsevier in Analytica Chimica Acta
- Vol. 596 (2) , 183-194
Analytical applications of glassy carbon electrodes modified with multi-wall carbon nanotubes dispersed in polyethylenimine as detectors in flow systems