Aortic pulse wave velocity measurements with undersampled 4D flow‐sensitive MRI: comparison with 2D and algorithm determination
Open Access
- 2 November 2012
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (4) , 853-859
Abstract
Purpose: To compare pulse wave velocity (PWV) measurements obtained from radially undersampled 4D phase‐contrast magnetic resonance imaging (PC‐MRI) with 2D PC measurements and to evaluate four PWV algorithms.Materials and Methods: PWV was computed from radially undersampled 3D, 3‐directionally velocity‐encoded PC‐MRI (4D) acquisitions performed on a 3T MR scanner in 18 volunteers. High temporal resolution 2D PC scans serving as a reference standard were available in 14 volunteers. Four PWV algorithms were tested: time‐to‐upstroke (TTU), time‐to‐peak (TTP), time‐to‐foot (TTF), and cross‐correlation (XCorr). Bland–Altman analysis was used to determine inter‐ and intraobserver reproducibility and to compare differences between algorithms. Differences in age and PWV measurements were analyzed with Student's t‐tests. The variability of age‐corrected data was assessed with a Brown‐Forsythe analysis of variance (ANOVA) test.Results: 2D (4.6–5.3 m/s) and 4D (3.8–4.8 m/s) PWV results were in agreement with previously reported values in healthy subjects. Of the four PWV algorithms, the TTU, TTF, and XCorr algorithms gave similar and reliable results. Average biases of +0.30 m/s and −0.01 m/s were determined for intra‐ and interobserver variability, respectively. The Brown‐Forsythe test revealed that no differences in variability could be found between 2D and 4D PWV measurements.Conclusion: 4D PC‐MRI with radial undersampling provides reliable and reproducible measurements of PWV. TTU, TTF, and XCorr were the preferred PWV algorithms. J. Magn. Reson. Imaging 2013;37:853–859.Keywords
This publication has 26 references indexed in Scilit:
- Determinants of pulse wave velocity in healthy people and in the presence of cardiovascular risk factors: ‘establishing normal and reference values’European Heart Journal, 2010
- Estimation of global aortic pulse wave velocity by flow‐sensitive 4D MRIMagnetic Resonance in Medicine, 2010
- Accuracy and repeatability of fourier velocity encoded M‐mode and two‐dimensional cine phase contrast for pulse wave velocity measurement in the descending aortaJournal of Magnetic Resonance Imaging, 2010
- Improved SNR in phase contrast velocimetry with five‐point balanced flow encodingMagnetic Resonance in Medicine, 2010
- Validation and reproducibility of aortic pulse wave velocity as assessed with velocity‐encoded MRIJournal of Magnetic Resonance Imaging, 2009
- Improved 3D phase contrast MRI with off‐resonance corrected dual echo VIPRMagnetic Resonance in Medicine, 2008
- A new method for the determination of aortic pulse wave velocity using cross‐correlation on 2D PCMR velocity dataJournal of Magnetic Resonance Imaging, 2008
- Feasibility of aortic pulse pressure and pressure wave velocity MRI measurement in young adultsJournal of Magnetic Resonance Imaging, 2004
- Aortic Stiffness Is an Independent Predictor of Fatal Stroke in Essential HypertensionStroke, 2003
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986