Relationship between assistant’s lens exposure and dose information during computed tomography examinations
- 17 May 2024
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 44 (2) , 021513
Abstract
According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr−1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant’s lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant’s lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: ‘assisted ventilation,’ ‘head holding,’ ‘body holding,’ and ‘raising patient’s arm.’ The air kerma of lens position was not significantly different for each assistance type (p < 0.05, Kruskal–Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. ‘Raising patient’s arm’ and ‘head holding’ exhibited stronger correlations, which required less table movement during the CT scan than ‘assisted ventilation’ and ‘body holding’.Keywords
Funding Information
- JSPS
- KAKENHI (JP22K07793)
This publication has 23 references indexed in Scilit:
- Eye lens dose for medical staff assisting patients during computed tomography: comparison of several types of radioprotective glassesJournal of Radiological Protection, 2023
- Radiation doses to the eye lenses of radiologic technologists who assist patients undergoing computed tomographyRadiological Physics and Technology, 2021
- Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scansHeliyon, 2021
- Operator’s eye lens dose in computed tomography–guided interventionsEuropean Radiology, 2020
- Artificial Intelligence in medical imaging practice: looking to the futureJournal of Medical Radiation Sciences, 2019
- OCCUPATIONAL RADIATION EXPOSURE OF THE EYE IN NEUROVASCULAR INTERVENTIONAL PHYSICIANRadiation Protection Dosimetry, 2019
- OPTIMISATION OF SCATTER RADIATION TO STAFF DURING CT-FLUOROSCOPY: MONTE CARLO STUDIESRadiation Protection Dosimetry, 2016
- Evaluation of Radiation Exposure of Medical Staff During CT-Guided InterventionsJournal of the American College of Radiology, 2015
- Air kerma to Hp(3) conversion coefficients for a new cylinder phantom for photon reference radiation qualitiesRadiation Protection Dosimetry, 2012
- ICRP PUBLICATION 118: ICRP Statement on Tissue Reactions and Early and Late Effects of Radiation in Normal Tissues and Organs — Threshold Doses for Tissue Reactions in a Radiation Protection ContextAnnals of the ICRP, 2012