Abstract
Agricultural hybrid vehicles demand propulsion systems that are not only efficient but also fault-tolerant, enabling enhanced lifespan of motor drives, increasing MTBF, and reducing maintenance costs. In this context, this article implements an open-circuit fault diagnosis and leverages the inherent fault-tolerant capabilities in a 30 kW four-phase H bridge converter by examining its speed control at rated load during sequential fault events on each phase. Results show that the SRM drive is capable of mitigating open-circuit faults while maintaining speed regulation performance. Diagnosis delay took 258 processing cycles. Proposed system is also tested under a relevant agricultural driving cycle at close-to-rated speed and torque. Mean squared error between desired and actual speed resulted in 0.4455%.

This publication has 21 references indexed in Scilit: