Abstract
The double beam system is a precast concrete moment-resisting frame system in which precast beam elements to support the floor slab pass alongside the column, rather than being directly connected to it. The precast beams are integrated with the column via the cast-in-place concrete joints and topping reinforced with on-site emulative reinforcement. In this study, the seismic performance of the double beam-to-column connections, emulating cast-in-place construction, was experimentally and analytically investigated. Cyclic tests showed that the double beam connections exhibited robust stiffness (prior to yielding) and strength, and maintained excellent deformation capacity, achieving lateral drift ratios exceeding 5 % with post-peak gradual strength degradation. However, the joints between the precast beam and column elements experienced severe concrete damage, leading to pronounced pinching in the cyclic curves and a substantial reduction in energy dissipation capacity. The double beam connections satisfied the strength and deformability requirements of ACI 374.1-05 but did not meet the criteria for energy dissipation and unloading/reloading stiffness under cyclic hysteretic behavior at a drift ratio of 3.5 %. The transfer of moments from the precast beams to the column through the cast-in-place joints with emulative reinforcement was further investigated using finite element analysis.

This publication has 6 references indexed in Scilit: