Drone-Based Quantitative Infrared Thermography (UAV-QIRT) for In Situ U-Value Estimation: A Critical Comparison of Numerical Models for Building Façades
Open Access
Abstract
Buildings account for a substantial share of global energy consumption and greenhouse gas emissions, while a large proportion of the existing building stock remains energy inefficient. Thermal transmittance is a fundamental indicator for assessing the thermal performance of historic building envelopes. This study investigates the application of UAV-based quantitative infrared thermography (UAV-QIRT) for in situ U-value measurement as an alternative to conventional methods. This study proposes a structured workflow for UAV-QIRT-based U-value measurement, developed in accordance with BS EN ISO 6781-1:2023. The study evaluates four U-value calculation formulas using thermographic data acquired during an in situ case study and compares the resulting estimates with a reference U-value obtained using the heat flow meter (HFM) method. The results demonstrate that the reliability of UAV-QIRT-based U-value estimation strongly depends on outdoor thermal boundary conditions and the physical assumptions embedded within the heat balance model. In this case, the measured exterior wall surface temperature was lower than the outdoor air temperature, causing simplified formulas to produce physically unrealistic negative U-values. In contrast, the complete heat balance model, which accounts for radiative exchanges with the sky, surroundings, and ground, as well as convective heat transfer, generated more plausible estimates. Nevertheless, significant discrepancies were observed between the UAV-QIRT and HFM estimates. Sensitivity analysis revealed a high dependence of UAV-QIRT-derived U-values on environmental boundary conditions, including wind speed, outdoor air temperature, and exterior surface temperature.Keywords
Funding Information
- Politecnico di Milano with the grant “Technical-scientific assistance activities to the Experimental Laboratories System / Laboratory of “Analysis and Diagnostics of the Built Environment
This publication has 30 references indexed in Scilit:
- Comparative assessment of quantitative infrared thermography approaches for experimental thermal transmittance determination using UAVsBuilding and Environment, 2026
- Determining overall heat transfer coefficient (U-Value) of wood-framed wall assemblies in Canada using external infrared thermographyBuilding and Environment, 2021
- A scoping review of non-destructive testing (NDT) techniques in building performance diagnostic inspectionsConstruction and Building Materials, 2020
- Quantification of heat energy losses through the building envelope: A state-of-the-art analysis with critical and comprehensive review on infrared thermographyBuilding and Environment, 2018
- Review of Unmanned Aerial System (UAS) applications in the built environment: Towards automated building inspection procedures using dronesAutomation in Construction, 2018
- A model for the improvement of thermal bridges quantitative assessment by infrared thermographyApplied Energy, 2018
- Quantitative internal infrared thermography for determining in-situ thermal behaviour of façadesEnergy and Buildings, 2017
- U-value assessment by infrared thermography: A comparison of different calculation methods in a Guarded Hot BoxEnergy and Buildings, 2016
- Diagnosis of Buildings’ Thermal Performance - A Quantitative Method Using Thermography Under Non-steady State Heat FlowEnergy Procedia, 2015
- A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittanceApplied Energy, 2015