Hammering Force during Cementless Total Hip Arthroplasty and Risk of Microfracture
- 1 May 2011
- journal article
- research article
- Published by SAGE Publications in HIP International
- Vol. 21 (3) , 330-335
Abstract
During cementless stem fixation, impaction of the stem is occasionally complicated by bony injuries. Small fractures not visible to the eye during surgery or on post-operative radiographs may remain undetected, and the incidence of such injuries may be underestimated. Employing the same techniques as those employed during total hip arthroplasty, we implanted cementless stems into artificial femora, with equivalent mechanical characteristics to living femora. The hammering force applied to the femur and the displacement of the stem and femur were measured using a load sensor and imaging, respectively. The von Mises stress generated in the femur during cementless stem press-fixation was also measured using finite element analysis. Average hammering force under these conditions (9.25 kN) was sufficient to cause damage to the artificial femur. The first two of eight hammer strikes caused most displacement of the stem. The von Mises stresses generated by the first and second hammer strikes were 31 and 68 MPa, respectively. Applying a high average hammering force to the stem after displacement has ceased probably contributes to the generation of intraoperative fractures during cementless stem fixation. Given that two strikes appeared to be sufficient, we believe that hammering force should be reduced to a micro-adjustment level after the second hit.Keywords
This publication has 10 references indexed in Scilit:
- In vivo evaluation of a vibration analysis technique for the per-operative monitoring of the fixation of hip prosthesesJournal of Orthopaedic Surgery and Research, 2009
- Epidemiology of periprosthetic femur fracture around a total hip arthroplastyInjury, 2007
- Assessments of different kinds of stems by experiments and FEM analysis: Appropriate stress distribution on a hip prosthesisClinical Biomechanics, 2006
- Assessment of the fixation stiffness of some femoral stems of different designsClinical Biomechanics, 2006
- Periprosthetic femoral fractures – a comparison between cemented and uncemented hemiarthroplastiesInjury, 2005
- Determination of orthotropic bone elastic constants using FEA and modal analysisJournal of Biomechanics, 2002
- Primary stability in cementless femoral stems: custom-made versus conventional femoral prosthesisClinical Biomechanics, 2002
- A Comparative Study of the Initial Stability of Cementless Hip ProsthesesClinical Orthopaedics and Related Research, 1989
- Femoral fracture during non-cemented total hip arthroplasty.Journal of Bone and Joint Surgery, 1989
- The Differentiation of Loose and Secure Femoral Implants in Total Hip Replacement Using a Vibrational Technique: An Anatomical and Pilot Clinical StudyProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 1989