Daria Kisielewska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daria Kisielewska has a total of 247 co-authors. Here are the top co-authors by number of shared publications:
- Eryk Czerwinski
Jagiellonian University
20 shared publications - Pawel Moskal
Jagiellonian University
20 shared publications - Wojciech Krzemien
National Center for Nuclear Research (NCBJ)
19 shared publications - Magdalena Skurzok
Jagiellonian University
17 shared publications - Marek Gorgol
Institute of Physics, Maria Curie-Sklodowska University, pl. M. Curie-Sklodowskiej 1, 20-031 Lublin, Poland
17 shared publications - Roman Y. Shopa
National Centre for Nuclear Research
16 shared publications
Latest Publications
- Open Access
- 1 August 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1008, 165452
The J-PET detector—a tool for precision studies of ortho-positronium decays
- 1 August 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1008, 165452
Open AccessThe J-PET detector—a tool for precision studies of ortho-positronium decays
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Synchronization and Calibration of the 24-Modules J-PET Prototype With 300-mm Axial Field of View
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 ± 9 ps. This value can be translated to the position reconstruction accuracy σ(Δ) = 18 mm which is fairly position-independent Keywords: positron emission tomography, plastic scintillators, J-PET.
- 1 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
Synchronization and Calibration of the 24-Modules J-PET Prototype With 300-mm Axial Field of View
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 ± 9 ps. This value can be translated to the position reconstruction accuracy σ(Δ) = 18 mm which is fairly position-independent Keywords: positron emission tomography, plastic scintillators, J-PET.
- Top Cited PapersOpen Access
- 1 March 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (5) , 055017
Feasibility study of the positronium imaging with the J-PET tomograph
A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
- 1 March 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (5) , 055017
Top Cited PapersOpen AccessFeasibility study of the positronium imaging with the J-PET tomograph
A detection system of the conventional PET tomograph is set-up to record data from [Formula: see text] annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of ∼40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
- Open Access
- 1 February 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 199, 03006
Discrete symmetries studies at KLOE-2
The KLOE and KLOE-2 experiments at the Laboratori Nazionali di Frascati (Italy) collected almost 8 fb−1 of integrated luminosity at the energy equal to the mass of ϕ meson. The excellent time resolution of the electromagnetic calorimeter and the very good accuracy on both momentum and vertex reconstruction of the tracking system allow to study discrete symmetries to the utmost precision as well as light meson spectroscopy, dark forces searches, hadronic cross-section measurements and studies of γγ-physics. CPT symmetry test with the lepton charge asymmetry measured in KS semileptonic decays with 1.7 fb−1 of KLOE data, tests of time reversal and CPT in transitions in $\phi \to {K_S}{K_L} \to \pi ev,\,3{\pi ^0}(2{\pi ^0})$ decays with newly acquired data with the KLOE-2 detector will be presented and discussed.- 1 February 2019
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 199, 03006
Open AccessDiscrete symmetries studies at KLOE-2
The KLOE and KLOE-2 experiments at the Laboratori Nazionali di Frascati (Italy) collected almost 8 fb−1 of integrated luminosity at the energy equal to the mass of ϕ meson. The excellent time resolution of the electromagnetic calorimeter and the very good accuracy on both momentum and vertex reconstruction of the tracking system allow to study discrete symmetries to the utmost precision as well as light meson spectroscopy, dark forces searches, hadronic cross-section measurements and studies of γγ-physics. CPT symmetry test with the lepton charge asymmetry measured in KS semileptonic decays with 1.7 fb−1 of KLOE data, tests of time reversal and CPT in transitions in $\phi \to {K_S}{K_L} \to \pi ev,\,3{\pi ^0}(2{\pi ^0})$ decays with newly acquired data with the KLOE-2 detector will be presented and discussed. - Open Access
- 12 December 2018
- Published by Hindawi Limited in Advances in High Energy Physics
- Vol. 2018, 1-10
Feasibility Study of the Time Reversal Symmetry Tests in Decay of Metastable Positronium Atoms with the J-PET Detector
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of violation in nonvanishing angular correlations of final state observables in the decay of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of -violation sensitive observables.- 12 December 2018
- Published by Hindawi Limited in Advances in High Energy Physics
- Vol. 2018, 1-10
Open AccessFeasibility Study of the Time Reversal Symmetry Tests in Decay of Metastable Positronium Atoms with the J-PET Detector
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of violation in nonvanishing angular correlations of final state observables in the decay of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of -violation sensitive observables. - Open Access
- 24 November 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (11) , 1-9
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
J-PET is a detector optimized for registration of photons from the electron–positron annihilation via plastic scintillators where photons interact pr
- 24 November 2018
- Published by Springer Nature in The European Physical Journal C
- Vol. 78 (11) , 1-9
Open AccessFeasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
J-PET is a detector optimized for registration of photons from the electron–positron annihilation via plastic scintillators where photons interact pr
- Open Access
- 19 November 2018
- Published by Springer Nature in Hyperfine Interactions
- Vol. 239 (1) , 56
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
- 19 November 2018
- Published by Springer Nature in Hyperfine Interactions
- Vol. 239 (1) , 56
Open AccessA feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
- Open Access
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (11) , 2526-2535
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
- 1 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (11) , 2526-2535
Open AccessEvaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA SoC Devices
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
- Open Access
- 26 September 2018
- Published by Springer Nature in Hyperfine Interactions
- Vol. 239 (1) , 40
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
- 26 September 2018
- Published by Springer Nature in Hyperfine Interactions
- Vol. 239 (1) , 40
Open AccessCommissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
- Open Access
- 5 September 2018
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2018 (9) , 21
Measurement of the charge asymmetry for the KS → πeν decay and test of CPT symmetry with the KLOE detector
Using 1.63 fb−1 of integrated luminosity collected by the KLOE experiment about 7 × 104 K S → π ± e ∓ ν decays have been reconstructed. The measured value of the charge asymmetry for this decay is A S = (−4.9 ± 5.7stat ± 2.6syst) × 10−3, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives A S = (−3.8 ± 5.0stat ± 2.6syst) × 10−3 and, together with the asymmetry of the K L semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.
- 5 September 2018
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2018 (9) , 21
Open AccessMeasurement of the charge asymmetry for the KS → πeν decay and test of CPT symmetry with the KLOE detector
Using 1.63 fb−1 of integrated luminosity collected by the KLOE experiment about 7 × 104 K S → π ± e ∓ ν decays have been reconstructed. The measured value of the charge asymmetry for this decay is A S = (−4.9 ± 5.7stat ± 2.6syst) × 10−3, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives A S = (−3.8 ± 5.0stat ± 2.6syst) × 10−3 and, together with the asymmetry of the K L semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.