Dosimetric effect of respiration-gated beam on IMRT delivery
Authors:
- 25 July 2003
- journal article
- Published by Wiley in Medical Physics
- Vol. 30 (8) , 2241-2252
Abstract
Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study was to investigate the effect of leaf lag on the accuracy of doses delivered in gated IMRT. We first determined the effective leaf delay time by measuring the dose in a stationary phantom delivered by wedge-shaped fields. The wedge fields were generated by a DMLC at various dose rates. The so determined delay varied from 88.3 to 90.5 ms. The dosimetric effect of this delay on gated IMRT was studied by delivering wedge-shaped and clinical IMRT fields to moving and stationary phantoms at dose rates ranging from 100 to 600 MU/min, with and without gating. Respiratory motion was simulated by a linear sinusoidal motion of the phantom. An ionization chamber and films were employed for absolute dose and 2-D dose distribution measurements. Discrepancies between gated and nongated delivery to the stationary phantom were observed in both absolute dose and 2-D dose distribution measurements. These discrepancies increased monotonically with dose rate and frequency of beam interruptions, and could reach 3.7% of the total dose delivered to a 0.6 cm3 ion chamber. Isodose lines could be shifted by as much as 3 mm. The results are consistent with the explanation that beam hold-offs in gated delivery allowed the lagging leaves to catch up with the delivered monitor units each time that the beam was interrupted. Low dose rates, slow leaf speeds and low frequencies of beam interruptions reduce the effect of this delay-and-catch-up cycle. For gated IMRT it is therefore important to find a good balance between the conflicting requirements of rapid dose delivery and delivery accuracy.Keywords
This publication has 22 references indexed in Scilit:
- Patient specific quality assurance for the delivery of intensity modulated radiotherapyJournal of Applied Clinical Medical Physics, 2003
- Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator systemMedical Physics, 2002
- Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancerMedical Physics, 2002
- Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Comprehensive quality assurance for the delivery of intensity modulated radiotherapy with a multileaf collimator used in the dynamic modeMedical Physics, 2001
- Compatibility of Varian 2100C gated operations with enhanced dynamic wedge and IMRT dose deliveryMedical Physics, 2000
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998
- Testing of dynamic multileaf collimationMedical Physics, 1996
- Irradiation synchronized with respiration gateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1989