HIHajime Ito

Hajime Ito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hajime Ito has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Ikuo Kobayashi

    Research Institute of Nuclear Engineering, University of Fukui, Tsuruga, Fukui, JAPAN

    3 shared publications
  • Noriyuki Yanagawa

    Department of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1, Manabe, Tsuchiura, 300-0051, JAPAN

    3 shared publications
  • Shigehiro Ochi

    Eastern Chiba Medical Center, Togane, Japan

    3 shared publications
  • Kosuke Matsubara

    Department of Quantum Medical Technology, Faculty of Health Sciences, Institute of Medical, Pharmaceutical and Health Sciences Kanazawa University Kanazawa Ishikawa Japan

    2 shared publications
  • Takayuki Sakai

    Eastern Chiba Medical Center, Togane, Japan

    2 shared publications
  • Tomonori Isobe

    University of Tsukuba Faculty of Medicine, Tsukuba, Ibaraki, JAPAN

    2 shared publications

Latest Publications

  • Relationship between assistant’s lens exposure and dose information during computed tomography examinations

    by Hajime Ito, Kosuke Matsubara, Ikuo Kobayashi, Yurie Shimakawa, Daichi Murayama, Takayuki Sakai, Tomonori Isobe, Noriyuki Yanagawa, Shigehiro Ochi

    According to International Commission of Radiological Protection, the equivalent dose limit for the eye lens for occupational exposure is recommended to be 20 mSv yr−1, averaged over 5 years, with no single year above 50 mSv. Some studies reported the measurement of assistant’s lens exposure in diagnostic computed tomography (CT) examinations, but further investigation is still required in the association between the lens dose for assistants and various dose parameters. Therefore, we measured the assistant’s lens exposure using small optically stimulated luminescence dosimeters. The type of occupation, type of assistance, total scan time, total mAs, total scan length, and dose-length product (DLP) were recorded and analyzed in association with air kerma at the lens position. The assistance was classified into four types: ‘assisted ventilation,’ ‘head holding,’ ‘body holding,’ and ‘raising patient’s arm.’ The air kerma of lens position was not significantly different for each assistance type (p < 0.05, Kruskal–Wallis test). Further, the lens doses for assistants correlated with DLP, but with various strengths of correlation with the assistance type and were influenced by the distance from the CT gantry. In conclusion, lens dose during assistance and DLP demonstrated the strongest correlation. ‘Raising patient’s arm’ and ‘head holding’ exhibited stronger correlations, which required less table movement during the CT scan than ‘assisted ventilation’ and ‘body holding’.


  • Usefulness of a lead-acrylic shield for reducing lens dose of assistant in x-ray CT examination

    by Hajime Ito, Kosuke Matsubara, Ikuo Kobayashi, Takayuki Sakai, Tomonori Isobe, Noriyuki Yanagawa, Shigehiro Ochi

    In computed tomography (CT) examinations, the usefulness of protective glasses for reducing lens exposure to assistants has been reported. The present study aimed to compare the dose reduction effect for assistants with lead-acrylic shields and protective glasses (0.07 mm Pb, 0.5 mm Pb) during CT examination. The air dose distribution in a CT examination room with and without a lead-acrylic shield was compared. It was found that the amount of scattered radiation was significantly reduced by installing a lead-acrylic shield at the CT gantry aperture. Moreover, the reduction rate of air kerma at the assistant’s lens was higher using the lead acrylic shield than with the protective glasses—95.7% during head holding and 76.1% during assisted ventilation.


  • Evaluation of scattered radiation from fluoroscopy using small OSL dosimeters

    by Hajime Ito, Ikuo Kobayashi, Kazutoshi Watanabe, Shigehiro Ochi, Noriyuki Yanagawa

    Recently, there has been a significant amount of interest in studying the importance of radiation doses to the eye lens during endoscopic retrograde cholangiopancreatography (ERCP). A study that focused on measuring the scattered radiation using an ionization chamber survey meter reported that a lead curtain was useful in reducing the scattered radiation. The over-couch X-ray tube system tends to deliver higher doses to the head and neck of the staff involved in the procedure than the under-couch X-ray tube position. In this study, a small optically stimulated luminescence (OSL) dosimeter called the nanoDot was used to evaluate and measure the amount of radiation; this dosimeter was developed by Landauer Ltd. and was specifically designed for point measurements. There are numerous studies that have reported the usefulness of personal OSL dosimeters other than the nanoDot to measure scattered radiation. Here, we evaluated the amount of scattered radiation, along with the degree of reduction achieved with the use of a protective curtain, while employing a personal OSL dosimeter and nanoDot. When the scattered radiation dose was measured using the nanoDot, the maximum recorded value without a protective curtain was 0.363 mGy and that with a protective curtain was 0.026 mGy, both at the height of 100 cm. The maximum reduction rate of scattered radiation while using a protective curtain was approximately 93% and 97% at 100 cm and 150 cm, respectively. The measured values recorded using both personal OSL dosimeters and nanoDot machine were strongly correlated.


  • Field experience and assessment of GPS signal receiving and distribution system for synchronizing power system protection, control and monitoring

    by D. Itagaki, K. Ohashi, I. Shuto, H. Ito

    This paper describes the field experience and assessment of a GPS signal receiving and distribution system for synchronizing power system protection, control and monitoring. Application of GPS synchronization to protection, control and monitoring systems is becoming more popular in the field of power systems. However, the actual performance and reliability of GPS signal receipt within the substation environment has not been comprehensively assessed. This paper includes the system configuration for GPS synchronization, the results of our assessment of GPS synchronizing signal receipt in terms of performance and reliability. The authors introduce several techniques for reliably applying GPS synchronization to power system protection, control and monitoring especially in the event of GPS signal loss or failure. A T-RAIM, (time receiver autonomous integrity monitoring) function has been tested and the ability to maintain synchronizing signal stability was observed when a satellite anomaly occurred in January 2004. The actual service experience of a GPS based line current differential relay developed by the authors and now in commercial operation in Europe are described in this paper


  • Development of high-performance millimeter-size vibrator for cellular phones

    by H. Wakiwaka, M. Ezawa, H. Kato, W. Yoshimura, H. Ito, N. Fukuda, K. Matsuhiro