TWENTY-FIVE-GAUGE VITRECTOMY FOR THE REMOVAL OF 5000 CENTISTOKES SILICONE OIL
Authors:
- Denis JusufbegovicDJDenis Jusufbegovic
- Jonathan D. GambrellJGJonathan D. Gambrell
- Yoreh BarakYBYoreh Barak
- Shlomit SchaalSSShlomit Schaal
- 1 October 2013
- journal article
- research article
- Published by Wolters Kluwer Health in Retina
- Vol. 33 (9) , 1938-1942
Abstract
To compare the safety and efficacy of removing 5000 centistokes silicone oil between 20-gauge and 25-gauge vitrectomy technique. Prospective case series of 34 consecutive patients undergoing 5000 centistokes silicone oil removal using 20-gauge or 25-gauge cannulas. The main outcome measures were the safety and efficacy of silicone oil removal. The safety was evaluated by recording intraoperative and postoperative complication rates, including bleeding, recurrence of retinal detachment, hypotony, choroidal detachment, corneal edema, endophthalmitis, vitreous hemorrhage, conjunctival injection, and subconjunctival hemorrhage. The efficacy was judged by the ability to attain the complete removal of silicone oil and the total surgical time to complete the procedure. Sixteen patients underwent 20-gauge vitrectomy for the removal of 5000 centistokes silicone oil between January 2008 and January 2010, and 18 patients underwent 25-gauge vitrectomy for the removal of 5000 centistokes silicone oil from January 2010 to August 2012. Silicone oil was successfully removed completely in all cases. Using 25-gauge vitrectomy to remove silicone oil was significantly more time efficient with the mean total surgical time of 25 ± 6 minutes compared with 42 ± 10 minutes in 20-gauge vitrectomy group (P < 0.05). There were no differences in the intraoperative or postoperative complication rates between the two groups. None of the patients developed postoperative recurrence of retinal detachment, hypotony, choroidal detachment, corneal edema, endophthalmitis, or vitreous hemorrhage. Twenty-five-gauge silicone oil removal is safe and effective. Surgical time is significantly reduced using sutureless 25-gauge sclerotomies. This may translate to cost reduction by decreasing time spent in the operating room.Keywords
This publication has 29 references indexed in Scilit:
- Outcomes and Complications of 25-Gauge Transconjunctival Sutureless Vitrectomy for Proliferative Diabetic RetinopathyOphthalmologica, 2011
- RETROSPECTIVE COMPARISON OF 25-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY TO 20-GAUGE VITRECTOMY FOR THE REPAIR OF PSEUDOPHAKIC PRIMARY INFERIOR RHEGMATOGENOUS RETINAL DETACHMENTRetina, 2010
- THE SAFETY AND EFFICACY OF PASSIVE REMOVAL OF SILICONE OIL WITH 23-GAUGE TRANSCONJUNCTIVAL SUTURELESS SYSTEMRetina, 2010
- Passive removal of silicone oil with a 25-gauge sutureless systemJapanese Journal of Ophthalmology, 2008
- REMOVAL OF SILICONE OIL WITH 25-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY SYSTEMRetina, 2007
- SILICONE OIL REMOVAL USING VITRECTOMY MACHINE:Retina, 2001
- Outcome after silicone oil removalBritish Journal of Ophthalmology, 2001
- A SIMPLE AND INEXPENSIVE SYSTEM FOR THE REMOVAL OF SILICONE OIL THROUGH A 20-GAUGE OPENINGRetina, 1995
- Silicone oil with high specific gravity for intraocular use.British Journal of Ophthalmology, 1987
- A SIMPLIFIED TECHNIQUE FOR THE REMOVAL OF LIQUID SILICONE FROM VITRECTOMIZED EYESRetina, 1985