Background suppression single-shot electrocardiogram trigger non-enhanced magnetic resonance angiography in lower extremity blood vessels: a comparative study
Open Access
- 1 February 2025
- journal article
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1312-1323
Abstract
Background: Background suppression single-shot electrocardiogram trigger non-contrast-enhanced magnetic resonance angiography (BASS-TRANCE) is a recently introduced non-contrast-enhanced magnetic resonance angiography (NCE-MRA) technique. It was reported to be a practical test for the evaluation of peripheral artery disease (PAD) with an imaging performance comparable to that of the known NCE-MRA technique quiescent interval single-shot (QISS). However, its performance compared to the most commonly used diagnostic methods for digital subtraction angiography (DSA) and computed tomography angiography (CTA) remains unclear. Using DSA as the test standard, this study evaluated the image quality and clinical diagnostic accuracy of BASS-TRANCE and CTA in PAD patients. Methods: BASS-TRANCE, CTA, and DSA were examined successively in 30 patients with PAD. Two senior physicians scored the image quality of CTA and BASS-TRANCE using the 3-point method, and the images of both were evaluated according to the 5-level stenosis evaluation method. Either paired t-test or Wilcoxon signed-rank test was used to compare the difference of image quality between the two groups. Using DSA results as the gold standard, the sensitivity and specificity of CTA and BASS-TRANCE for lower limb artery stenosis >50% were calculated by McNemar’s test. Results: Of 570 segments, 12 (2.1%) and 42 (7.4%) inconclusive segments were excluded from BASS-TRANCE and CTA analysis, respectively (P0.05]. Furthermore, BASS-TRANCE demonstrated significant efficacy in detecting vascular stenosis with a sensitivity of 92.8% and specificity of 96.1%, which were comparable to those achieved by CTA (94.9% and 96.8%, respectively). Conclusions: As an NCE-MRA technique, BASS-TRANCE can display the lower extremity vessels in a short time; it is expected to replace CTA as a safe and effective examination method for PAD patients in the future.Keywords
This publication has 37 references indexed in Scilit:
- Meta-analysis: Accuracy of Contrast-Enhanced Magnetic Resonance Angiography for Assessing Steno-occlusions in Peripheral Arterial DiseaseAnnals of Internal Medicine, 2010
- Quiescent-interval single-shot unenhanced magnetic resonance angiography of peripheral vascular disease: Technical considerations and clinical feasibilityMagnetic Resonance in Medicine, 2010
- 3D noncontrast MR angiography of the distal lower extremities using flow‐sensitive dephasing (FSD)‐prepared balanced SSFPMagnetic Resonance in Medicine, 2009
- Optimal Vascular and Parenchymal Contrast Enhancement: The Current State of the ArtRadiologic Clinics of North America, 2009
- Incidence of Nephrogenic Systemic Fibrosis at Two Large Medical CentersRadiology, 2008
- Nonenhanced MR AngiographyRadiology, 2008
- 3D nongadolinium‐enhanced ECG‐gated MRA of the distal lower extremities: Preliminary clinical experienceJournal of Magnetic Resonance Imaging, 2008
- Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filtersJournal of Magnetic Resonance Imaging, 2007
- Vessel Wall Calcifications at Multi–Detector Row CT Angiography in Patients with Peripheral Arterial Disease: Effect on Clinical Utility and Clinical PredictorsRadiology, 2006
- Diabetes and Peripheral Arterial Occlusive DiseaseAmerican Journal of Roentgenology, 2000