Arash Arya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arash Arya has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
Gerhard Hindricks
Heart Center Leipzig, Department of Electrophysiology, Leipzig, Germany
24 shared publicationsChristopher Piorkowski
Department of Electrophysiology, University Leipzig-Heart Center, Struempellstrasse 39, Leipzig, Germany
17 shared publicationsAndreas Bollmann
Heart Center Leipzig, Department of Electrophysiology, Leipzig, Germany
16 shared publicationsPhilipp Sommer
Heart Center Leipzig, Department of Electrophysiology, Leipzig, Germany
12 shared publications- Majid Haghjoo
Department of Electrophysiology Rajaie Cardiovascular Medical and Research Center, Iran university of medical sciences Tehran Iran
9 shared publications - Gerhard Hindricks
Bordeaux, France; Department of Electrophysiology - University of Leipzig - Heart Center, Leipzig, Germany
8 shared publications
Latest Publications
- 9 January 2020
- Published by Walter de Gruyter GmbH in Diagnosis
- Vol. 8 (3) , 295-303
Atrial fibrillation: is there a role for cardiac troponin?
Atrial fibrillation (AF) is the most common sustained arrhythmia, and its prevalence rate is expected to be doubled over the next decades. Despite the wide use of biomarkers in the management of different cardiac diseases such as myocardial infarction and heart failure, utilization of biomarkers in AF management is not routinely recommended by current guidelines. There is also growing evidence that higher levels of cardiac-specific troponin, as an intracellular protein involved in cardiomyocyte contraction, may be associated with the risk of incident and recurrent AF and its complications. In the present paper, we review the association between troponin and AF and propose clinical suggestions for use of troponin in the management of AF patients.
- 9 January 2020
- Published by Walter de Gruyter GmbH in Diagnosis
- Vol. 8 (3) , 295-303
Atrial fibrillation: is there a role for cardiac troponin?
Atrial fibrillation (AF) is the most common sustained arrhythmia, and its prevalence rate is expected to be doubled over the next decades. Despite the wide use of biomarkers in the management of different cardiac diseases such as myocardial infarction and heart failure, utilization of biomarkers in AF management is not routinely recommended by current guidelines. There is also growing evidence that higher levels of cardiac-specific troponin, as an intracellular protein involved in cardiomyocyte contraction, may be associated with the risk of incident and recurrent AF and its complications. In the present paper, we review the association between troponin and AF and propose clinical suggestions for use of troponin in the management of AF patients.
- 1 December 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (12) , 1812-1819
Predictors of ventricular arrhythmia after left ventricular assist device implantation: A large single-center observational study
- 1 December 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (12) , 1812-1819
Predictors of ventricular arrhythmia after left ventricular assist device implantation: A large single-center observational study
- 1 November 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (11) , 1766-1775
Individually tailored vs. standardized substrate modification during radiofrequency catheter ablation for atrial fibrillation: a randomized study
This randomized single-centre study sought to compare the efficacy and safety of pulmonary vein isolation (PVI) plus voltage-guided ablation vs. PVI with or without linear ablation depending on the type of atrial fibrillation (AF). Overall, 124 ablation-naive patients with paroxysmal or persistent AF were randomized to PVI with (persistent AF) or without (paroxysmal AF) additional linear ablation (control group) vs. PVI plus ablation of low-voltage areas (LVAs) irrespective of AF type. Bipolar voltage mapping was performed during stable sinus rhythm. An LVA consisted of ≥ 3 adjacent mapping points that each had a peak-to-peak amplitude ≤0.5 mV. After a mean follow-up of 12 ± 3 months, significantly more patients in the LVA ablation group were free from atrial arrhythmia recurrence >30 s off antiarrhythmic drugs (AADs) after a single procedure (primary endpoint) compared with control group patients [40/59 (68%) vs. 25/59 (42%), log-rank P = 0.003]. Arrhythmia-free survival on or off AADs was found in 33/59 control group patients (56%) and in 41/59 LVA ablation group patients (70%) (adjusted log-rank P = 0.10). During the 7 day Holter monitoring period at 12 months, significantly more patients in the LVA ablation group were free from arrhythmia recurrence on or off AADs [45/50 (90%) vs. 33/46 (72%), P = 0.04]. No between-group differences were observed regarding procedure duration, fluoroscopy time, and major complications. In this single-centre study, individually tailored substrate modification guided by voltage mapping was associated with a significantly higher arrhythmia-free survival rate compared with a conventional approach applying linear ablation according to AF type.
- 1 November 2017
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 20 (11) , 1766-1775
Individually tailored vs. standardized substrate modification during radiofrequency catheter ablation for atrial fibrillation: a randomized study
This randomized single-centre study sought to compare the efficacy and safety of pulmonary vein isolation (PVI) plus voltage-guided ablation vs. PVI with or without linear ablation depending on the type of atrial fibrillation (AF). Overall, 124 ablation-naive patients with paroxysmal or persistent AF were randomized to PVI with (persistent AF) or without (paroxysmal AF) additional linear ablation (control group) vs. PVI plus ablation of low-voltage areas (LVAs) irrespective of AF type. Bipolar voltage mapping was performed during stable sinus rhythm. An LVA consisted of ≥ 3 adjacent mapping points that each had a peak-to-peak amplitude ≤0.5 mV. After a mean follow-up of 12 ± 3 months, significantly more patients in the LVA ablation group were free from atrial arrhythmia recurrence >30 s off antiarrhythmic drugs (AADs) after a single procedure (primary endpoint) compared with control group patients [40/59 (68%) vs. 25/59 (42%), log-rank P = 0.003]. Arrhythmia-free survival on or off AADs was found in 33/59 control group patients (56%) and in 41/59 LVA ablation group patients (70%) (adjusted log-rank P = 0.10). During the 7 day Holter monitoring period at 12 months, significantly more patients in the LVA ablation group were free from arrhythmia recurrence on or off AADs [45/50 (90%) vs. 33/46 (72%), P = 0.04]. No between-group differences were observed regarding procedure duration, fluoroscopy time, and major complications. In this single-centre study, individually tailored substrate modification guided by voltage mapping was associated with a significantly higher arrhythmia-free survival rate compared with a conventional approach applying linear ablation according to AF type.
- 1 August 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (8) , S114
Catheter Ablation for Recurrent Ventricular Tachycardia After Implantation of a Left Ventricular Assist Device: A Interdisciplinary Approach
- 1 August 2016
- Published by Elsevier in Journal of Cardiac Failure
- Vol. 22 (8) , S114
Catheter Ablation for Recurrent Ventricular Tachycardia After Implantation of a Left Ventricular Assist Device: A Interdisciplinary Approach
- 1 July 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (7) , 1534-1540
Differentiating the origin of outflow tract ventricular arrhythmia using a simple, novel approach
- 1 July 2015
- Published by Elsevier in Heart Rhythm
- Vol. 12 (7) , 1534-1540
Differentiating the origin of outflow tract ventricular arrhythmia using a simple, novel approach
- Open Access
- 21 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (2) , 232-238
Efficacy and safety of remote magnetic catheter navigation vs. manual steerable sheath-guided ablation for catheter ablation of atrial fibrillation: a case-control study
Data comparing remote magnetic catheter navigation (RMN) to manual catheter navigation (MCN) using steerable sheath for ablation of atrial fibrillation (AF) is lacking. The aim of the present case–control study was to seek AF recurrence data after AF ablation using RMN in comparison to MCN using steerable sheath in patients with either paroxysmal or persistent AF. This study comprised 140 patients with AF (50% paroxysmal). Seventy were ablated utilizing RMN and 70 with MCN. Primary endpoint was defined as the time to first recurrence after index procedure. After 28.8 ± 18.9 months of follow-up, more patients in the MCN group using steerable sheath remained free of recurrence compared with RMN group [(59.1 vs. 40%, respectively, P = 0.031), in patients with persistent AF P = 0.057, while in patients with paroxysmal AF, P = 0.18]. Index procedure time (223.6 ± 44.2 vs. 170.8 ± 51.8 min, P < 0.001) and radiofrequency application time (75.4 ± 20.9 vs. 56.6 ± 24.9 min, P < 0.001) were longer in the RMN group; however, the respective total fluoroscopy time (13.7 ± 7.8 vs. 36.6 ± 12.7 min, P < 0.001) was significantly shorter. In multivariable Cox-regression analysis, RMN was the only factor independently associated with shorter time to first recurrence during follow-up (P = 0.048). Complication rate did not differ significantly between groups (P = 0.056), although the incidence of significant pericardial effusion was higher in the MCN group (3 cases vs. 0 in RMN group). Although in patients with persistent AF, the recurrence rate is higher in RMN group, the outcome is comparable between RMN and MCN groups in patients with paroxysmal AF. A multicentre prospective randomized study is warranted to clarify this issue.
- 21 October 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 17 (2) , 232-238
Open AccessEfficacy and safety of remote magnetic catheter navigation vs. manual steerable sheath-guided ablation for catheter ablation of atrial fibrillation: a case-control study
Data comparing remote magnetic catheter navigation (RMN) to manual catheter navigation (MCN) using steerable sheath for ablation of atrial fibrillation (AF) is lacking. The aim of the present case–control study was to seek AF recurrence data after AF ablation using RMN in comparison to MCN using steerable sheath in patients with either paroxysmal or persistent AF. This study comprised 140 patients with AF (50% paroxysmal). Seventy were ablated utilizing RMN and 70 with MCN. Primary endpoint was defined as the time to first recurrence after index procedure. After 28.8 ± 18.9 months of follow-up, more patients in the MCN group using steerable sheath remained free of recurrence compared with RMN group [(59.1 vs. 40%, respectively, P = 0.031), in patients with persistent AF P = 0.057, while in patients with paroxysmal AF, P = 0.18]. Index procedure time (223.6 ± 44.2 vs. 170.8 ± 51.8 min, P < 0.001) and radiofrequency application time (75.4 ± 20.9 vs. 56.6 ± 24.9 min, P < 0.001) were longer in the RMN group; however, the respective total fluoroscopy time (13.7 ± 7.8 vs. 36.6 ± 12.7 min, P < 0.001) was significantly shorter. In multivariable Cox-regression analysis, RMN was the only factor independently associated with shorter time to first recurrence during follow-up (P = 0.048). Complication rate did not differ significantly between groups (P = 0.056), although the incidence of significant pericardial effusion was higher in the MCN group (3 cases vs. 0 in RMN group). Although in patients with persistent AF, the recurrence rate is higher in RMN group, the outcome is comparable between RMN and MCN groups in patients with paroxysmal AF. A multicentre prospective randomized study is warranted to clarify this issue.
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study