Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure
Authors:
- W. HuberWHW. Huber
- J.N. MüllerJMJ.N. Müller
- M. SchöfthalerMSM. Schöfthaler
- A. HapfelmeierAHA. Hapfelmeier
- N. LangwieserNLN. Langwieser
- J.Y. WagnerJWJ.Y. Wagner
- F. EyerFEF. Eyer
- R.M. SchmidRSR.M. Schmid
- B. SaugelBSB. Saugel
- 1 March 2014
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 112 (3) , 521-528
Abstract
Radial artery applanation tonometry technology can be used for continuous non-invasive measurement of arterial pressure (AP). The purpose of this study was to evaluate this AP monitoring technology in intensive care unit (ICU) patients in comparison with invasive AP monitoring using a radial arterial catheter. In 24 ICU patients (German university hospital), AP values were simultaneously recorded on a beat-to-beat basis using radial artery applanation tonometry (T-Line system; Tensys Medical, San Diego, CA, USA) and a radial arterial catheter (contralateral arm). The primary endpoint of the study was to investigate the accuracy and precision of the non-invasively assessed AP measurements with the Bland-Altman method based on averaged 10 beat AP epochs (n=2993 10 beat epochs). For mean AP (MAP), systolic AP (SAP), and diastolic AP (DAP), we observed a bias (±standard deviation of the bias; 95% limits of agreement; percentage error) of +2 mm Hg (±6; -11 to +15 mm Hg; 15%), -3 mm Hg (±15; -33 to +27 mm Hg; 23%), and +5 mm Hg (±7; -9 to +19 mm Hg; 22%), respectively. In ICU patients, MAP and DAP measurements obtained using radial artery applanation tonometry show clinically acceptable agreement with invasive AP determination with a radial arterial catheter. While the radial artery applanation tonometry technology also allows SAP measurements with high accuracy, its precision for SAP measurements needs to be further improved.Keywords
Funding Information
- Tensys Medical Inc.
This publication has 14 references indexed in Scilit:
- Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgeryBritish Journal of Anaesthesia, 2012
- The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patientsIntensive Care Medicine, 2012
- Noninvasive Continuous Arterial Blood Pressure Monitoring with Nexfin®Anesthesiology, 2012
- Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesiaBritish Journal of Anaesthesia, 2012
- Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometryJournal of Clinical Monitoring and Computing, 2012
- Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurementBritish Journal of Anaesthesia, 2011
- Precision and accuracy of a new device (CNAP™) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesiaBritish Journal of Anaesthesia, 2010
- An evaluation of the T‐Line ® Tensymeter continuous noninvasive blood pressure device during induced hypotension*Anaesthesia, 2008
- Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008Critical Care Medicine, 2008
- An Accuracy Evaluation of the T-Line® Tensymeter (Continuous Noninvasive Blood Pressure Management Device) versus Conventional Invasive Radial Artery Monitoring in Surgical PatientsAnesthesia & Analgesia, 2006