SLSeung-Jae Lee

Seung-Jae Lee

*This is an algorithmically generated author record based on publicly available information.

Seung-Jae Lee has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Shear strength of dapped ends for precast hollow composite beams

    by Seung-Jae Lee, Tae-Sung Eom, Jai-Chul Chung, Sung-Hwan Youn, Kyu-Rhee Kim

    This study experimentally and numerically investigates the shear strength of dapped ends used in precast hollow composite (PHC) beams developed for large-scale industrial facilities. Engineered to enhance structural performance through composite action and minimize self-weight, the PHC beam is an innovative precast member that features an H-shaped steel core encased by reinforced (and prestressed) concrete with a void formed around the steel core. Specifically, this study proposes structural details for the composite dapped end of PHC beams to facilitate mounting on column corbels or main girders and evaluates their shear capacity through experiments and numerical analysis. The experiments demonstrated that under ultimate loading, various steel and reinforcement components—including the steel web, hanger plate, and hanger and diagonal reinforcing bars—all reached their yield strengths, allowing their capacities to be fully mobilized. Based on the experimental observations, the shear strength of the composite dapped ends was determined by summing the individual strength contributions of these components. The calculated strengths showed excellent agreement with the peak loads obtained from the experiments. Finally, the shear transfer mechanism of each component within the composite dapped ends was further elucidated and validated through finite element analysis.

  • Open Access

    Seismic Performance of Precast Concrete Rocking Walls Post-Tensioned with Distributed 600 MPa Steel Bars

    by Tae-Sung Eom, Seung-Jae Lee, Hui Do Kim, Su-Min Kang, Seung-Il Kim

    In this study, the seismic and self-centering behavior of unbonded post-tensioned precast concrete rocking walls (PT walls) under cyclic lateral loading was investigated. Unlike conventional PT walls utilizing high-strength strands concentrated near the center of the wall section, this system utilizes ordinary 600 MPa grade steel bars distributed across the wall section to improve constructability and cost-efficiency, targeting applications in low- to medium-rise buildings. Three isolated and two coupled wall specimens were tested under cyclic loading. The tests revealed that the hysteretic behavior of the isolated walls exhibited pronounced pinching and near-zero energy dissipation, marking a distinct departure from the typical self-centering behavior of conventional PT walls; despite localized concrete crushing and cover spalling at the wall toes in the early loading stages, the structural integrity remained stable up to a drift ratio of 6%, with minimal strength degradation. In contrast, the coupled wall specimens exhibited cyclic responses resembling the typical self-centering behavior. However, since damage continuously accumulated in the coupling beams from the early loading stages, subsequent post-yield strength degradation became rapid and significant, ultimately reducing the overall deformation capacity. A rocking model incorporating structural compatibility constraints was proposed to calculate the strength and deformation at the first yield and ultimate states, while accounting for the pinching observed in the post-yield cyclic behavior.

  • Open Access

    Cyclic testing of wall spandrels with prefabricated reinforcement details

    by Yong Won Chung, Seung-Jae Lee, Tae-Sung Eom, Su-Min Kang, Hong-Gun Park, Seung Jun Lee, Seung-Il Kim

    The wall-spandrel structural system is a common lateral force-resisting system in high-rise residential buildings in Korea. In this system, ductile behavior under seismic loading can be achieved by designing the spandrels to be weaker than the connecting walls. Although proper seismic detailing is critical, reinforcement detailing for deep, narrow wall spandrels can present challenges to constructability. Thus, this study proposes prefabricated reinforcement details for wall spandrels to facilitate on-site construction and experimentally evaluates the seismic performance. Cyclic tests were performed on seven wall spandrels with prefabricated or conventional reinforcement. The results showed that the wall spandrels with the prefabricated reinforcement exhibited strength and stiffness comparable to those with conventional reinforcement. However, due to premature concrete failure and reinforcement buckling/rupture in the minimally reinforced zone, their deformation capacities decreased to drift levels of 2 ~ 3%. The cyclic curves were significantly pinched, due to the small aspect ratios of 1.33 and 1.78, leading to limited hysteretic energy dissipation. The flexural and shear strengths of the wall spandrels were compared with the nominal strengths calculated according to conventional design theory. In addition, the effective stiffness prior to yielding and the deformation capacity, obtained from the experiments, were compared with the modeling parameters of coupling beams specified in existing seismic guidelines.

  • Open Access

    Cyclic tests of precast concrete double beam-to-column connections with emulative joint details

    by Seung-Jae Lee, Tae-Sung Eom, Su-Min Kang

    The double beam system is a precast concrete moment-resisting frame system in which precast beam elements to support the floor slab pass alongside the column, rather than being directly connected to it. The precast beams are integrated with the column via the cast-in-place concrete joints and topping reinforced with on-site emulative reinforcement. In this study, the seismic performance of the double beam-to-column connections, emulating cast-in-place construction, was experimentally and analytically investigated. Cyclic tests showed that the double beam connections exhibited robust stiffness (prior to yielding) and strength, and maintained excellent deformation capacity, achieving lateral drift ratios exceeding 5 % with post-peak gradual strength degradation. However, the joints between the precast beam and column elements experienced severe concrete damage, leading to pronounced pinching in the cyclic curves and a substantial reduction in energy dissipation capacity. The double beam connections satisfied the strength and deformability requirements of ACI 374.1-05 but did not meet the criteria for energy dissipation and unloading/reloading stiffness under cyclic hysteretic behavior at a drift ratio of 3.5 %. The transfer of moments from the precast beams to the column through the cast-in-place joints with emulative reinforcement was further investigated using finite element analysis.