  • Dosimetric and radiobiological impact of dose fractionation on respiratory motion induced IMRT delivery errors: A volumetric dose measurement study

    by Jun Duan, Sui Shen, John B. Fiveash, Richard A. Popple, Ivan A. Brezovich

    Respiratory motion can introduce substantial dose errors during IMRT delivery. These errors are difficult to predict because of the nonsynchronous interplay between radiation beams and tissues. The present study investigates the impact of dose fractionation on respiratory motion induced dosimetric errors during IMRT delivery and their radiobiological implications by using measured 3D dose. We focused on IMRT delivery with dynamic multileaf collimation (DMLC‐IMRT). IMRT plans using several beam arrangements were optimized for and delivered to a polystyrene phantom containing a simulated target and critical organs. The phantom was set in linear sinusoidal motion at a frequency of . The amplitude of the motion was in the longitudinal direction and in the lateral direction. Absolute doses were measured with a ionization chamber while dose distributions were measured with transverse films spaced apart. Measurements were performed for varying number of fractions with motion, with respiratory‐gated motion, and without motion. A tumor control probability (TCP) model for an inhomogeneously irradiated tumor was used to calculate and compare TCPs for the measurements and the treatment plans. Equivalent uniform doses (EUD) were also computed. For individual fields, point measurements using an ionization chamber showed substantial dose deviations ( to ) for the moving phantom as compared to the stationary phantom. However, much smaller deviations ( to ) were observed for the composite dose of all fields. The dose distributions and DVHs of stationary and gated deliveries were in good agreement with those of treatment plans, while those of the nongated moving phantom showed substantial differences. Compared to the stationaryphantom, the largest differences observed for the minimum and maximum target doses were and , respectively. Due to their random nature, these dose errors tended to average out over fractionated treatments. The results of five‐fraction measurements showed significantly improved agreement between the moving and stationary phantom. The changes in TCP were less than 4.3% for a single fraction, and less than 2.3% for two or more fractions. Variation of average EUD per fraction was small ( for a fraction size of ), even when the DVHs were noticeably different from that of the stationary tumor. In conclusion, IMRT treatment of sites affected by respiratory motion can introduce significant dose errors in individual field doses; however, these errors tend to cancel out between fields and average out over dose fractionation. 3D dose distributions, DVHs, TCPs, and EUDs for stationary and moving cases showed good agreement after two or more fractions, suggesting that tumors affected by respiration motion may be treated using IMRT without significant dosimetric and biological consequences.


  • A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT

    by Jun Duan, Sui Shen, Sharon A. Spencer, Raef S. Ahmed, Richard A. Popple, Sung-Joon Ye, Ivan A. Brezovich


  • A dynamic supraclavicular field-matching technique for head-and-neck cancer patients treated with IMRT

    by Jun Duan, Sui Shen, Sharon A. Spencer, Raef S. Ahmed, Richard A. Popple, Sung-Joon Ye, Ivan A. Brezovich


  • Dosimetric effect of respiration-gated beam on IMRT delivery

    by Jun Duan, Sui Shen, John B. Fiveash, Ivan A. Brezovich, Richard A. Popple, Prem. N. Pareek

    Intensity modulated radiation therapy (IMRT) with a dynamic multileaf collimator (DMLC) requires synchronization of DMLC leaf motion with dose delivery. A delay in DMLC communication is known to cause leaf lag and lead to dosimetric errors. The errors may be exacerbated by gated operation. The purpose of this study was to investigate the effect of leaf lag on the accuracy of doses delivered in gated IMRT. We first determined the effective leaf delay time by measuring the dose in a stationary phantom delivered by wedge-shaped fields. The wedge fields were generated by a DMLC at various dose rates. The so determined delay varied from 88.3 to 90.5 ms. The dosimetric effect of this delay on gated IMRT was studied by delivering wedge-shaped and clinical IMRT fields to moving and stationary phantoms at dose rates ranging from 100 to 600 MU/min, with and without gating. Respiratory motion was simulated by a linear sinusoidal motion of the phantom. An ionization chamber and films were employed for absolute dose and 2-D dose distribution measurements. Discrepancies between gated and nongated delivery to the stationary phantom were observed in both absolute dose and 2-D dose distribution measurements. These discrepancies increased monotonically with dose rate and frequency of beam interruptions, and could reach 3.7% of the total dose delivered to a 0.6 cm3 ion chamber. Isodose lines could be shifted by as much as 3 mm. The results are consistent with the explanation that beam hold-offs in gated delivery allowed the lagging leaves to catch up with the delivered monitor units each time that the beam was interrupted. Low dose rates, slow leaf speeds and low frequencies of beam interruptions reduce the effect of this delay-and-catch-up cycle. For gated IMRT it is therefore important to find a good balance between the conflicting requirements of rapid dose delivery and delivery accuracy.


  • Open Access

    A self‐correcting method for improving the precision of beam blocks

    by Ivan A. Brezovich, Karen S. Sparks, Jun Duan

    A technique for manufacturing precise custom blocks is described. Using the tracing stylus of the mold making machine, reference markers are cut into the lateral borders of the polystyrene mold after the cavities for the blocks have been made. These markers are aligned with the central ray cross hair of the shadow tray when the blocks are mounted on the tray. The ability of the technique to enhance precision has been verified in laboratory tests by intentionally introducing small imperfections into a mold making machine and checking the positional accuracy of the mounted blocks. The clinical performance has been tested by evaluating 47 check films of blocks for 16 randomly selected patients. The average positional error of individual blocks, projected to the isocenter, was less than one mm. The average time needed to cut the reference markers was 25 seconds. Implementing the technique required only minor modifications of a commercial mold making machine.PACS number(s): 87.53.–j, 87.56.–v


  • Real-time monitoring and verification ofin vivohigh dose rate brachytherapy using a pinhole camera

    by Jun Duan, Daniel J. Macey, Prem N. Pareek, Ivan A. Brezovich

    We investigated a pinhole imaging system for independent in vivo monitoring and verification of high dose rate (HDR) brachytherapy treatment. The system consists of a high-resolution pinhole collimator, an x-ray fluoroscope, and a standard radiographic screen-film combination. Autofluoroscopy provides real-time images of the in vivo Ir-192 HDR source for monitoring the source location and movement, whereas autoradiography generates a permanent record of source positions on film. Dual-pinhole autoradiographs render stereo-shifted source images that can be used to reconstruct the source dwell positions in three dimensions. The dynamic range and spatial resolution of the system were studied with a polystyrene phantom using a range of source strengths and dwell times. For the range of source activity used in HDR brachytherapy, a 0.5 mm diameter pinhole produced sharp fluoroscopic images of the source within the dynamic range of the fluoroscope. With a source-to-film distance of 35 cm and a 400 speed screen-film combination, the same pinhole yielded well recognizable images of a 281.2 GBq (7.60 Ci) Ir-192 source for dwell times in the typical clinical range of 2 to 400 s. This 0.5 mm diameter pinhole could clearly resolve source positions separated by lateral displacements as small as 1 mm. Using a simple reconstruction algorithm, dwell positions in a phantom were derived from stereo-shifted dual-pinhole images and compared to the known positions. The agreement was better than 1 mm. A preliminary study of a patient undergoing HDR treatment for cervical cancer suggests that the imaging method is clinically feasible. Based on these studies we believe that the pinhole imaging method is capable of providing independent and reliable real-time monitoring and verification for HDR brachytherapy.