Access resistance of stimulation electrodes as a function of electrode proximity to the retina
Authors:
- 4 December 2014
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 12 (1) , 016006
Abstract
Objective. Epiretinal prostheses seek to effectively stimulate the retina by positioning electrode arrays close to its surface so current pulses generate narrow retinal electric fields. Our objective was to evaluate the use of the electrical impedance of insulated platinum electrodes as a measure of the proximity of insulated platinum electrodes to the inner surface of the retina. Approach. We examined the impedance of platinum disk electrodes, 0.25 mm in diameter, insulated with two widths (0.8 and 1.6 mm outer diameter) of transparent fluoropolymer in a rabbit retinal eyecup preparation. Optical coherence tomography measured the electrode's proximity to the retinal surface which was correlated with changes in the voltage waveform at the electrode. Electrode impedance changes during retinal deformation were also studied. Main results. When the 1.6 mm diameter insulated electrodes advanced towards the retinal surface from 1000 mu m, their voltage step at current pulse onset increased, reflecting an access resistance increase of 3880 +/- 630 Omega, with the 50% midpoint averaging 30 mu m, while thin 0.8 mm insulated electrode advancement showed an access resistance increase 50% midpoint averaging 16 mu m. Using impedance spectroscopy, electrode-retina proximity differences were seen in the 1.6 mm insulated electrode impedance modulus between 1 and 100 kHz and the waveform phase angle at 0.3-10 kHz, while thin 0.8 mm insulated electrode advancement produced smaller impedance modulus changes with retinal proximity between 3 and 100 kHz. These impedance changes with retinal proximity may reflect different sized zones of eye wall being coupled in series with the insulated platinum electrode. Significance. The proximity of stimulus electrodes to neural tissue in fluid-filled spaces can be estimated from access resistance changes in the stimulus pulse waveform. Because many prosthetic devices allow back telemetry communication of the stimulus electrode waveform, it is possible these series resistance increases observed with retinal proximity could be used as a metric of stimulus electrode placement.Keywords
Funding Information
- U.S. Food and Drug Administration (Critical Path Grant)
This publication has 29 references indexed in Scilit:
- Post-implantation impedance spectroscopy of subretinal micro-electrode arrays, OCT imaging and numerical simulation: towards a more precise neuroprosthesis monitoring toolJournal of Neural Engineering, 2013
- Factors Affecting Perceptual Threshold in Argus II Retinal Prosthesis SubjectsTranslational Vision Science & Technology, 2013
- Interim Results from the International Trial of Second Sight's Visual ProsthesisOphthalmology, 2012
- Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implantsJournal of Neural Engineering, 2011
- Imaging of electrode position in relation to electrode functioning after cochlear implantationEuropean Archives of Oto-Rhino-Laryngology, 2009
- Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,Journal of Rehabilitation Research and Development, 2008
- Role of Electrode Placement as a Contributor to Variability in Cochlear Implant OutcomesOtology & Neurotology, 2008
- Factors Affecting Perceptual Thresholds in Epiretinal ProsthesesInvestigative Ophthalmology & Visual Science, 2008
- Foveal Fine Structure in Retinopathy of Prematurity: An Adaptive Optics Fourier Domain Optical Coherence Tomography StudyInvestigative Ophthalmology & Visual Science, 2008
- Impedance-based retinal contact imaging as an aid for the placement of high resolution epiretinal prosthesesJournal of Neural Engineering, 2007