Xingyue Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xingyue Jiang has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Beizhong Wang
Department of Radiology, Binzhou Medical University Hospital, Binzhou, China
1 shared publication- Bin Wang
Medical Imaging Research Institute, Binzhou Medical University, Yantai, China
1 shared publication Chang-Jin Bao
Department of Radiology, Affiliated Hospital of Binzhou Medical College, Binzhou, China
1 shared publicationChengyan Wang
Department of Radiology, Binzhou Medical University Hospital, Binzhou, China
1 shared publicationChuanmei Wei
Department of Pharmacy Binzhou Medical University Hospital Binzhou Shandong P. R. China
1 shared publicationDonghao Xu
School of Medical Imaging, Binzhou Medical University, Yantai, China
1 shared publication
Latest Publications
- Open Access
- 1 February 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1312-1323
Background suppression single-shot electrocardiogram trigger non-enhanced magnetic resonance angiography in lower extremity blood vessels: a comparative study
Background: Background suppression single-shot electrocardiogram trigger non-contrast-enhanced magnetic resonance angiography (BASS-TRANCE) is a recently introduced non-contrast-enhanced magnetic resonance angiography (NCE-MRA) technique. It was reported to be a practical test for the evaluation of peripheral artery disease (PAD) with an imaging performance comparable to that of the known NCE-MRA technique quiescent interval single-shot (QISS). However, its performance compared to the most commonly used diagnostic methods for digital subtraction angiography (DSA) and computed tomography angiography (CTA) remains unclear. Using DSA as the test standard, this study evaluated the image quality and clinical diagnostic accuracy of BASS-TRANCE and CTA in PAD patients. Methods: BASS-TRANCE, CTA, and DSA were examined successively in 30 patients with PAD. Two senior physicians scored the image quality of CTA and BASS-TRANCE using the 3-point method, and the images of both were evaluated according to the 5-level stenosis evaluation method. Either paired t-test or Wilcoxon signed-rank test was used to compare the difference of image quality between the two groups. Using DSA results as the gold standard, the sensitivity and specificity of CTA and BASS-TRANCE for lower limb artery stenosis >50% were calculated by McNemar’s test. Results: Of 570 segments, 12 (2.1%) and 42 (7.4%) inconclusive segments were excluded from BASS-TRANCE and CTA analysis, respectively (P0.05]. Furthermore, BASS-TRANCE demonstrated significant efficacy in detecting vascular stenosis with a sensitivity of 92.8% and specificity of 96.1%, which were comparable to those achieved by CTA (94.9% and 96.8%, respectively). Conclusions: As an NCE-MRA technique, BASS-TRANCE can display the lower extremity vessels in a short time; it is expected to replace CTA as a safe and effective examination method for PAD patients in the future.
- 1 February 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (2) , 1312-1323
Open AccessBackground suppression single-shot electrocardiogram trigger non-enhanced magnetic resonance angiography in lower extremity blood vessels: a comparative study
Background: Background suppression single-shot electrocardiogram trigger non-contrast-enhanced magnetic resonance angiography (BASS-TRANCE) is a recently introduced non-contrast-enhanced magnetic resonance angiography (NCE-MRA) technique. It was reported to be a practical test for the evaluation of peripheral artery disease (PAD) with an imaging performance comparable to that of the known NCE-MRA technique quiescent interval single-shot (QISS). However, its performance compared to the most commonly used diagnostic methods for digital subtraction angiography (DSA) and computed tomography angiography (CTA) remains unclear. Using DSA as the test standard, this study evaluated the image quality and clinical diagnostic accuracy of BASS-TRANCE and CTA in PAD patients. Methods: BASS-TRANCE, CTA, and DSA were examined successively in 30 patients with PAD. Two senior physicians scored the image quality of CTA and BASS-TRANCE using the 3-point method, and the images of both were evaluated according to the 5-level stenosis evaluation method. Either paired t-test or Wilcoxon signed-rank test was used to compare the difference of image quality between the two groups. Using DSA results as the gold standard, the sensitivity and specificity of CTA and BASS-TRANCE for lower limb artery stenosis >50% were calculated by McNemar’s test. Results: Of 570 segments, 12 (2.1%) and 42 (7.4%) inconclusive segments were excluded from BASS-TRANCE and CTA analysis, respectively (P0.05]. Furthermore, BASS-TRANCE demonstrated significant efficacy in detecting vascular stenosis with a sensitivity of 92.8% and specificity of 96.1%, which were comparable to those achieved by CTA (94.9% and 96.8%, respectively). Conclusions: As an NCE-MRA technique, BASS-TRANCE can display the lower extremity vessels in a short time; it is expected to replace CTA as a safe and effective examination method for PAD patients in the future.
- 4 May 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (10) , 3383-3396
Interpretable machine learning based on CT-derived extracellular volume fraction to predict pathological grading of hepatocellular carcinoma
Purpose To develop a non-invasive auxiliary assessment method based on CT-derived extracellular volume (ECV) to predict the pathological grading (PG) of hepatocellular carcinoma (HCC). Methods The study retrospectively analyzed 238 patients who underwent HCC resection surgery between January 2013 and April 2023. Six machine learning algorithms were employed to construct predictive models for HCC PG: logistic regression, extreme gradient boosting, Light Gradient Boosting Machine (LightGBM), random forest, adaptive boosting, and Gaussian naive Bayes. Model performance was evaluated using receiver operating characteristic curve analysis, including area under the curve (AUC), sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and F1 score. Calibration plots were used for visual evaluation of model calibration. Clinical decision curve analysis was performed to assess potential clinical utility by calculating net benefit. Results 166 patients from Hospital A were allocated to the training set, while 72 patients from Hospital B (constituting 30.25% of the total sample) were assigned to the test set. The model achieved an AUC of 1.000 (95%CI: 1.000–1.000) in the training set and 0.927 (95%CI: 0.837–0.999) in the validation set, respectively. Ultimately, the model achieved an AUC of 0.909 (95%CI: 0.837–0.980) in the test set, with an accuracy of 0.778, sensitivity of 0.906, specificity of 0.789, negative predictive value of 0.556, and F1 score of 0.908. Conclusion This study successfully developed and validated a non-invasive auxiliary assessment method based on CT-derived ECV to predict the HCC PG, providing important supplementary information for clinical decision-making.
- 4 May 2024
- Published by Springer Nature in Abdominal Radiology
- Vol. 49 (10) , 3383-3396
Interpretable machine learning based on CT-derived extracellular volume fraction to predict pathological grading of hepatocellular carcinoma
Purpose To develop a non-invasive auxiliary assessment method based on CT-derived extracellular volume (ECV) to predict the pathological grading (PG) of hepatocellular carcinoma (HCC). Methods The study retrospectively analyzed 238 patients who underwent HCC resection surgery between January 2013 and April 2023. Six machine learning algorithms were employed to construct predictive models for HCC PG: logistic regression, extreme gradient boosting, Light Gradient Boosting Machine (LightGBM), random forest, adaptive boosting, and Gaussian naive Bayes. Model performance was evaluated using receiver operating characteristic curve analysis, including area under the curve (AUC), sensitivity, specificity, accuracy, positive predictive value, negative predictive value, and F1 score. Calibration plots were used for visual evaluation of model calibration. Clinical decision curve analysis was performed to assess potential clinical utility by calculating net benefit. Results 166 patients from Hospital A were allocated to the training set, while 72 patients from Hospital B (constituting 30.25% of the total sample) were assigned to the test set. The model achieved an AUC of 1.000 (95%CI: 1.000–1.000) in the training set and 0.927 (95%CI: 0.837–0.999) in the validation set, respectively. Ultimately, the model achieved an AUC of 0.909 (95%CI: 0.837–0.980) in the test set, with an accuracy of 0.778, sensitivity of 0.906, specificity of 0.789, negative predictive value of 0.556, and F1 score of 0.908. Conclusion This study successfully developed and validated a non-invasive auxiliary assessment method based on CT-derived ECV to predict the HCC PG, providing important supplementary information for clinical decision-making.
- Open Access
- 10 April 2024
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 28 (8) , e18285
Engeletin alleviates depressive‐like behaviours by modulating microglial polarization via the LCN2/CXCL10 signalling pathway
Microglial polarization and associated inflammatory activity are the key mediators of depression pathogenesis. The natural Smilax glabra rhizomilax derivative engeletin has been reported to exhibit robust anti‐inflammatory activity, but no studies to date have examined the mechanisms through which it can treat depressive symptoms. We showed that treatment for 21 days with engeletin significantly alleviated depressive‐like behaviours in chronic stress social defeat stress (CSDS) model mice. T1‐weighted imaging (T1WI), T2‐weighted imaging (T2WI) imaging revealed no significant differences between groups, but the bilateral prefrontal cortex of CSDS mice exhibited significant increases in apparent diffusion coefficient and T2 values relative to normal control mice, with a corresponding reduction in fractional anisotropy, while engeletin reversed all of these changes. CSDS resulted in higher levels of IL‐1β, IL‐6, and TNF‐a production, enhanced microglial activation, and greater M1 polarization with a concomitant decrease in M2 polarization in the mPFC, whereas engeletin treatment effectively abrogated these CSDS‐related pathological changes. Engeletin was further found to suppress the LCN2/C‐X‐C motif chemokine ligand 10 (CXCL10) signalling axis such that adeno‐associated virus‐induced LCN2 overexpression ablated the antidepressant effects of engeletin and reversed its beneficial effects on the M1/M2 polarization of microglia. In conclusion, engeletin can alleviate CSDS‐induced depressive‐like behaviours by regulating the LCN2/CXCL10 pathway and thereby altering the polarization of microglia. These data suggest that the antidepressant effects of engeletin are correlated with the polarization of microglia, highlighting a potential avenue for future design of antidepressant strategies that specifically target the microglia.
- 10 April 2024
- Published by Wiley in Journal of Cellular and Molecular Medicine
- Vol. 28 (8) , e18285
Open AccessEngeletin alleviates depressive‐like behaviours by modulating microglial polarization via the LCN2/CXCL10 signalling pathway
Microglial polarization and associated inflammatory activity are the key mediators of depression pathogenesis. The natural Smilax glabra rhizomilax derivative engeletin has been reported to exhibit robust anti‐inflammatory activity, but no studies to date have examined the mechanisms through which it can treat depressive symptoms. We showed that treatment for 21 days with engeletin significantly alleviated depressive‐like behaviours in chronic stress social defeat stress (CSDS) model mice. T1‐weighted imaging (T1WI), T2‐weighted imaging (T2WI) imaging revealed no significant differences between groups, but the bilateral prefrontal cortex of CSDS mice exhibited significant increases in apparent diffusion coefficient and T2 values relative to normal control mice, with a corresponding reduction in fractional anisotropy, while engeletin reversed all of these changes. CSDS resulted in higher levels of IL‐1β, IL‐6, and TNF‐a production, enhanced microglial activation, and greater M1 polarization with a concomitant decrease in M2 polarization in the mPFC, whereas engeletin treatment effectively abrogated these CSDS‐related pathological changes. Engeletin was further found to suppress the LCN2/C‐X‐C motif chemokine ligand 10 (CXCL10) signalling axis such that adeno‐associated virus‐induced LCN2 overexpression ablated the antidepressant effects of engeletin and reversed its beneficial effects on the M1/M2 polarization of microglia. In conclusion, engeletin can alleviate CSDS‐induced depressive‐like behaviours by regulating the LCN2/CXCL10 pathway and thereby altering the polarization of microglia. These data suggest that the antidepressant effects of engeletin are correlated with the polarization of microglia, highlighting a potential avenue for future design of antidepressant strategies that specifically target the microglia.
- 1 May 2019
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 46 (3) , 186-192
Can dynamic contrast-enhanced MRI evaluate VEGF expression in brain glioma? An MRI-guided stereotactic biopsy study
- 1 May 2019
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 46 (3) , 186-192
Can dynamic contrast-enhanced MRI evaluate VEGF expression in brain glioma? An MRI-guided stereotactic biopsy study
- Open Access
- 22 January 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (5) , 855-860
Evaluation of Virtual Noncontrast Images Obtained from Dual-Energy CTA for Diagnosing Subarachnoid Hemorrhage
BACKGROUND AND PURPOSE: The virtual noncontrast images generated with iodine subtraction from dual-energy CTA images are expected to replace the true noncontrast images for radiation-dose reduction. This study assessed the feasibility of virtual noncontrast images for diagnosing SAH. MATERIALS AND METHODS: Eighty-four patients with or without SAH underwent true noncontrast brain CT (the criterion standard for diagnosing SAH). Among them, 37 patients underwent an additional head dual-energy angiography, and the other patients underwent head and neck dual-energy angiography. Virtual noncontrast images were produced on a dedicated dual-energy postprocessing workstation and reconstructed in orientation and section width identical to those in true noncontrast images. The findings on the virtual noncontrast and true noncontrast images were compared at both the individual level and the lesion level. Image noise of the virtual noncontrast and true noncontrast images was also measured and compared. The volume CT dose index and dose-length product were recorded for the radiation-dose analysis. RESULTS: The sensitivity, specificity, positive predictive value, and negative predictive value of virtual noncontrast images at the individual level and the lesion level were 94.5%, 100%, 100%, 90.6% and 86.7%, 96.9%, 91.8%, 94.8%, respectively. The agreement in the diagnosis of SAH on true noncontrast and virtual noncontrast images reached 92.3% at the individual level and 85.1% at the lesion level. The virtual noncontrast images showed a higher image noise level. The volume CT dose index and dose-length product were obviously reduced without the true noncontrast brain CT scan. CONCLUSIONS: Virtual noncontrast images are a reliable tool for diagnosing SAH, with the advantage of reducing the radiation dose.
- 22 January 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (5) , 855-860
Open AccessEvaluation of Virtual Noncontrast Images Obtained from Dual-Energy CTA for Diagnosing Subarachnoid Hemorrhage
BACKGROUND AND PURPOSE: The virtual noncontrast images generated with iodine subtraction from dual-energy CTA images are expected to replace the true noncontrast images for radiation-dose reduction. This study assessed the feasibility of virtual noncontrast images for diagnosing SAH. MATERIALS AND METHODS: Eighty-four patients with or without SAH underwent true noncontrast brain CT (the criterion standard for diagnosing SAH). Among them, 37 patients underwent an additional head dual-energy angiography, and the other patients underwent head and neck dual-energy angiography. Virtual noncontrast images were produced on a dedicated dual-energy postprocessing workstation and reconstructed in orientation and section width identical to those in true noncontrast images. The findings on the virtual noncontrast and true noncontrast images were compared at both the individual level and the lesion level. Image noise of the virtual noncontrast and true noncontrast images was also measured and compared. The volume CT dose index and dose-length product were recorded for the radiation-dose analysis. RESULTS: The sensitivity, specificity, positive predictive value, and negative predictive value of virtual noncontrast images at the individual level and the lesion level were 94.5%, 100%, 100%, 90.6% and 86.7%, 96.9%, 91.8%, 94.8%, respectively. The agreement in the diagnosis of SAH on true noncontrast and virtual noncontrast images reached 92.3% at the individual level and 85.1% at the lesion level. The virtual noncontrast images showed a higher image noise level. The volume CT dose index and dose-length product were obviously reduced without the true noncontrast brain CT scan. CONCLUSIONS: Virtual noncontrast images are a reliable tool for diagnosing SAH, with the advantage of reducing the radiation dose.