RSRina Sakai

Rina Sakai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rina Sakai has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Kiyoshi Mabuchi

    Department of Medical Engineering and Technology, School of Allied Health Sciences, Kitasato University, 1-15-1 Kitasato, Minami Ku, Sagamihara, Kanagawa 252-0329, Japan

    7 shared publications
  • Moritoshi Itoman

    Kyushu Rosai Hospital, Kitakyushu City, Fukuoka - Japan

    7 shared publications
  • Kentaro Uchida

    Department of Orthopaedic Surgery, Kitasato University School of Medicine, 1-15-1 Minami-ku, Kitasato, Sagamihara 252-0374, Kanagawa, Japan

    5 shared publications
  • Masashi Takaso

    Department of Orthopaedic Surgery, School of Medicine, Kitasato University, Sagamihara City, Kanagawa - Japan

    4 shared publications
  • Takeaki Yamamoto

    Department of Orthopaedic Surgery, School of Medicine, Kitasato University, Sagamihara, Kanagawa, Japan

    4 shared publications
  • Katsufumi Uchiyama

    Department of Orthopaedic Surgery, School of Medicine, Kitasato University, Sagamihara City, Kanagawa - Japan

    3 shared publications

Latest Publications

  • Open Access

    Usefulness of Additional Sutures for Unstable Distal Clavicular Fractures: A Biomechanical Study

    by Rina Sakai, Akihiro Maruo, Terumasa Matsuura, Kazuhiro Yoshida, Tomomi Mizuhashi, Kugo Takeda, Masanobu Ujihira

    The establishment of ideal management for unstable distal clavicular fractures remains a subject of active discussion, and the topic of distal clavicular fragment management is rarely discussed. This study aimed to biomechanically investigate the effectiveness of adding sutures to plate fixation for Craig type V unstable distal clavicular fractures. Two types of clavicular models made of polyurethane foam conforming to ASTM F-1839-08 were prepared to replicate bone fragments of Craig type V fracture. A series of loading tests were conducted on models fixed with locking plates (LP Group), those fixed with double arm Scorpion NEO plates (SN Group), and those fixed with double arm plates and additional sutures (SF Group). SF Group exhibited significantly higher flexural rigidity in normal and poor bone qualities compared with LP Group, while no significant difference in torque rigidity was observed among the three groups in both bone qualities. The effect of additional sutures was not clear, although it would be beneficial if the double arm plate and bone fragments can be restored together. The double arms support the distal clavicle fragment to reintegrate fragments by pressing them from above and fixing them. In conclusion, the double arm plate was mechanically effective in fixing type V fractures in which distal bone fragments would separate in the vertical direction. (209 words)


  • Open Access

    Usefulness of a Metal Artifact Reduction Algorithm in Digital Tomosynthesis Using a Combination of Hybrid Generative Adversarial Networks

    by Tsutomu Gomi, Rina Sakai, Hidetake Hara, Yusuke Watanabe, Shinya Mizukami

    In this study, a novel combination of hybrid generative adversarial networks (GANs) comprising cycle-consistent GAN, pix2pix, and (mask pyramid network) MPN (CGpM-metal artifact reduction [MAR]), was developed using projection data to reduce metal artifacts and the radiation dose during digital tomosynthesis. The CGpM-MAR algorithm was compared with the conventional filtered back projection (FBP) without MAR, FBP with MAR, and convolutional neural network MAR. The MAR rates were compared using the artifact index (AI) and Gumbel distribution of the largest variation analysis using a prosthesis phantom at various radiation doses. The novel CGpM-MAR yielded an adequately effective overall performance in terms of AI. The resulting images yielded good results independently of the type of metal used in the prosthesis phantom (p < 0.05) and good artifact removal at 55% radiation-dose reduction. Furthermore, the CGpM-MAR represented the minimum in the model with the largest variation at 55% radiation-dose reduction. Regarding the AI and Gumbel distribution analysis, the novel CGpM-MAR yielded superior MAR when compared with the conventional reconstruction algorithms with and without MAR at 55% radiation-dose reduction and presented features most similar to the reference FBP. CGpM-MAR presents a promising method for metal artifact and radiation-dose reduction in clinical practice.


  • Open Access

    Influence of hooks and a lag screw on internal fixation plates for lateral malleolar fracture: a biomechanical and ergonomic study

    by Rina Sakai, Masataka Uchino, Terumasa Yoneo, Yasuaki Ohtaki, Hiroaki Minehara, Terumasa Matsuura, Tsutomu Gomi, Masanobu Ujihira

    For internal fixation of AO classification Type B lateral malleolar fracture, insertion of lag screws into the fracture plane and fixation with a one-third tubular plate as a neutralization plate are the standard treatment procedures. The one-third tubular plate is processed to a hook shape and hung on the distal end of the fibula. In this study, to compare the function of the hook and lag screws of a one-third tubular plate and LCP for osteosynthesis of lateral malleolar fracture, mechanical indices of internal fixation were compared among the one-third tubular plates with lag screws with and without the hook and a locking compression plate. As mechanical tests, a compression test was performed in which compression in the bone axis direction produced by supporting the body weight was simulated, and a torsion test was performed in which external rotation of the bone axis caused by plantar flexion of the ankle joint was simulated. Muscle strength during walking and the force and torque acting on the ankle and knee joints were determined using inverse dynamic analysis. Finite element analysis was performed to analyze the function of hooks and lag screws. The joint reaction force determined by inverse dynamic analysis was adopted as the loading condition of finite element analysis. A stiffness equivalent to that of healthy bone could be achieved by all three internal fixations. It was clarified that the presence of the hook does not make a difference in stiffness. Displacement of the one-third tubular plate was small regardless of the presence or absence of the hook compared with those of locking compression plates. The presence of the hook did not make any difference in stiffness, suggesting that active preparation of the hook is unnecessary. We also clarified that lag screws inhibit displacement.


  • Open Access

    Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses

    by Rina Sakai, Terumasa Matsuura, Kensei Tanaka, Kentaro Uchida, Masaki Nakao, Kiyoshi Mabuchi

    It is difficult to apply strong and stable internal fixation to a fracture of the distal end of the clavicle because it is unstable, the distal clavicle fragment is small, and the fractured region is near the acromioclavicular joint. In this study, to identify a superior internal fixation method for unstable distal clavicular fracture, we compared three types of internal fixation (tension band wiring, scorpion, and LCP clavicle hook plate). Firstly, loading tests were performed, in which fixations were evaluated using bending stiffness and torsional stiffness as indices, followed by finite element analysis to evaluate fixability using the stress and strain as indices. The bending and torsional stiffness were significantly higher in the artificial clavicles fixed with the two types of plate than in that fixed by tension band wiring (P<0.05). No marked stress concentration on the clavicle was noted in the scorpion because the arm plate did not interfere with the acromioclavicular joint, suggesting that favorable shoulder joint function can be achieved. The stability of fixation with the LCP clavicle hook plate and the scorpion was similar, and plate fixations were stronger than fixation by tension band wiring.


  • Open Access

    Correlation between the Bone Mineral Density and Stress on Femur around a Duetto SI Stem

    by Rina Sakai, Takeaki Yamamoto, Katsufumi Uchiyama, Kentaro Uchida, Masaki Nakao, Kiyoshi Mabuchi

    In cementless stem fixation, BMD reduction around the stem is of concern because it may cause loosening. This BMD reduction is assumed to be caused by stem implantation-induced alteration of the physiological feedback system, which may cause stress shielding and result in loosening, but the causal relationship has not been clarified. In this study, using a Duetto SI stem, we investigated the correlation between the postoperative BMD around the stem and stress. In patients who underwent their first THA at the orthopedic department of our university, the BMD was measured using DEXA, and FEA was performed with an equivalent time course. Time-course changes in the BMD, von Mises stress, and triaxial stress in Gruen zones 1 through 7 were calculated from those measured at 2 weeks and 5 months after surgery. The BMD and von Mises stress showed a bidirectional correlation when Gruen’s classification was plotted on the horizontal axis. An increase in stress loaded on bone was assumed to be a factor increasing the BMD. The Duetto SI stem was fixed on the distal side, suggesting its stable fixation. BMD measurement and FEA were useful for quantification of the bone dynamics around the stem from an early phase.

  • Hammering Sound Frequency Analysis and Prevention of Intraoperative Periprosthetic Fractures during Total Hip Arthroplasty

    by Rina Sakai, Aki Kikuchi, Towa Morita, Naonobu Takahira, Katsufumi Uchiyama, Takeaki Yamamoto, Mistutoshi Moriya, Kentaro Uchida, Kensuke Fukushima, Kensei Tanaka, et al.

    Adequate fixation at the time of cementless stem implantation depends on the operator's experience. An objective evaluation method to determine whether the stem has been appropriately implanted may be helpful. We studied the relationship between the hammering sound frequency during stem implantation and internal stress in a femoral model, and evaluated the possible usefulness of hammering sound frequency analysis for preventing intraoperative fracture. Three types of cementless stem (BiCONTACT®, SL-PLUS®, and AI-Hip®) were used. Surgeons performed stem insertion using a procedure similar to that employed in a routine operation. Stress was estimated by finite element analysis, the hammering force was measured, and frequency analysis of hammering sound data obtained using a microphone. Finite element analysis showed a decrease in the hammering sound frequency with an increase in the estimated maximum stress. When a decrease in frequency was observed, adequate hammering had occurred, and the continuation of hammering risked fracture. Based on the relationship between stress and frequency, the evaluation of changes in frequency may be useful for preventing the development of intraoperative fractures. Using our method, when a decrease in frequency is observed, the hammering force should be reduced. Hammering sound frequency analysis may allow the prediction of bone fractures that can be visually confirmed, and may be a useful objective evaluation method for the prevention of intraoperative periprosthetic fractures during stem insertion.


  • Hammering Force during Cementless Total Hip Arthroplasty and Risk of Microfracture

    by Rina Sakai, Akiko Takahashi, Naonobu Takahira, Katsufumi Uchiyama, Takeaki Yamamoto, Kentaro Uchida, Kensuke Fukushima, Mistutoshi Moriya, Masashi Takaso, Moritoshi Itoman, et al.

    During cementless stem fixation, impaction of the stem is occasionally complicated by bony injuries. Small fractures not visible to the eye during surgery or on post-operative radiographs may remain undetected, and the incidence of such injuries may be underestimated. Employing the same techniques as those employed during total hip arthroplasty, we implanted cementless stems into artificial femora, with equivalent mechanical characteristics to living femora. The hammering force applied to the femur and the displacement of the stem and femur were measured using a load sensor and imaging, respectively. The von Mises stress generated in the femur during cementless stem press-fixation was also measured using finite element analysis. Average hammering force under these conditions (9.25 kN) was sufficient to cause damage to the artificial femur. The first two of eight hammer strikes caused most displacement of the stem. The von Mises stresses generated by the first and second hammer strikes were 31 and 68 MPa, respectively. Applying a high average hammering force to the stem after displacement has ceased probably contributes to the generation of intraoperative fractures during cementless stem fixation. Given that two strikes appeared to be sufficient, we believe that hammering force should be reduced to a micro-adjustment level after the second hit.


  • Open Access

    Inference of hammering force during non-cemented total hip arthroplasty

    by Rina Sakai, Akiko Takahashi, Naonobu Takahira, Katsufumi Uchiyama, Takeaki Yamamoto, Kensuke Fukushima, Mistutoshi Moriya, Kentaro Uchida, Masashi Takaso, Moritoshi Itoman, et al.

  • Open Access

    Prediction of the fixation conditions of murine fracture fixation plates

    by Rina Sakai, Roland Steck, Gongfa Chen, Michael Schuetz, Naho Okuda, Hiroaki Minehara, Masaki Ueno, Kentaro Uchida, Masashi Takaso, Moritoshi Itoman, et al.

  • Open Access

    Simulation of the Effect of Flexible and Rigid Plate Designs on Murine Fracture Healing

    by Rina Sakai, Roland Steck, Masaki Ueno, Kentaro Uchida, Hiroaki Minehara, Kensei Tanaka, Masashi Takaso, Moritoshi Itoman, Kiyoshi Mabuchi, Michael Schuetz

    Although several histological studies in mice have examined healing of fractures secured with bone plates, no data are available at present on the mechanical response of fractured bone or callus tissue. Here, we simulated the healing response of fractures secured with rigid and flexible bone plate-designs. Using finite element methods, we simulated the maximum principal strain, stress, and strain energy density in the fractured region of mouse femurs under three loading conditions. In the rigid plate-design, the strain energy density increased when compression and bending were loaded and decreased when torsion was loaded. In the flexible plate-design, the strain energy density increased under all loading conditions. Since an increase in the strain energy density indicates an increase in mechanical stimulation, the simulation suggests that the flexible plate design may stimulate bone growth more than the rigid plate design. A favorable bone plate design must be stiff enough to avoid dislocation but flexible enough to provide mechanical stimulation.