Performance Evaluation of Gas Chromatography–Atmospheric Pressure Chemical Ionization–Time-of-Flight Mass Spectrometry for Metabolic Fingerprinting and Profiling
Authors:
- 22 August 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (19) , 7514-7522
Abstract
Gas chromatography–atmospheric-pressure chemical ionization–time-of-flight mass spectrometry (GC–APCI–TOFMS) was compared to GC × GC–electron ionization (EI)–TOFMS, GC–EI–TOFMS, GC–chemical ionization (CI)–quadrupole mass spectrometry (qMS), and GC–EI–qMS in terms of reproducibility, dynamic range, limit of detection, and quantification using a mix of 43 metabolites and 12 stable isotope-labeled standards. Lower limits of quantification for GC–APCI–TOFMS ranged between 0.06 and 7.81 μM, and relative standard deviations for calibration replicates were between 0.4% and 8.7%. For all compounds and techniques, except in four cases, R2 values were above 0.99. Regarding limits of quantification, GC–APCI–TOFMS was inferior to only GC × GC–EI–TOFMS, but outperformed all other techniques tested. GC–APCI–TOFMS was further applied to the metabolic fingerprinting of two Escherichia coli strains. Of 45 features that differed significantly (false discovery rate < 0.05) between the strains, 25 metabolites were identified through highly accurate and reproducible (Δm ± SD below 5 mDa over m/z 190–722) mass measurements. Starting from the quasimolecular ion, six additional metabolites were identified that had not been found in a previous study using GC × GC–EI–TOFMS and an EI mass spectral library for identification purposes. Silylation adducts formed in the APCI source assisted the identification of unknown compounds, as their formation is structure-dependent and is not observed for compounds lacking a carboxylic group.Keywords
This publication has 23 references indexed in Scilit:
- Gas chromatography–atmospheric pressure chemical ionization-time of flight mass spectrometry for profiling of phenolic compounds in extra virgin olive oilJournal of Chromatography A, 2011
- The application of gas chromatography/atmospheric pressure chemical ionisation time‐of‐flight mass spectrometry to impurity identification in Pharmaceutical DevelopmentRapid Communications in Mass Spectrometry, 2010
- Gas Chromatography/Atmospheric Pressure Chemical Ionization-Time of Flight Mass Spectrometry: Analytical Validation and Applicability to Metabolic ProfilingAnalytical Chemistry, 2009
- Integrative Normalization and Comparative Analysis for Metabolic Fingerprinting by Comprehensive Two-Dimensional Gas Chromatography−Time-of-Flight Mass SpectrometryAnalytical Chemistry, 2009
- Development of a multipurpose ion source for LC-MS and GC-API MSAnalytical and Bioanalytical Chemistry, 2008
- Seven Golden Rules for heuristic filtering of molecular formulas obtained by accurate mass spectrometryBMC Bioinformatics, 2007
- Metabolomic database annotations via query of elemental compositions: Mass accuracy is insufficient even at less than 1 ppmBMC Bioinformatics, 2006
- A combination atmospheric pressure LC/MS:GC/MS ion source: Advantages of dual AP-LC/MS:GC/MS instrumentationJournal of the American Society for Mass Spectrometry, 2005
- Combined capillary gas chromatography/atmospheric pressure negative chemical ionization/mass spectrometry for the determination of 2,3,7,8-tetrachlorodibenzo-p-dioxin in tissueAnalytical Chemistry, 1980
- New picogram detection system based on a mass spectrometer with an external ionization source at atmospheric pressureAnalytical Chemistry, 1973