Development of a static chamber system based on magnetic triggering mechanism for precise measurement of activated carbon radon adsorption rate
- 8 September 2026
- journal article
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (36) , 365003
Abstract
Accurately assessing the passive radon adsorption performance of porous materials under natural conditions is of vital importance for environmental radiation protection. Currently, the existing testing methods have obvious limitations: the active adsorption method is affected by forced airflow and it is difficult to extract the true physical adsorption parameters; while the traditional static chamber method faces the dual problems of gas mixture delay and mechanical operation interference. To address the aforementioned bottlenecks, this paper proposes a dual-cycle closed radon monitoring system based on a magnetic triggering mechanism. By placing the sample box with a magnetic control cover in the chamber in advance, the passive adsorption process of the dried coconut shell activated carbon can be triggered instantly without damaging the system’s sealing boundary. The experiment was conducted in two stages: Firstly, the baseline leakage rate of the system was calibrated by monitoring the decay of natural radon. Then, the adsorption process was remotely initiated by a magnetic trigger, and the entire process did not disrupt the sealed state. The full-time concentration data were nonlinearly fitted using a first-order kinetic model that included leakage and adsorption terms, resulting in an average natural leakage rate of (1.19 ± 0.09) × 10 −5 s −1 and a passive radon adsorption rate constant of (3.61 ± 0.20) × 10 −4 s −1 (dry coconut shell activated carbon). The entire adsorption process was driven solely by the natural concentration gradient, and the samples could be pre-stored in sealed containers for a long time before the test. Crucially, the measured adsorption rate is approximately 30 times greater than the baseline leakage, demonstrating the system’s ability to effectively decouple genuine adsorption kinetics from background errors. This low-disturbance paradigm enables reliable evaluation of porous materials for practical indoor radon mitigation.Keywords
Funding Information
- Hunan Provincial Natural Science Foundation Youth Project (2024JJ6096)
- Postgraduate Scientific Research Innovation Project of Hunan Province (CX20251739)
- Hunan Provincial Department of Education Excellent Young Researcher Project (24B0652)
- Project of Hunan Provincial Department of Education (23A0516)
This publication has 20 references indexed in Scilit:
- Suitability evaluation of measurement method for radon exhalation rate of porous medium containing radon adsorbing materialsJournal of Hazardous Materials, 2025
- Developing a radon monitor for simultaneous measurement of Rn-222 and Rn-220 with less influence of humidity based on electrostatic collection and CR-39 detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Radon dynamic adsorption coefficients of two activated charcoals at different temperatures in nitrogen environmentApplied Radiation and Isotopes, 2022
- Construction of a low-temperature activated carbon radon adsorption system using air coolerJournal of Radioanalytical and Nuclear Chemistry, 2022
- The temperature dependence of adsorption coefficients of 222 Rn on activated charcoal: an experimental studyApplied Radiation and Isotopes, 2017
- Evaluation of radon adsorption characteristics of a coconut shell-based activated charcoal system for radon and thoron removal applicationsJournal of Environmental Radioactivity, 2015
- Passive, integrated measurement of radon using 5A synthetic zeolite and blue silica gelApplied Radiation and Isotopes, 2010
- A short-time method to measure the radon potential of porous materialsApplied Radiation and Isotopes, 2009
- Simultaneous determination of 222Rn and 220Rn exhalation rates from building materials used in Central Italy with accumulation chambers and a continuous solid state alpha detector: Influence of particle size, humidity and precursors concentrationApplied Radiation and Isotopes, 2006
- The influence of environmental parameters in electrostatic cell radon monitor responseApplied Radiation and Isotopes, 2004