Sub‐synchronous torsional interaction with VSC‐HVDC affected by feed‐forward compensations in current controllers
Authors:
Open Access
- 19 January 2017
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2017 (13) , 2140-2145
Abstract
The sub‐synchronous torsional interaction (SSTI) behaviour between turbine‐generator units and the high‐voltage direct current (HVDC) systems has been a vital research content in power systems. In the past, the characteristics of SSTI with line‐commutated‐converter (LCC)‐HVDC have already been well studied. With the development of voltage source converter (VSC)‐based HVDC, some researchers have found that different control parameters of the converter have an impact on the electrical damping of the connected synchronous generator system. However, the existing results did not show the specific mechanism of SSTI. In this study, SSTI with VSC‐HVDC affected by voltage feed‐forward (VVF) compensations in the AC current controllers is investigated. The effects of the asymmetric VVF in both d ‐ and q ‐axes on electrical damping are paid special attention. First, a general output impedance model of VSC‐HVDC concentrated on AC current controllers is developed. Then the influence of compensation factor ( k d/q ) and filter bandwidth ( α f d/q ) on the bandwidth of the converter and the electrical damping is studied. Finally, an SSTI suppression scheme based on the former analysis is given. Simulation studies are carried out in PSCAD/EMTDC, and simulated results validate the analytical results and proposed suppression scheme.Keywords
This publication has 9 references indexed in Scilit:
- Modeling of DFIG-Based WTs for Small-Signal Stability Analysis in DVC Timescale in Power Electronized Power SystemsIEEE Transactions on Energy Conversion, 2017
- Small Signal Dynamics of DFIG-Based Wind Turbines During Riding Through Symmetrical Faults in Weak AC GridIEEE Transactions on Energy Conversion, 2017
- Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control TimescaleIEEE Transactions on Power Systems, 2017
- Modeling of Grid-Connected DFIG-Based Wind Turbines for DC-Link Voltage Stability AnalysisIEEE Transactions on Sustainable Energy, 2015
- A Simple Approach to Damp SSR in Series-Compensated Systems via Reshaping the Output Admittance of a Nearby VSC-Based SystemIEEE Transactions on Industrial Electronics, 2014
- Modeling and mitigation of harmonic resonance between wind turbines and the grid2011
- Voltage‐Sourced Converters in Power Systems2010
- Analysis of Subsynchronous Torsional Interaction With Power Electronic ConvertersIEEE Transactions on Power Systems, 2007
- First benchmark model for computer simulation of subsynchronous resonanceIEEE Transactions on Power Apparatus and Systems, 1977