Catheter Ablation of Scar-Related Ventricular Tachycardia in Patients with Electrical Storm Using Remote Magnetic Catheter Navigation
Authors:
- Arash AryaAAArash Arya
- Andreas BollmannABAndreas Bollmann
- Gerhard HindricksGHGerhard Hindricks
- 17 August 2010
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (11) , 1312-1318
Abstract
Background: A remote magnetic navigation system (MNS) has been used for ablation of ventricular arrhythmias. However, irrigated tip catheter has not been evaluated in large series of patients. Objective: To evaluate acute and long‐term efficiency of the newly available irrigated tip magnetic catheter for radiofrequency (RF) ablation of scar‐related ventricular tachycardia (VT) in patients with ischemic heart disease. Methods: Between January 2008 and October 2009, a total of 30 consecutive patients with ischemic heart disease (26 men, age 70.1 ± 8.7 years, left ventricular ejection fraction: 30 ± 9%) and electrical storm due to monomorphic VT underwent RF ablation using a remote MNS and a magnetic irrigated tip catheter. Results: Acute success was defined as noninducibility of any monomorphic VT during programmed right and left ventricular stimulation, and obtained in 24 (80%) patients. A total of 1–6 VTs (mean 2.3 ± 1.2, 394 ± 108 ms, 210–660 ms) were inducible during each procedure. The duration of RF energy application was 41.2 ± 23.3 minutes, with total procedure and fluoroscopy times of 158 ± 47 minutes and 9.8 ± 5.3 minutes, respectively. No acute complications were observed during the procedures. During mean follow‐up of 7.8 months, 21 patients (70%) had no recurrence of VT and received no implantable cardioverter defibrillator therapy. Among patients who were noninducible during programmed right ventricular stimulation (n = 25), ≥1 monomorphic VT was inducible during programmed left ventricular stimulation in four (16%) that was ablated successfully in three of them. Conclusions: Irrigated ablation of scar‐related VT using remote MNS is an effective modality for management of the monomorphic VT in patients with ischemic cardiomyopathy with minimal radiation exposure. Programmed left (in addition to right) ventricular stimulation might be necessary to assess acute outcome of the ablation procedure. (PACE 2010; 1312–1318)Keywords
This publication has 20 references indexed in Scilit:
- Catheter Ablation of Recurrent Scar‐Related Ventricular Tachycardia Using Electroanatomical Mapping and Irrigated Ablation Technology: Results of the Prospective Multicenter Euro‐VT‐StudyJournal of Cardiovascular Electrophysiology, 2009
- Initial Clinical Experience with the New Irrigated Tip Magnetic Catheter for Ablation of Scar‐Related Sustained Ventricular Tachycardia: A Small Case SeriesJournal of Cardiovascular Electrophysiology, 2009
- Initial Clinical Experience with a Remote Magnetic Catheter Navigation System for Ablation of Cavotricuspid Isthmus‐Dependent Right Atrial FlutterPacing and Clinical Electrophysiology, 2008
- Catheter Ablation for the Treatment of Electrical Storm in Patients With Implantable Cardioverter-DefibrillatorsCirculation, 2008
- Initial Experience with a Novel Remote‐Guided Magnetic Catheter Navigation System for Left Ventricular Scar Mapping and Ablation in a Porcine Model of Healed Myocardial InfarctionJournal of Cardiovascular Electrophysiology, 2007
- Remote Magnetic Navigation to Guide Endocardial and Epicardial Catheter Mapping of Scar-Related Ventricular TachycardiaCirculation, 2007
- Remote Magnetic Navigation to Map and Ablate Left Coronary Cusp Ventricular TachycardiaJournal of Cardiovascular Electrophysiology, 2006
- Robotic Magnetic Navigation for Atrial Fibrillation AblationJACC, 2006
- Remote magnetic navigation for mapping and ablating right ventricular outflow tract tachycardiaHeart Rhythm, 2006
- Prevalence and Predictors of Electrical Storm in Patients With Implantable Cardioverter-DefibrillatorThe American Journal of Cardiology, 2006