Evaluating In Vitro Performance of a Novel Stainless Steel Rotary System (Gentlefile) Based on Debris Extrusion and Instrumentation Time
Open Access
- 1 January 2023
- journal article
- research article
- Published by Wiley in BioMed Research International
- Vol. 2023 (1) , 9945236
Abstract
The new Gentlefile (GF) system, made of stainless steel and developed by MedicNRG in Kibbutz Afikim, Israel, claims to have advantages over traditional nickel‐titanium files. However, research has shown that nickel‐titanium files are mechanically superior due to their increased flexibility, cutting efficiency, and ability to maintain canal anatomy with less risk of procedural errors. This study compared the amount of debris extrusion and the time required for root canal instrumentation using GF versus the nickel‐titanium ProTaper Universal (PTU) system and a manual step‐back (MSB) stainless steel technique. This in vitro experimental study utilized 66 extracted human single‐canal mandibular premolars with mature apices and root curvature of less than 10 degrees. The teeth were randomly divided into three groups (n = 22) and standardized for working length before being placed in preweighed vials. Group 1 was instrumented with PTU, Group 2 with GF, and Group 3 with the MSB technique. Extruded debris was collected in the vials, dried in an incubator, and weighed using the same scale. The change in weight indicates the debris amount. Instrumentation time was recorded using a stopwatch. The normal distribution of data was assessed using the Kolmogorov‐Smirnov test. The groups were then compared regarding the amount of extruded debris and instrumentation time using the Kruskal‐Wallis test and one‐way ANOVA, followed by the Games‐Howell test, respectively (alpha = 0.05). No significant difference in apical debris extrusion was found among the three groups (P > 0.05). However, a significant difference in instrumentation time was detected between the groups (P < 0.05). MSB instrumentation took significantly longer than both the PTU (P = 0.001) and GF (P = 0.001) systems. The GF system did not demonstrate reduced apical debris extrusion or faster instrumentation time compared to PTU. MSB had the longest instrumentation time compared to the other techniques.Keywords
This publication has 29 references indexed in Scilit:
- Evaluation of Time to Fracture and Vertical Forces Applied by a Novel Gentlefile System for Root Canal Preparation in Simulated Root CanalsJournal of Endodontics, 2016
- Apical Transportation, Centering Ability, and Cleaning Effectiveness of Reciprocating Single-file System Associated with Different Glide Path TechniquesJournal of Endodontics, 2015
- Apical Extrusion of Debris Produced during Continuous Rotating and Reciprocating MotionThe Scientific World Journal, 2015
- An In Vitro Comparison of Apically Extruded Debris and Instrumentation Times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex InstrumentsJournal of Endodontics, 2014
- Assessment of Apically Extruded Debris Produced by the Self-Adjusting File SystemJournal of Endodontics, 2014
- Quantitative Assessment of Apical Debris Extrusion and Intracanal Debris in the Apical Third, Using Hand Instrumentation and Three Rotary Instrumentation SystemsJournal of Clinical and Diagnostic Research, 2014
- Comparative investigation of two rotary nickel–titanium instruments: ProTaper versus RaCe. Part 1. Shaping ability in simulated curved canalsInternational Endodontic Journal, 2004
- A comparison of weights of debris extruded apically by conventional filing and canal master techniquesJournal of Endodontics, 1991
- The effect of four preparation techniques on the amount of apically extruded debrisJournal of Endodontics, 1987
- A comparison of canal preparations in straight and curved root canalsOral Surgery, Oral Medicine, Oral Pathology, 1971