Feasibility study of the positronium imaging with the J-PET tomograph
Top Cited Papers
Open Access
- 1 March 2019
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (5) , 055017
Abstract
A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.Keywords
All Related Versions
Funding Information
- Austrian Science Fund (FWF-P26783)
- Ministry for Science and Higher Education (6673/IA/SP/2016, 7150/E-338/M/2017, 7150/E-338/M/2018, 7150/E-338/SPUB/2017/1)
- Fundacja na rzecz Nauki Polskiej (MPD, TEAM/2017-4/39)
- Narodowe Centrum Nauki (2016/21/B/ST2/01222, 2017/25/N/NZ1/00861)
- The Polish National Center for Research and Development (INNOTECH-K1/IN1/64/159174/NCBR/12)
This publication has 76 references indexed in Scilit:
- A practical method for depth of interaction determination in monolithic scintillator PET detectorsPhysics in Medicine & Biology, 2011
- Incorporation of the Magnetic Quenching Effect into the Blob Model of Ps Formation. Finite Sized Ps in a Potential WellMaterials Science Forum, 2010
- LaBr3:Ce and SiPMs for time-of-flight PET: achieving 100 ps coincidence resolving timePhysics in Medicine & Biology, 2010
- Performance of three-photon PET imaging: Monte Carlo simulationsPhysics in Medicine & Biology, 2005
- Precision measurement of orthopositronium decay rate using SiO2 powderPhysics Letters B, 2003
- Application of positron annihilation lifetime spectroscopy in studies of crystallization processesPhysical Chemistry Chemical Physics, 2003
- New precision measurement of the decay rate of singlet positroniumPhysical Review Letters, 1994
- Hopping Conductivity in Ordered and Disordered Systems (III)Physica Status Solidi (b), 1982
- Studies of molecular association in biological systems by positron annihilation techniquesJournal of the American Chemical Society, 1977
- Thermalization of Positrons in MetalsPhysical Review B, 1953