Abstract
Purpose: This prospective study evaluated implant survival rates and crestal bone changes for porous oxide‐coated (TiUnite, Nobel Biocare AB, Gothenburg, Sweden), parallel‐walled implants.Materials and Methods: All patients receiving TiUnite (porous oxide‐surfaced implants [POS]) implants were entered into a database (Triton Tracking System) starting February 1999. Survival rates were calculated from the date of implant placement and related to surgical method of placement (two‐stage buried, flapless, immediate placement, immediate placement flapless, one stage), bone quality, and implant characteristics. Failed and nonfailed implants were compared with respect to changes in mean proximal bone levels and the presence of radiolucent areas around the implant apex (shadows).Results: Four hundred nine patients received 817 porous oxide‐coated implants, of which 38 failed. Using the last office visit as the censoring date, the cumulative survival date was 93%. The failure rate was independent of bone quality or quantity; implant diameter or length; and surgical method. For the 102 surviving implants, there was no significant change in the average crestal bone loss (+0.13 mm with a standard error, 0.17). For the 17 failing implants, the average crestal bone loss was −4.14 mm (standard error, 0.55). This difference between bone levels of failing and nonfailing implants was highly significant (p < .0001). There was no difference in the prevalence of radiographic shadows around failing and nonfailing implants at time of placement (p < .16).Conclusion: Results from this prospective clinical study indicate that 7% of TiUnite surfaced implants failed for unknown reasons. Failing implants were characterized by significant bone loss but not by the presence of shadows.Keywords
This publication has 18 references indexed in Scilit:
- Monitoring Failure Rates of Commercial Implant Brands; Substantial Equivalence in Question?Clinical Oral Implants Research, 2012
- Implants with an Oxidized Surface Placed Predominately in Soft Bone Quality and Subjected to Immediate Occlusal Loading: Results from a 7‐Year Clinical Follow‐UpClinical Implant Dentistry and Related Research, 2011
- Minimally Invasive Flapless Implant Placement: Follow‐Up Results From a Multicenter StudyJournal of Periodontology, 2009
- Ridge alterations following immediate implant placement in the dog: flap versus flapless surgeryJournal of Clinical Periodontology, 2008
- One‐Year Results of a Prospective Multicenter Study on Brånemark System® Implants with a TiUnite™ SurfaceClinical Implant Dentistry and Related Research, 2005
- Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two‐stage protocolClinical Oral Implants Research, 2005
- Immediate Implant Placement: A Procedure Without IncisionsJournal of Periodontology, 1998
- Ten‐year survival rates of fixed prostheses on four or six implants ad modum Brånemark in full edentulismClinical Oral Implants Research, 1995
- Clinical and radiographical features of submerged and nonsubmerged titanium implantsClinical Oral Implants Research, 1994
- Osseointegrated Titanium Implants:Requirements for Ensuring a Long-Lasting, Direct Bone-to-Implant Anchorage in ManActa Orthopaedica, 1981