Sensor Positioning Influences the Accuracy of Knee Rom Data of an E-Rehabilitation System: A Preliminary Study with Healthy Subjects
Open Access
Abstract
E-rehabilitation is the term used to define medical rehabilitation programs that are implemented at home with the use of information and communication technologies. The aim was to test whether sensor position and the sitting position of the patient influence the accuracy of knee range of movement (ROM) data displayed by the BPMpathway e-rehabilitation system. A preliminary study was conducted in a laboratory setting with healthy adults. Knee ROM data was measured with the BPMpathway e-rehabilitation system and simultaneously with a BIOPAC twin-axis digital goniometer. The main outcome was the root mean squared error (RMSE). A 20% increase or reduction in sitting height led to a RMSE increase. A ventral shift of the BPMpathway sensor by 45° and 90° caused significant measurement errors. A vertical shift was associated with a diminution of the measurement errors. The lowest RMSE (2.4°) was achieved when the sensor was placed below the knee. The knee ROM data measured by the BPMpathway system is comparable to the data of the concurrent system, provided the instructions of the manufacturer are respected concerning the sitting position of the subject for knee exercises, and disregarding the same instructions for sensor positioning, by placing the sensor directly below the knee.Keywords
This publication has 32 references indexed in Scilit:
- Future projections of total hip and knee arthroplasty in the UK: results from the UK Clinical Practice Research DatalinkOsteoarthritis and Cartilage, 2015
- Clinical Evaluation of a Mobile Sensor-Based Gait Analysis Method for Outcome Measurement after Knee ArthroplastySensors, 2014
- Comparison of Effects of Supervised Physiotherapy and a Standardized Home Program on Functional Status in Patients with Total Knee Arthroplasty: A Prospective StudyJournal of Physical Therapy Science, 2014
- Reliability of a smartphone-based goniometer for knee joint goniometryInternational Journal of Rehabilitation Research, 2013
- Physiotherapy Exercise After Fast-Track Total Hip and Knee Arthroplasty: Time for Reconsideration?Archives of Physical Medicine and Rehabilitation, 2012
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedInternational Journal of Nursing Studies, 2011
- International survey of primary and revision total knee replacementInternational Orthopaedics, 2011
- Ambulatory measurement of 3D knee joint angleJournal of Biomechanics, 2008
- The operation of the century: total hip replacementThe Lancet, 2007
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studiesThe Lancet, 2007