Abstract
In radiation therapy with orthovoltage units, the tube design has a crucial effect on its dosimetric features. In this study, the effect of anode angle on photon beam spectra, depth dose and photon fluence per initial electron was studied for a commercial orthovoltage unit of X-RAD320 biological irradiator. The MCNPX MC code was used for modeling in the current study. We used the Monte Carlo method to model the X-RAD320 X-ray unit based on the manufacturer provided information. The MC model was validated by comparing the MC calculated photon beam spectra with the results of SpekCalc software. The photon beam spectra were calculated for anode angles from 15 to 35 degrees. We also calculated the percentage depth doses for some angles to verify the impact of anode angle on depth dose. Additionally, the heel effect and its relation with anode angle were studied for X-RAD320 irradiator. Our results showed that the photon beam spectra and their mean energy are changed significantly with anode angle and the optimum anode angle of 30 degrees was selected based on less heel effect and appropriate depth dose and photon fluence per initial electron. It can be concluded that the anode angle of 30 degrees for X-RAD320 unit used by manufacturer has been selected properly considering the heel effect and dosimetric properties.Keywords
This publication has 11 references indexed in Scilit:
- Small animal radiotherapy research platformsPhysics in Medicine & Biology, 2011
- Monte Carlo simulator of realistic x‐ray beam for diagnostic applicationsMedical Physics, 2010
- A Monte Carlo Comparison of Three Different Media for Contrast Enhanced Radiotherapy of the ProstateTechnology in Cancer Research & Treatment, 2010
- Converging Stereotactic Radiotherapy Using Kilovoltage X-Rays: Experimental Irradiation of Normal Rabbit Lung and Dose–Volume Analysis With Monte Carlo SimulationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubesPhysics in Medicine & Biology, 2009
- Determining superficial dosimetry for the internal canthus from the Monte Carlo simulation of kV photon and MeV electron beamsAustralasian Physics & Engineering Sciences in Medicine, 2009
- LiF:Mg,Ti TLD response as a function of photon energy for moderately filtered x‐ray spectra in the range of 20–250 kVp relative toMedical Physics, 2008
- Characterization of the dose perturbation by stents as a function of x-ray beam energyCardiovascular Radiation Medicine, 1999
- Monte Carlo modelling of radiotherapy kV x-ray unitsPhysics in Medicine & Biology, 1999
- Orthovoltage radiation therapy treatment planning using Monte Carlo simulation: treatment of neuroendocrine carcinoma of the maxillary sinusPhysics in Medicine & Biology, 1997