Ethan David Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ethan David Cohen has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
Peter Sterling
Department of Anatomy, University of Pennsylvania Medical School, Philadelphia, PA 19104‐6058, USA
6 shared publications- Colin J. Barnstable
Department of Neuroscience, Penn State College of Medicine, Hershey, PA 17033, USA
4 shared publications Ji-Ye Wei
Department of Ophthalmology and Visual Science, Yale University School of Medicine, 330 Cedar Street, P.O. Box 208061, New Haven, CT 06520-8061, USA
4 shared publicationsAnant Agrawal
Division of Biomedical Physics, Office of Science and Engineering Labs, Center for Devices and Radiological Health, Food and Drug Administration, White Oak Federal Research Labs, Silver Spring, Maryland, United States
3 shared publications- Andras Jakab
Center for MR Research, University Children’s Hospital Zurich
3 shared publications Esther Akinnagbe
Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland, 20993, United States of America
3 shared publications
Latest Publications
- Open Access
A Real K3 Automorphism with Most of Its Entropy in the Real Part
This article describes an example of a real projective K3 surface admitting a real automorphism $f$ satisfying $h_{top}(f, X(\mathbb{C})) < 2 h_{top}(f, X(\mathbb{R}))$. The example presented is a $(2,2,2)$-surface in $\mathbb{P}^1 \times \mathbb{P}^1 \times \mathbb{P}^1$ given by the vanishing set of $(1 + x^2)(1 + y^2)(1 + z^2) + 10xyz - 2$, first considered by McMullen. Along the way, we develop an ad hoc shadowing lemma for $C^2$ (real) surface diffeomorphisms, and apply it to estimate the location of a periodic point in $X(\mathbb{R})$. This result uses the GNU MPFR arbitrary precision arithmetic library in C and the Flipper computer program.Open AccessA Real K3 Automorphism with Most of Its Entropy in the Real Part
This article describes an example of a real projective K3 surface admitting a real automorphism $f$ satisfying $h_{top}(f, X(\mathbb{C})) < 2 h_{top}(f, X(\mathbb{R}))$. The example presented is a $(2,2,2)$-surface in $\mathbb{P}^1 \times \mathbb{P}^1 \times \mathbb{P}^1$ given by the vanishing set of $(1 + x^2)(1 + y^2)(1 + z^2) + 10xyz - 2$, first considered by McMullen. Along the way, we develop an ad hoc shadowing lemma for $C^2$ (real) surface diffeomorphisms, and apply it to estimate the location of a periodic point in $X(\mathbb{R})$. This result uses the GNU MPFR arbitrary precision arithmetic library in C and the Flipper computer program. - 19 February 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (1)
Guest editorial: Materials and technologies for bioimaging and biosensing
- 19 February 2025
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 12 (1)
Guest editorial: Materials and technologies for bioimaging and biosensing
- Open Access
- 22 January 2024
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 18, 1290829
Effect of epiretinal electrical stimulation on the glial cells in a rabbit retinal eyecup model
Introduction: We examined how pulse train electrical stimulation of the inner surface of the rabbit retina effected the resident glial cells. We used a rabbit retinal eyecup preparation model, transparent stimulus electrodes, and optical coherence tomography (OCT). The endfeet of Müller glia processes line the inner limiting membrane (ILM).Methods: To examine how epiretinal electrode stimulation affected the Müller glia, we labeled them post stimulation using antibodies against soluble glutamine synthetase (GS). After 5 min 50 Hz pulse train stimulation 30 μm from the surface, the retina was fixed, immunostained for Müller glia, and examined using confocal microscopic reconstruction. Stimulus pulse charge densities between 133–749 μC/cm2/ph were examined.Results: High charge density stimulation (442–749 μC/cm2/ph) caused significant losses in the GS immunofluorescence of the Müller glia endfeet under the electrode. This loss of immunofluorescence was correlated with stimuli causing ILM detachment when measured using OCT. Müller cells show potassium conductances at rest that are blocked by barium ions. Using 30 msec 20 μA stimulus current pulses across the eyecup, the change in transretinal resistance was examined by adding barium to the Ringer. Barium caused little change in the transretinal resistance, suggesting under low charge density stimulus pulse conditions, the Müller cell radial conductance pathway for these stimulus currents was small. To examine how epiretinal electrode stimulation affected the microglia, we used lectin staining 0–4 h post stimulation. After stimulation at high charge densities 749 μC/cm2/ph, the microglia under the electrode appeared rounded, while the local microglia outside the electrode responded to the stimulated retina by process orientation inwards in a ring by 30 min post stimulation.Discussion: Our study of glial cells in a rabbit eyecup model using transparent electrode imaging suggests that epiretinal electrical stimulation at high pulse charge densities, can injure the Müller and microglia cells lining the inner retinal surface in addition to ganglion cells.
- 22 January 2024
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 18, 1290829
Open AccessEffect of epiretinal electrical stimulation on the glial cells in a rabbit retinal eyecup model
Introduction: We examined how pulse train electrical stimulation of the inner surface of the rabbit retina effected the resident glial cells. We used a rabbit retinal eyecup preparation model, transparent stimulus electrodes, and optical coherence tomography (OCT). The endfeet of Müller glia processes line the inner limiting membrane (ILM).Methods: To examine how epiretinal electrode stimulation affected the Müller glia, we labeled them post stimulation using antibodies against soluble glutamine synthetase (GS). After 5 min 50 Hz pulse train stimulation 30 μm from the surface, the retina was fixed, immunostained for Müller glia, and examined using confocal microscopic reconstruction. Stimulus pulse charge densities between 133–749 μC/cm2/ph were examined.Results: High charge density stimulation (442–749 μC/cm2/ph) caused significant losses in the GS immunofluorescence of the Müller glia endfeet under the electrode. This loss of immunofluorescence was correlated with stimuli causing ILM detachment when measured using OCT. Müller cells show potassium conductances at rest that are blocked by barium ions. Using 30 msec 20 μA stimulus current pulses across the eyecup, the change in transretinal resistance was examined by adding barium to the Ringer. Barium caused little change in the transretinal resistance, suggesting under low charge density stimulus pulse conditions, the Müller cell radial conductance pathway for these stimulus currents was small. To examine how epiretinal electrode stimulation affected the microglia, we used lectin staining 0–4 h post stimulation. After stimulation at high charge densities 749 μC/cm2/ph, the microglia under the electrode appeared rounded, while the local microglia outside the electrode responded to the stimulated retina by process orientation inwards in a ring by 30 min post stimulation.Discussion: Our study of glial cells in a rabbit eyecup model using transparent electrode imaging suggests that epiretinal electrical stimulation at high pulse charge densities, can injure the Müller and microglia cells lining the inner retinal surface in addition to ganglion cells.
- 8 January 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (2) , 025003
The microglia response to electrical overstimulation of the retina imaged under a transparent stimulus electrode
Objective. We investigated using the morphological response of retinal microglia as indicators of tissue damage from electrical overstimulation by imaging them through an optically transparent stimulus electrode. Approach. To track the microglia, we used a transgenic mouse where the microglia expressed a water soluble green fluorescent protein. The clear stimulus electrode was placed epiretinally on the inner limiting membrane and the microglia layers were imaged using time-lapse confocal microscopy. We examined how the microglia responded both temporally and spatially to local overstimulation of the retinal tissue. Using confocal microscope vertical image stacks, the microglia under the electrode were imaged at 2.5 min intervals. The retina was overstimulated for a 5 min period using 1 ms 749 μC cm−2 ph−1 biphasic current pulses and changes in the microglia morphology were followed for 1 h post stimulation. After the imaging period, a label for cellular damage was applied to the retina. Main results. The microglia response to overstimulation depended on their spatial location relative to the electrode lumen and could result in three different morphological responses. Some microglia were severely injured and became a series of immotile ball-like fluorescent processes. Other microglia survived, and reacted rapidly to the injury by extending filopodia oriented toward the damage zone. This response was seen in inner retinal microglia outside the stimulus electrode edge. A third effect, seen with the deeper outer microglia under the electrode, was a fading of their fluorescent image which appeared to be due to optical scatter caused by overstimulation-induced retinal edema. Significance. The microglial morphological responses to electrical overstimulation injury occur rapidly and can show both direct and indirect effects of the stimulus electrode injury. The microglia injury pattern closely follows models of the electric field distribution under thinly insulated disc electrodes.
- 8 January 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (2) , 025003
The microglia response to electrical overstimulation of the retina imaged under a transparent stimulus electrode
Objective. We investigated using the morphological response of retinal microglia as indicators of tissue damage from electrical overstimulation by imaging them through an optically transparent stimulus electrode. Approach. To track the microglia, we used a transgenic mouse where the microglia expressed a water soluble green fluorescent protein. The clear stimulus electrode was placed epiretinally on the inner limiting membrane and the microglia layers were imaged using time-lapse confocal microscopy. We examined how the microglia responded both temporally and spatially to local overstimulation of the retinal tissue. Using confocal microscope vertical image stacks, the microglia under the electrode were imaged at 2.5 min intervals. The retina was overstimulated for a 5 min period using 1 ms 749 μC cm−2 ph−1 biphasic current pulses and changes in the microglia morphology were followed for 1 h post stimulation. After the imaging period, a label for cellular damage was applied to the retina. Main results. The microglia response to overstimulation depended on their spatial location relative to the electrode lumen and could result in three different morphological responses. Some microglia were severely injured and became a series of immotile ball-like fluorescent processes. Other microglia survived, and reacted rapidly to the injury by extending filopodia oriented toward the damage zone. This response was seen in inner retinal microglia outside the stimulus electrode edge. A third effect, seen with the deeper outer microglia under the electrode, was a fading of their fluorescent image which appeared to be due to optical scatter caused by overstimulation-induced retinal edema. Significance. The microglial morphological responses to electrical overstimulation injury occur rapidly and can show both direct and indirect effects of the stimulus electrode injury. The microglia injury pattern closely follows models of the electric field distribution under thinly insulated disc electrodes.
- Top Cited PapersOpen Access
- 22 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124126
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.
- 22 April 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (4) , e0124126
Top Cited PapersOpen AccessMIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Computational modeling and simulations are increasingly being used to complement experimental testing for analysis of safety and efficacy of medical devices. Multiple voxel- and surface-based whole- and partial-body models have been proposed in the literature, typically with spatial resolution in the range of 1–2 mm and with 10–50 different tissue types resolved. We have developed a multimodal imaging-based detailed anatomical model of the human head and neck, named “MIDA”. The model was obtained by integrating three different magnetic resonance imaging (MRI) modalities, the parameters of which were tailored to enhance the signals of specific tissues: i) structural T1- and T2-weighted MRIs; a specific heavily T2-weighted MRI slab with high nerve contrast optimized to enhance the structures of the ear and eye; ii) magnetic resonance angiography (MRA) data to image the vasculature, and iii) diffusion tensor imaging (DTI) to obtain information on anisotropy and fiber orientation. The unique multimodal high-resolution approach allowed resolving 153 structures, including several distinct muscles, bones and skull layers, arteries and veins, nerves, as well as salivary glands. The model offers also a detailed characterization of eyes, ears, and deep brain structures. A special automatic atlas-based segmentation procedure was adopted to include a detailed map of the nuclei of the thalamus and midbrain into the head model. The suitability of the model to simulations involving different numerical methods, discretization approaches, as well as DTI-based tensorial electrical conductivity, was examined in a case-study, in which the electric field was generated by transcranial alternating current stimulation. The voxel- and the surface-based versions of the models are freely available to the scientific community.
- Open Access
- 18 December 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (1) , 587-597
The Use of Time-Lapse Optical Coherence Tomography to Image the Effects of Microapplied Toxins on the Retina
We developed a novel technique for accelerated drug screening and retinotoxin characterization using time-lapse optical coherence tomography (OCT) and a drug microapplication device. Using an ex vivo rabbit eyecup preparation, we studied retinotoxin effects in real-time by microperfusing small retinal areas under a transparent fluoropolymer tube. Known retinotoxic agents were applied to the retina for 5-minute periods, while changes in retinal structure, thickness, and reflectance were monitored with OCT. The OCT images of two agents with dissimilar mechanisms, cyanide and kainic acid, were compared to their structural changes seen histologically. We found the actions of retinotoxic agents tested could be classified broadly into two distinct types: (1) agents that induce neuronal depolarization, such as kainic acid, causing increases in OCT reflectivity or thickness of the inner plexiform and nuclear layers, and decreased reflectivity of the outer retina; and (2) agents that disrupt mitochondrial function, such as cyanide, causing outer retinal structural changes as evidenced by a reduction in the OCT reflectivity of the photoreceptor outer segment and pigment epithelium layers. Retinotoxin-induced changes in retinal layer reflectivity and thickness under the microperfusion tube in OCT images closely matched the histological evidence of retinal injury. Time-lapse OCT imaging of the microperfused local retina has the potential to accelerate drug retinotoxicological screening and expand the use of OCT as an evaluation tool for preclinical animal testing.
- 18 December 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (1) , 587-597
Open AccessThe Use of Time-Lapse Optical Coherence Tomography to Image the Effects of Microapplied Toxins on the Retina
We developed a novel technique for accelerated drug screening and retinotoxin characterization using time-lapse optical coherence tomography (OCT) and a drug microapplication device. Using an ex vivo rabbit eyecup preparation, we studied retinotoxin effects in real-time by microperfusing small retinal areas under a transparent fluoropolymer tube. Known retinotoxic agents were applied to the retina for 5-minute periods, while changes in retinal structure, thickness, and reflectance were monitored with OCT. The OCT images of two agents with dissimilar mechanisms, cyanide and kainic acid, were compared to their structural changes seen histologically. We found the actions of retinotoxic agents tested could be classified broadly into two distinct types: (1) agents that induce neuronal depolarization, such as kainic acid, causing increases in OCT reflectivity or thickness of the inner plexiform and nuclear layers, and decreased reflectivity of the outer retina; and (2) agents that disrupt mitochondrial function, such as cyanide, causing outer retinal structural changes as evidenced by a reduction in the OCT reflectivity of the photoreceptor outer segment and pigment epithelium layers. Retinotoxin-induced changes in retinal layer reflectivity and thickness under the microperfusion tube in OCT images closely matched the histological evidence of retinal injury. Time-lapse OCT imaging of the microperfused local retina has the potential to accelerate drug retinotoxicological screening and expand the use of OCT as an evaluation tool for preclinical animal testing.
- 4 December 2014
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 12 (1) , 016006
Access resistance of stimulation electrodes as a function of electrode proximity to the retina
Objective. Epiretinal prostheses seek to effectively stimulate the retina by positioning electrode arrays close to its surface so current pulses generate narrow retinal electric fields. Our objective was to evaluate the use of the electrical impedance of insulated platinum electrodes as a measure of the proximity of insulated platinum electrodes to the inner surface of the retina. Approach. We examined the impedance of platinum disk electrodes, 0.25 mm in diameter, insulated with two widths (0.8 and 1.6 mm outer diameter) of transparent fluoropolymer in a rabbit retinal eyecup preparation. Optical coherence tomography measured the electrode's proximity to the retinal surface which was correlated with changes in the voltage waveform at the electrode. Electrode impedance changes during retinal deformation were also studied. Main results. When the 1.6 mm diameter insulated electrodes advanced towards the retinal surface from 1000 mu m, their voltage step at current pulse onset increased, reflecting an access resistance increase of 3880 +/- 630 Omega, with the 50% midpoint averaging 30 mu m, while thin 0.8 mm insulated electrode advancement showed an access resistance increase 50% midpoint averaging 16 mu m. Using impedance spectroscopy, electrode-retina proximity differences were seen in the 1.6 mm insulated electrode impedance modulus between 1 and 100 kHz and the waveform phase angle at 0.3-10 kHz, while thin 0.8 mm insulated electrode advancement produced smaller impedance modulus changes with retinal proximity between 3 and 100 kHz. These impedance changes with retinal proximity may reflect different sized zones of eye wall being coupled in series with the insulated platinum electrode. Significance. The proximity of stimulus electrodes to neural tissue in fluid-filled spaces can be estimated from access resistance changes in the stimulus pulse waveform. Because many prosthetic devices allow back telemetry communication of the stimulus electrode waveform, it is possible these series resistance increases observed with retinal proximity could be used as a metric of stimulus electrode placement.
- 4 December 2014
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 12 (1) , 016006
Access resistance of stimulation electrodes as a function of electrode proximity to the retina
Objective. Epiretinal prostheses seek to effectively stimulate the retina by positioning electrode arrays close to its surface so current pulses generate narrow retinal electric fields. Our objective was to evaluate the use of the electrical impedance of insulated platinum electrodes as a measure of the proximity of insulated platinum electrodes to the inner surface of the retina. Approach. We examined the impedance of platinum disk electrodes, 0.25 mm in diameter, insulated with two widths (0.8 and 1.6 mm outer diameter) of transparent fluoropolymer in a rabbit retinal eyecup preparation. Optical coherence tomography measured the electrode's proximity to the retinal surface which was correlated with changes in the voltage waveform at the electrode. Electrode impedance changes during retinal deformation were also studied. Main results. When the 1.6 mm diameter insulated electrodes advanced towards the retinal surface from 1000 mu m, their voltage step at current pulse onset increased, reflecting an access resistance increase of 3880 +/- 630 Omega, with the 50% midpoint averaging 30 mu m, while thin 0.8 mm insulated electrode advancement showed an access resistance increase 50% midpoint averaging 16 mu m. Using impedance spectroscopy, electrode-retina proximity differences were seen in the 1.6 mm insulated electrode impedance modulus between 1 and 100 kHz and the waveform phase angle at 0.3-10 kHz, while thin 0.8 mm insulated electrode advancement produced smaller impedance modulus changes with retinal proximity between 3 and 100 kHz. These impedance changes with retinal proximity may reflect different sized zones of eye wall being coupled in series with the insulated platinum electrode. Significance. The proximity of stimulus electrodes to neural tissue in fluid-filled spaces can be estimated from access resistance changes in the stimulus pulse waveform. Because many prosthetic devices allow back telemetry communication of the stimulus electrode waveform, it is possible these series resistance increases observed with retinal proximity could be used as a metric of stimulus electrode placement.
- Open Access
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 6258-6261
A computational model for bipolar deep brain stimulation of the subthalamic nucleus
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has been shown to reduce some of the symptoms of advanced, levodopa-responsive Parkinson's disease that are not adequately controlled with medication. However, the precise mechanism of the therapeutic action of DBS is still unclear. Stimulation-induced side effects are not uncommon and require electrical “dose” adjustments. Quantitative methods are needed to fully characterize the electric field in the deep brain region that surrounds the electrodes in order to help with adjustments and maximize the efficacy of the device. Herein we report a magnetic resonance imaging (MRI)-based head model proposed for analysis of fields generated by deep brain stimulation (DBS). The model was derived from multimodal image data at 0.5mm isotropic spatial resolution and distinguishes 142 anatomical structures, including the basal ganglia and 38 nuclei of the thalamus. Six bipolar electrode configurations (1-2, 1-3, 1-4, 2-3, 2-4, 3-4) were modeled in order to assess the effects of the inter-electrode distance of the electric field. Increasing the distance between the electrodes results in an attenuated stimulation, with up to 25% reduction in electric field amplitude delivered (2-3 vs. 1-4). The map of the deep brain structures provided a highly precise anatomical detail which is useful for the quantitative assessment of current spread around the electrode and a better evaluation of the stimulation setting for the treatment optimization.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 6258-6261
Open AccessA computational model for bipolar deep brain stimulation of the subthalamic nucleus
Deep brain stimulation (DBS) of the subthalamic nucleus (STN) has been shown to reduce some of the symptoms of advanced, levodopa-responsive Parkinson's disease that are not adequately controlled with medication. However, the precise mechanism of the therapeutic action of DBS is still unclear. Stimulation-induced side effects are not uncommon and require electrical “dose” adjustments. Quantitative methods are needed to fully characterize the electric field in the deep brain region that surrounds the electrodes in order to help with adjustments and maximize the efficacy of the device. Herein we report a magnetic resonance imaging (MRI)-based head model proposed for analysis of fields generated by deep brain stimulation (DBS). The model was derived from multimodal image data at 0.5mm isotropic spatial resolution and distinguishes 142 anatomical structures, including the basal ganglia and 38 nuclei of the thalamus. Six bipolar electrode configurations (1-2, 1-3, 1-4, 2-3, 2-4, 3-4) were modeled in order to assess the effects of the inter-electrode distance of the electric field. Increasing the distance between the electrodes results in an attenuated stimulation, with up to 25% reduction in electric field amplitude delivered (2-3 vs. 1-4). The map of the deep brain structures provided a highly precise anatomical detail which is useful for the quantitative assessment of current spread around the electrode and a better evaluation of the stimulation setting for the treatment optimization.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational platform combining detailed and precise functionalized anatomical phantoms with EM-Neuron interaction modeling
A computational framework including functionalized anatomical phantoms able to simulate electromagnetic (EM)-neuron interactions in complex tissue-structure environments was developed. The anatomic head model distinguishes a large number of structures, particularly in regions relevant to EM-neuron interactions (i.e., ear, eye, deep brain structures). Multimodal Magnetic Resonance (MR) images were acquired together with Diffusion Tensor Imaging (DTI) data to guide neuron model placement and inform about tissue anisotropy. A dedicated EM solver was implemented and coupled with dynamic models of neuronal activity. The topologically conforming, non-self-intersecting, high-element-quality surfaces are suitable for a wide range of numerical methods and solvers, as demonstrated in an application derived from transcranial alternating current stimulation. The platform was validated against literature data, e.g., on the SENN [1] model which was further extended to account for local thermal effects. Additionally, the EM-neuron coupling simulation platform was also applied to investigate MRI gradient coil switching induced nerve stimulation.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Computational platform combining detailed and precise functionalized anatomical phantoms with EM-Neuron interaction modeling
A computational framework including functionalized anatomical phantoms able to simulate electromagnetic (EM)-neuron interactions in complex tissue-structure environments was developed. The anatomic head model distinguishes a large number of structures, particularly in regions relevant to EM-neuron interactions (i.e., ear, eye, deep brain structures). Multimodal Magnetic Resonance (MR) images were acquired together with Diffusion Tensor Imaging (DTI) data to guide neuron model placement and inform about tissue anisotropy. A dedicated EM solver was implemented and coupled with dynamic models of neuronal activity. The topologically conforming, non-self-intersecting, high-element-quality surfaces are suitable for a wide range of numerical methods and solvers, as demonstrated in an application derived from transcranial alternating current stimulation. The platform was validated against literature data, e.g., on the SENN [1] model which was further extended to account for local thermal effects. Additionally, the EM-neuron coupling simulation platform was also applied to investigate MRI gradient coil switching induced nerve stimulation.
- 1 April 2012
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 205 (2) , 223-232
A novel high electrode count spike recording array using an 81,920 pixel transimpedance amplifier-based imaging chip
- 1 April 2012
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 205 (2) , 223-232
A novel high electrode count spike recording array using an 81,920 pixel transimpedance amplifier-based imaging chip