Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter.
Open Access
- 18 April 2014
- journal article
- Vol. 7 (2) , 302-308
Abstract
To compare the RTVue spectral optical coherence tomography (SD-OCT), Sirius Scheimpflug-Placido topographer, Lenstar optical low coherence reflectometry (OLCR) and ultrasound pachymetry (USP) devices in terms of their agreement and repeatability of measuring central corneal thickness (CCT). In this prospective study, 50 eyes of 50 patients were included. Three repeated measures were obtained using SD-OCT, Scheimpflug-Placido topographer and USP and five measurements were determined with the OLCR. Bland-Altman plots were used to assess agreement among the instruments, and 95% limits of agreement (LoA) for each comparison were calculated. Intra-examiner repeatability was assessed using intraclass correlation coefficients (ICCs). The mean CCT by SD-OCT, Scheimpflug-Placido topographer, OLCR, and USP were 525.90±34.08 µm, 525.92±34.10 µm, 530.30±35.62 µm, and 543.50±37.11 µm respectively. All 4 modalities of CCT measurements correlated closely with each other, with Pearson correlation coefficients ranging from 0.977 to 0.995. The mean differences (and upper/lower LoA) for CCT measurements were -0.05±6.77 µm (13.3/-13.3) between SD-OCT and Scheimpflug-Placido topographer, 4.38±3.79 µm (11.8/-3.1) between OLCR and SD-OCT, 4.38±6.03 µm (16.2/-7.5) between OLCR and Scheimpflug-Placido topographer, 13.20±6.46 µm (25.9/0.5) between USP and OLCR, 17.59±6.76 µm (30.8/4.3) between USP and SD-OCT, and 17.58±8.13 µm (33.5/1.6) between USP and Scheimpflug-Placido topographer. Intra-examiner repeatability was excellent for all devices with ICCs>0.98. For most practical purposes, CCT measurements with the RTVue, Sirius and Lenstar can be used interchangeably. Although highly correlated, CCT measurement differences between USP and these 3 optical instruments can be significant depending on the clinical situation.Keywords
This publication has 40 references indexed in Scilit:
- Central Corneal Thickness Measurements With Different Imaging Devices and Ultrasound PachymetryCornea, 2013
- Corneal Thickness Measurement Using Orbscan, Pentacam, Galilei, and Ultrasound in Normal and Post-Femtosecond Laser In Situ Keratomileusis EyesCornea, 2012
- Relationship of Fuchs Endothelial Corneal Dystrophy Severity to Central Corneal ThicknessJAMA Ophthalmology, 2012
- Central Corneal Thickness Measurements: Using an Ultrasonic Instrument and 4 Optical InstrumentsCornea, 2011
- Assessment of Central Corneal Thickness Using OCT, Ultrasound, Optical Low Coherence Reflectometry and Scheimpflug PachymetryEuropean Journal of Ophthalmology, 2010
- Comparison of Fourier-Domain and Time-Domain Optical Coherence Tomography for Assessment of Corneal Thickness and Intersession RepeatabilityAmerican Journal of Ophthalmology, 2009
- Evaluating Central Corneal Thickness Measurements With Noncontact Optical Low-Coherence Reflectometry and Contact Ultrasound PachymetryAmerican Journal of Ophthalmology, 2006
- Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetryJournal of Cataract & Refractive Surgery, 2006
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- A clinical comparison of optical and ultrasonic pachometryActa Ophthalmologica, 1991