Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlos Joan Marques has a total of 75 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Assessment of dynamic knee angle deviations in the frontal plane in physiotherapy clinical practice: intra- and inter-rater reliability of an application and agreement with two AI-models

    by Lukas Janisch, Lilo-Marie Maack, Dominik Fohrmann, Carlos J. Marques

    Background: Functional leg axis deviations, particularly dynamic knee valgus (DKV), are considered key risk factors for lower-extremity injuries. In physiotherapy practice there are no standardized tools to quantitatively assess functional leg axis deviations within a treatment session. While application-based 2D analyses offer accessible options, the agreement between manual and automated, AI-based Human Pose Estimation (HPE) methods remains underexplored. Here, the aims were to investigate the intra- and inter-rater reliability of a manual application-based method (PhysioMaster®); to quantify the agreement between two AI-based HPE models (OpenPose, BlazePose); and to explore which functional test, Single-Leg Squat (SLS), Single-Leg Hop for Distance (SLH), or Single-Leg Landing (SLL), elicits the most pronounced leg axis deviations. Methods: Sixteen healthy adults (8 females) performed three standardized single-leg tasks (SLS, SLH, SLL) with each leg. Knee angles in the frontal plane were measured from monocular video images using the PhysioMaster® application (two raters × two ratings) and compared with automated 2D analyses using OpenPose and BlazePose. Reliability and agreement were evaluated using Intraclass Correlation Coefficients, Lin’s Concordance Correlation Coefficient (CCC), and Bland–Altman analyses. Linear Mixed Model (LMM) analyses were carried out to explore which functional task would be the most effective. Results: The PhysioMaster® application showed excellent intra- and inter-rater reliability across all tests (ICC ≥ 0.95). OpenPose demonstrated excellent agreement with manual application-based measurements (CCC = 0.95; Bias = 0.87°; LoA = –4.32° to 6.05°), while BlazePose achieved good agreement (CCC = 0.89; Bias = –0.67°; LoA = –8.76° to 7.42°). LMM analyses revealed that all three tasks significantly evoked knee angle deviations. The SLL evoked the largest valgus angles (Estimate = –8.29°, p < .001), while the SLS elicited the highest varus angles (Estimate = 7.92°, p < .001). Conclusion: Both, manual application-based and AI-based 2D methods, provided reliable and largely consistent assessments of knee valgus angles in the frontal plane during functional testing. OpenPose achieved the best agreement with manual application-based reference values, and the SLL was the most suitable task for detecting DKV. While the results support the integration of manual application-based and AI-assisted posture analysis into clinical physiotherapy, further research on concurrent validity of all three methods used against 3D motion capture is needed.

  • Open Access

    Satisfied with the worst health outcomes or unsatisfied with the best: explaining the divergence between good patient-reported outcomes and low satisfaction and vice versa among knee arthroplasty patients – a retrospective cohort study

    by Lukas Schöner, Viktoria Steinbeck, Reinhard Busse, Carlos J. Marques

    Objectives: Total knee arthroplasty (TKA) is an effective treatment for patients with end-stage knee osteoarthritis but some patients exhibit a discrepancy between patient-reported outcomes (PROs) and patient satisfaction (PS). This study aims to identify predictors for patients reporting unfavorable PROs but high PS and vice versa. Materials and methods: This retrospective cohort study categorized patients from nine German hospitals into four groups based on (i) whether they achieved a minimal clinically important difference (MCID) in knee functionality, measured with a joint-specific PRO from admission to 12-month post-surgery; and (ii) whether they were satisfied at 12 months post-surgery. The groups were (A) Satisfied Achievers (satisfied, MCID reached), (B) Dissatisfied Achievers (not satisfied, MCID reached), (C) Satisfied Non-Achievers (satisfied, MCID not reached) and (D) Dissatisfied Non-Achievers (not satisfied, MCID not reached). Exploratory analyses were performed to understand differences between the four groups using chi-squared tests and ANOVA. Multinomial logistic regression models were conducted to identify predictors for the allocation of patients in groups. Results: A total of 1546 knee arthroplasty patients with a mean age of 65.9 years, 54.1% female, were included. 1146 (74.1%) patients were Satisfied Achievers, 131 (8.5%) were Dissatisfied Achievers, 141 (9.1%) were Satisfied Non-Achievers, and 128 (8.3%) Dissatisfied Non-Achievers. The results showed that higher improvements in health-related quality of life, pain and fatigue symptoms significantly decreased the likelihood of being a Dissatisfied Achiever and a Satisfied Non-Achiever. Comorbidities of blood circulation, chronic back pain or diabetes increased the likelihood of being a Dissatisfied Achiever, while depression decreased the likelihood of being a Satisfied Non-Achiever. Conclusion: Addressing individual health concerns, e.g. through expectation management, and assessing alternative treatment options might improve satisfaction in line with functional improvements. A closer evaluation at which physical impairment level surgery is beneficial could help to improve the care of Satisfied Non-Achievers.


  • Open Access

    What is the association between gender and self-perceived health status when controlling for disease-specific conditions? A retrospective data analysis of pre- and post-operative EQ-5D-5L differences in total hip and knee arthroplasty

    by Anja Y. Bischof, Viktoria Steinbeck, David Kuklinski, Carlos J. Marques, Karina Bohlen, Karl C. Westphal, Frank Lampe, Alexander Geissler

    Background: The self-perceived health status of patients undergoing total hip and knee arthroplasty (THA and TKA) might differ post-operatively due to gender, age, or comorbidities. Patient-reported outcome measures (PROMs) such as the EQ-5D-5L measure the self-perceived health status. This study investigates whether the index score of the EQ-5D-5L is a valid tool for interpreting gender differences in outcomes for patients undergoing THA and TKA. Methods: Routine and PROM-data of elective primary THA or TKA patients in two German hospitals between 2016 and 2018 were analyzed. Univariate analysis with Pearson’s chi-square was conducted to identify control variables for gender. To quantify the association between gender and the EQ-5D-5L dimensions, a cumulative odds ordinal logistic regression with proportional odds was conducted. Results: Two thousand three hundred sixty-eight​​ THA patients (m = 978; f = 1390) and 1629 TKA patients (m = 715; f = 914) were considered. The regression analysis of the individual EQ-5D-5L dimensions showed that female gender was significantly associated with better self-care (THA and TKA) and better post-operative mobility (THA). In contrast, male gender was significantly associated with less pain/discomfort (TKA) and less anxiety/depression (THA) pre-surgery and 3-months post-surgery. Conclusion: Our results confirmed that the self-perceived health status improved after surgery. However, due to the different associations of gender to the individual dimensions of the EQ-5D-5L, the weighted index score clouds the comparability between patients with different gender undergoing THA or TKA. Therefore, we argue to use the individual five dimensions for health status analysis, to reveal relevant additional information.


  • Thresholds for meaningful improvement in WOMAC scores need to be adjusted to patient characteristics after hip and knee replacement

    by David Kuklinski, Carlos J. Marques, Karina Bohlen, Karl C. Westphal, Frank Lampe, Alexander Geissler


  • Open Access

    Erratum to: Cervical Single-Level Pincer Stenosis Causing Myelopathy: A Technical Note and Medium-term Results of a One-Session Microsurgical 360-Degree Treatment

    by Luca Papavero, Markus Pietrek, Carlos J. Marques, Gregor Schmeiser

    The authors have informed the Publisher about a change in the presentation of the third authors' name. The DOI of the original article is: https://doi.org/10.1055/s-0041-1723811 (published efirst on October 11, 2021). 1. The author name “Carlos José Marques” should read as “Carlos J. Marques”. 2. ORCID ID of Dr. Carlos J. Marques has been added. The ORCID is 0000-0003-3216-6382. The details have been corrected in the author field given above. Publication Date: 06 December 2021 (online) © 2021. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    Cervical Single-Level Pincer Stenosis Causing Myelopathy: A Technical Note and Medium-term Results of a One-Session Microsurgical 360-Degree Treatment

    by Luca Papavero, Markus Pietrek, Carlos Joan Marques, Gregor Schmeiser

    Background and Study Aims Single-level circumferential or pincer stenosis (PS) affects few patients with degenerative cervical myelopathy (DCM). The surgical technique and medium-term results of a one-session microsurgical 360-degree (m360°) procedure are presented. Patients Between 2013 and 2018, the data of 23 patients were prospectively collected out of 371 patients with DCM. The m360° procedure comprised a microsurgical anterior cervical decompression and fusion (ACDF), with additional plate fixation, followed by flipping the patient and performing a microsurgical posterior bilateral decompression via a unilateral approach in crossover technique. Results The mean age of the patients was 72 years (range: 50–84); 17 patients were males. The mean follow-up time was 12 months (range: 6–31). The patients filled in the patient-derived modified Japanese Orthopaedic Association (P-mJOA) questionnaire on average 53 months after surgery. One patient received a two-level ACDF. Lesions were mostly (92%) located at the C3/C4 (8/24), C4/C5 (7/24), and C5/C6 (7/24) levels. Functional X-rays showed segmental instability in 10 of 23 patients (44%). All preoperative T2-weighted magnetic resonance imaging (MRI) showed an intramedullary hyperintensity. The median preoperative mJOA score was 13 (range 3), and it improved to 16 (range 3) postoperatively. The mean improvement rate in the mJOA score was 73%. When available, postoperative MRI confirmed good circumferential decompression with persistent intramedullary hyperintensity. There were two complications: a long-lasting radicular paresthesia at C6 and a transient C5 palsy. No revision surgery was required. Conclusion The one-session m360° procedure was found to be a safe surgical procedure for the treatment of PS, and the medium-term clinical outcome was satisfactory.


  • Open Access

    The prevalence of redundant nerve roots in patients with lumbar spinal stenosis is body position dependent: a retrospective observational study with repeated measures design in an upright MRI scanner

    by Luca Papavero, Stella Ebert, Carlos J. Marques

    Purpose Redundant nerve roots (RNRs) are a negative prognostic factor in patients with central lumbar spinal stenosis (LSS). Forty percent of candidates for surgical decompression show RNRs (RNR+) on preoperative conventional magnetic resonance imaging (MRI). We investigated the prevalence of RNRs in three functional postures (standing, neutral sitting and flexed sitting) with an upright MRI (upMRI). Methods A retrospective observational study with a repeated measures design. Thirty surgical candidates underwent upMRI. Sagittal and axial T2-weighted images of the three functional postures were evaluated. The segmental length of the lumbar spine (sLLS), the lordotic angle (LA) and the dural cross-sectional area (DCSA) were measured in each body position. Generalized linear mixed models were carried out. The 0.05 level of probability was set as the criterion for statistical significance. Results The prevalence of RNRs decreased from 80% during standing to 16.7% during flexed sitting (p < 0.001). The sLLS increased significantly from standing to neutral sitting in both RNR groups (p < 0.001). The increase from neutral sitting to flexed sitting was only significant (p < 0.001) for the group without RNRs (RNR−). The LA decreased significantly for both RNR groups from standing to flexed sitting (p < 0.001). The DSCA increased significantly in the RNR− group (p < 0.001) but not in the RNR+ group (p = 0.9). Conclusion The prevalence of RNRs is body position dependent. Increases in DCSA play a determinant role in resolving RNRs.


  • Open Access

    Sensor Positioning Influences the Accuracy of Knee Rom Data of an E-Rehabilitation System: A Preliminary Study with Healthy Subjects

    by Carlos J. Marques, Christian Bauer, Dafne Grimaldo, Steffen Tabeling, Timo Weber, Alexander Ehlert, Alexandre H. Mendes, Juergen Lorenz, Frank Lampe

    E-rehabilitation is the term used to define medical rehabilitation programs that are implemented at home with the use of information and communication technologies. The aim was to test whether sensor position and the sitting position of the patient influence the accuracy of knee range of movement (ROM) data displayed by the BPMpathway e-rehabilitation system. A preliminary study was conducted in a laboratory setting with healthy adults. Knee ROM data was measured with the BPMpathway e-rehabilitation system and simultaneously with a BIOPAC twin-axis digital goniometer. The main outcome was the root mean squared error (RMSE). A 20% increase or reduction in sitting height led to a RMSE increase. A ventral shift of the BPMpathway sensor by 45° and 90° caused significant measurement errors. A vertical shift was associated with a diminution of the measurement errors. The lowest RMSE (2.4°) was achieved when the sensor was placed below the knee. The knee ROM data measured by the BPMpathway system is comparable to the data of the concurrent system, provided the instructions of the manufacturer are respected concerning the sitting position of the subject for knee exercises, and disregarding the same instructions for sensor positioning, by placing the sensor directly below the knee.