Comparison of methods to measure corneal power for intraocular lens power calculation using a rotating Scheimpflug camera
Authors:
- Giacomo SaviniGSGiacomo Savini
- Piero BarboniPBPiero Barboni
- Michele CarbonelliMCMichele Carbonelli
- Kenneth J. HofferKHKenneth J. Hoffer
- 1 April 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 39 (4) , 598-604
Abstract
To assess the accuracy of corneal power measurements provided by a Scheimpflug camera (Pentacam HR) for intraocular lens (IOL) power calculation in unoperated eyes and compare the results with those of simulated keratometry (SimK) performed with a Placido-disk corneal topographer (Keratron). Private practice. Evaluation of diagnostic test. Eight Scheimpflug camera corneal power measurements were analyzed: (1) average K, (2) true net power calculated using the Gaussian optics formula, (3) total corneal refractive power at 2.0 mm calculated by ray tracing on a ring and (4) as the average of the zone inside the ring, (5) total corneal refractive power at 3.0 mm on a ring and (6) as the average of the zone inside the ring, (7) the equivalent K reading at 3.0 mm and (8) at 4.5 mm. The IOL power was calculated using the Hoffer Q, Holladay 1, and SRK/T formulas. No statistically significant differences were observed between any corneal power measurements, including simulated K, in 41 consecutive patients. The latter showed slightly lower mean absolute errors with all 3 formulas (range 0.26 to 0.27 diopter [D]). The Scheimpflug camera gave the lowest median absolute errors with all formulas; that is, the 3.0 mm equivalent K reading with the Hoffer Q formula (0.18 D) and Holladay 1 formula (0.17 D) and the 2.0 mm total corneal refractive power ring with the SRK/T formula (0.18 D). Corneal power measurements provided by the Scheimpflug camera and Placido disk corneal topographer displayed comparable accuracy in IOL power calculation.Keywords
This publication has 24 references indexed in Scilit:
- Accuracy of corneal power measurements by a new Scheimpflug camera combined with Placido-disk corneal topography for intraocular lens power calculation in unoperated eyesJournal of Cataract & Refractive Surgery, 2012
- Accuracy of a dual Scheimpflug analyzer and a corneal topography system for intraocular lens power calculation in unoperated eyesJournal of Cataract & Refractive Surgery, 2011
- Repeatability and Reproducibility of Corneal Curvature Measurements Using the Pentacam and Keratron Topography SystemsJournal of Refractive Surgery, 2009
- Prediction of the effective postoperative (intraocular lens) anterior chamber depthJournal of Cataract & Refractive Surgery, 2006
- Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to HaigisGraefe's Archive for Clinical and Experimental Ophthalmology, 2000
- Corneal Geometry Reconstruction with the Keratron VideokeratographerOptometry and Vision Science, 1997
- Prospective evaluation of early visual and refractive effects with small clear corneal incision for cataract surgeryJournal of Cataract & Refractive Surgery, 1996
- Astigmatic stabilization of 3.0 mm temporal clear corneal cataract incisionsJournal of Cataract & Refractive Surgery, 1996
- Assessment of Radial Aspheres by the Arc-Step Algorithm as Implemented by the Keratron KeratoscopeAmerican Journal of Ophthalmology, 1995
- A three-part system for refining intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 1988